The text of a manual · part 10 of 37
Quadrus EZ Reader User's Manual, pages 91 to 100
Pages 91 to 100 of 366
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan EZ 6700 EX
Page 91
Symbologies
QR Code Usage:
Widely implemented in the automotive industry in Japan and throughout their worldwide supply chain.
Definition:
The QR Code is capable of handling numeric, alphanumeric, byte data as well as Japanese kanji and kana characters. Up to 7,366 characters (numeric data) can be encoded using this symbol. Therefore, less space is required to encode the same amount of data in the QR Code than in a conventional symbol, helping to reduce the size of a symbol and lower the paper costs. Three Position Detection Patterns in the symbol make omnidirectional ultra fast reading possible. QR Code has error correction capability. Data can be frequently be restored even if a part of the symbol has become dirty or been damaged.
Serial Cmd:
<K480,status>
Default:
Disabled
Options:
0 = Disabled
Quadrus EZ Reader User’s Manual
1 = Enabled
4-7
Page 92
Code 39
Code 39 Usage:
Code 39 is considered the standard for non-retail symbology.
Definition:
An alphanumeric symbology with unique start/stop code patterns, composed of 9 black and white elements per character, of which 3 are wide.
Serial Cmd:
<K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Check Digit Status (Code 39) Serial Cmd:
<K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Check Digit Output Status (Code 39) Usage:
Check digit Output, added to the symbol, provides additional security.
Definition:
When enabled, the check digit character is read and compared along with the symbol data. When disabled, symbol data is sent without the check digit. Note: With Check Digit Output and an External or Serial trigger option enabled, an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle.
Serial Cmd:
<K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
4-8
1 = Enabled
Quadrus EZ Reader User’s Manual
Page 93
Symbologies
Large Intercharacter Gap (Code 39) Usage:
Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since a large intercharacter gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap.
Definition:
When enabled, the reader can read symbols with gaps between symbol characters that exceed three times (3x) the narrow element width.
Serial Cmd:
<K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length Status (Code 39) Definition:
When enabled the reader will check the symbol length against the symbol length field. If disabled any length would be considered a valid symbol.
Serial Cmd:
<K470, status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length (Code 39) Usage:
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted.
Definition:
Specifies the exact number of characters that the reader will recognize (this does not include start and stop and check digit characters). The reader ignores any symbology not having the specified length.
Serial Cmd:
<K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
10
Options:
1 to 128
Quadrus EZ Reader User’s Manual
4-9
Page 94
Code 39
Full ASCII Set (Code 39) Usage:
Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) User must know in advance whether or not to use Full ASCII Set option. Since Full ASCII Set requires two code words to encode one character, it is less efficient.
Definition:
Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign and percent symbol. When Full ASCII Set is enabled, the reader can read the full ASCII character set, from 0 to 255.
Serial Cmd:
<K470,status,check digit status,check digit output,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
Default:
Disabled
Options:
0 = Disabled
4-10
1 = Enabled
Quadrus EZ Reader User’s Manual
Page 95
Symbologies
Code 128 Usage:
Code 128 is a smaller symbology useful in applications with tight spots and high security needs.
Definition:
A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge.
Serial Cmd:
<K474,status,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length Status (Code 128) Definition:
When enabled the reader will check the symbol length against the symbol length field. If disabled any length would be considered a valid symbol.
Serial Cmd:
<K474, status,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length (Code 128) Usage:
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted.
Definition:
It specifies the exact number of characters that the reader will recognize (this does not include start and stop and check digit characters). The reader ignores any symbol not having the specified length.
Serial Cmd:
<K474, status,fixed symbol length status,fixed symbol length>
Default:
10
Options: 1 to 128 Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.
Quadrus EZ Reader User’s Manual
4-11
Page 96
BC412
BC412 Usage:
It is widely used in the semi-conductor manufacturing and is particularly useful where speed, accuracy, and ease of printing are required.
Definition:
BC412 (Binary Code 412), a proprietary IBM symbology since 1988, is an alphanumeric symbol with a set of 35 characters, each encoded by a set of 4 bars in 12 module positions. All bars have a single width and it is the presence or absence of bars in each of the 12 module positions that makes it a binary code (hence the prefix “BC”). The symbology is bi-directional and self-clocking with a start and stop character.
Serial Cmd:
<K481,status,check digit output,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Check Digit Output (BC412) Usage:
Check digit Output, added to the symbol, provides additional security.
Definition:
When enabled, the check digit character is read and compared along with the symbol data. When disabled, symbol data is sent without the check digit. Note: With Check Digit Output and an External or Serial trigger option enabled, an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle.
Serial Cmd:
<K481,status,check digit output,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
4-12
1 = Enabled
Quadrus EZ Reader User’s Manual
Page 97
Symbologies
Fixed Symbol Length Status (BC412) Definition:
When enabled the reader will check the symbol length against the symbol length field. If disabled any length would be considered a valid symbol.
Serial Cmd:
<K481,status,check digit output,fixed symbol length status,fixed symbol length>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Fixed Symbol Length (BC412) Usage:
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted.
Definition:
Specifies the exact number of characters that the reader will recognize (this does not include start and stop and check digit characters). The reader ignores any symbology not having the specified length.
Serial Cmd:
<K481,status,check digit output,fixed symbol length status,fixed symbol length>
Default:
10
Options:
1 to 64
Quadrus EZ Reader User’s Manual
4-13
Page 98
Interleaved 2 of 5
Interleaved 2 of 5 Usage:
Definition:
Serial Cmd: Default: Options:
It is has been popular because it is the most dense symbology for printing numeric characters less than 10 characters in length; however, Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation. A dense, continuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check digit is highly recommended.) Important: You must set Symbol Length in order to decode I 2/5 symbols. <K472,status,check digit status,check digit output,symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Check Digit Status (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
It is typically not used but can be enabled for additional security in applications where the host requires redundant check digit verification. An error correcting routine in which the check digit character is added. <K472,status,check digit status,check digit output,symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Check Digit Output Status (Interleaved 2 of 5) Definition: Serial Cmd: Default: Options:
4-14
When enabled, a check digit character is sent along with the bar symbol data for added data security. <K472,status,check digit status,check digit output,symbol length #1,symbol length #2> Disabled 0 = Disabled 1 = Enabled
Quadrus EZ Reader User’s Manual
Page 99
Symbologies
Symbol Length #1 (Interleaved 2 of 5) Usage:
Definition:
Serial Cmd: Default:
Options:
With I 2/5, two symbol lengths can be defined. When using only one symbol length in an application, setting Symbol Length #2 to 0 (zero) to ensure data integrity is recommended. Allows user to define the symbol length. Because I 2/5 is a continuous symbology, it is prone to substitution errors. Hence, a symbol length must be defined and a bar code symbol must contain an even number of digits. Note: If a start, stop or check digits are used, they are not included in the symbol length count. <K472, status,check digit status,check digit output,symbol length #1,symbol length #2> 10 2 to 128, even. Since I 2/5 characters are paired, symbol length must be set to an even number. If Check Digit is enabled, add 2 to your symbol length. For example, if your symbol is 10 characters plus a check digit, then enable Symbol Length#1 for 12. Note: Typically, when printing an I 2/5 symbol with an odd number of digits, a 0 will be added as the first character. Note: If both Symbol Length # 1 and Symbol Length # 2 are set to 0, then I–2/5 will be variable.
Symbol Length #2 (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default:
Options:
If using a second symbol, a zero or any even symbol length from 2 to 64 may be specified. If not using a second symbol, set Symbol Length #2 to 0 to ensure data integrity. Allows user to define a second symbol length for Interleaved 2 of 5. <K472, status,check digit status,check digit output,symbol length #1,symbol length #2> 6 2 to 128, even. Since Interleaved 2 of 5 characters are paired, symbol length must be set to an even number. If Check Digit is enabled, add 2 to your symbol length. For example, if your symbol is 10 characters plus a check digit, then enable Symbol Length for 12. Note: Typically, when printing an I 2/5 symbol with an odd number of digits, a 0 will be added as the first character. Note: If both Symbol Length #1 and Symbol Length #2 are set to 0, then I–2/5 will be variable.
Quadrus EZ Reader User’s Manual
4-15
Page 100
Interleaved 2 of 5
Guard Bar (Interleaved 2 of 5) Note: Whenever Guard Bar is enabled, the presence of guard bars is required for decoding to take place. Usage:
It is useful when I 2 of 5 multisymbols are enabled to prevent false data output. This typically occurs with highly tilted or skewed symbols.
Definition:
A guard bar is a heavy bar, at least 2 times the width of the wide bar, surrounding the printed I 2 of 5 symbol and helping to prevent false reads.
Serial Cmd:
<K472, status,check digit status,check digit output status,symbol length #1,symbol length #2,guard bar>
Default:
Disabled
Options:
0 = Disabled
4-16
1 = Enabled
Quadrus EZ Reader User’s Manual