Page 131
I/O Parameters
Dimension 2 (2D Symbology Qualification) Definition:
Checks symbol dimension for a specified number of pixels. In the case of rectangular symbols, checks the shorter side.
Serial Cmd:
<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>
Default:
0
Options:
0 to 656 pixels
Dimension Tolerance (2D Symbology Qualification) Definition:
Sets the allowable deviation, in percentage, for symbol sizes specified in Dimension 1 or Dimension 1.
Serial Cmd:
<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>
Default:
10
Options:
0 to 100
Quadrus EZ Reader User’s Manual
5-15
Page 132
Bad/No Symbol Qualification
Orientation Mode (2D Symbology Qualification) Definition:
Sets the orientation value.
Serial Cmd:
<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>
Default:
Disabled
Options:
0 = Disabled 1 = Bad/no symbol output 2 = Object qualification 3 = Enable both
Disabled Decoded messages are output, but no attempt to qualify symbols or output Bad or No Symbol messages is undertaken.
Bad/No Symbol Output Checks first for decodes. If no symbol is decoded, checks for symbol orientation. If Orientation Value is satisfied, a Bad Symbol message is output. If not satisfied, outputs a No Symbol message.
Object Qualification Checks first for matches to symbol Orientation Value. If qualified, attempts to decode. If no decodes are found within the specified read cycle parameters, outputs a Noread message.
Enable Both Same as Object Qualification, except that if Orientation Value is satisfied but the symbol is not decoded, then a Bad Symbol message is output; if not satisfied, outputs a Bad Symbol message.
5-16
Quadrus EZ Reader User’s Manual
Page 133
I/O Parameters
Orientation Value Usage:
Instructs the reader to ignore symbols not in the specified orientation. Sets the orientation of the symbol, in degrees clockwise from the default 0 orientation. For Data Matrix symbols, sets the finder “L” pattern, with the adjacent being an example of the default 0 orientation:
Definition:
For QR Code, sets the locator pattern (three squares), with the adjacent being an example of the default 0 orientation: The other position settings will rotate clockwise from the defaults shown above.
Serial Cmd:
<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension mode,dimension 1,dimension 2,dimension tolerance,orientation mode,orientation value>
Default:
0
Options:
0 to 359
Note: A symbol’s orientation can miss the precise Orientation Value by several degrees and still be qualified. To be certain of the extent of the allowable tolerance, you should experiment with symbols in various orientations. In no case can they be more than 45° from the assigned orientation value and still be qualified.
Quadrus EZ Reader User’s Manual
5-17
Page 134
Read Duration Output
Read Duration Output Usage:
Useful in evaluating actual read cycle timing results, especially when initially setting up an application to determine maximum line speed that can be obtained based on the spacing between symbols.
Definition:
When enabled, the duration of the read cycle (in milliseconds) is appended to the symbol data. The read duration is the time from the beginning of the read cycle until data is output.
Read Duration Output Mode Serial Cmd:
<K706,status,separator>
Default:
Disabled
0 = Disabled 1 = Enabled Important: To measure the entire read cycle when in External Level trigger mode, set When to Output Symbol Data to End of Read Cycle. This output can measure over 49 days worth of duration; if exceeded, the “OVERFLOW” message will be output in place of the duration. Options:
Options:
0 = Disabled
1 = Enabled
Read Duration Output Separator Definition:
User-defined character that separates the symbol information from the Read Duration Output.
Serial Cmd:
<K706,status,separator>
Default:
[space character]
Options:
Any ASCII character
5-18
Quadrus EZ Reader User’s Manual
Page 135
I/O Parameters
Output Indicators The Quadrus EZ has a beeper and three LED arrays, as follows: 1. An X-pattern of blue LEDs in the front of the reader that project an X-shape for centering the field of view. 2. An array of green LEDs in the front of the reader that can be programmed to flash in response to user-defined conditions. 3. A row of five status LEDs on the side of the Quadrus EZ.
X-Pattern Usage:
Assists users in positioning and locating symbols in the center of the reader’s FOV.
Definition:
The user can control when the targeting system is ON or OFF and save this condition for power-on.
Serial Cmd:
<K750,green flash mode,x-pattern status,green flash duration>
Default:
Always Off
0 = Always OFF 1 = ON when NOT in the read cycle Options: 2 = ON when in the read cycle 3 = Always ON Important: The targeting system actuated by the EZ button or operational command overrides this setting.
Always OFF The X-pattern will remain OFF at all times unless overridden by the EZ button or operational command.
On When NOT In The Read Cycle The X-pattern is always ON except during the read cycle. If the EZ button or operational command overrides this setting, the X-pattern will remain on at all times.
On When in the Read Cycle The X-pattern will remain OFF except during the read cycle. If the EZ button or operational command overrides this setting, the X-pattern will remain on at all times.
Always ON The X-pattern is always ON.
Quadrus EZ Reader User’s Manual
5-19
Page 136
Output Indicators
Green Flash Mode Usage:
Used as a visual verification that a good read has occurred.
Definition:
An array of green LEDs in the front of the Quadrus EZ can be programmed to flash briefly in response to user-defined conditions, or if in Static Presentation mode, illuminate for a set period of time.
Serial Cmd:
<K750,green flash mode,x-pattern status,green flash duration>
Default:
Good Read
Options:
0 = Disabled 2 = Static Presentation 4 = Mismatch
1 = Good Read 3 = Match
Disabled Green flash LEDs are disabled.
Good Read (Green Flash) Green flash LEDs will flash for less than one second when a good read condition is meet or when matchcode is enabled and a match occurs.
Static Presentation (Green Flash) Static Presentation is used in conjunction with Continuous Read mode. When operating in Static Presentation mode, the LEDs will illuminate while the Quadrus EZ is searching for a symbol in Continuous Read mode. When a symbol is placed in the FOV and a good read occurs, the green LEDs will illuminate and stay on for the duration of time set in Green Flash Duration. Only one read will occur during that time unless more than one symbol is enabled in Number of Symbols. Note: If Static Presentation mode is selected but the reader is not in Continuous Read, the Green Flash will revert to Good Read mode. To use Static Presentation: 1. Enable Continuous Read. 2. Select the number of symbols. 3. Enable Static Presentation in Green Flash Mode. 4. Select the read time in Green Flash Duration. Note: Green Flash Duration values only take effect in Static Presentation Mode.
Match (Green Flash) Green flash LEDs will flash for less than 1 second when a match condition is met. If multisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is disabled, then this mode will activate the LED's on a good read.
Mismatch (Green Flash) Same as On Match except it illuminates on a mismatch.
5-20
Quadrus EZ Reader User’s Manual
Page 137
I/O Parameters
Green Flash Duration Usage:
A visual verification that a good read has occurred.
Definition:
When a good read occurs, the Green flash LED's will illuminate and stay on for the time set for the Green Flash Duration value.
Serial Cmd:
<K750,green flash mode,x-pattern status,green flash duration>
Default:
100 (1 second)
Options: 0 to 65535 (in 10mS increments) Note: Green Flash Duration values only take effect in Static Presentation Mode.
Beeper Usage:
An audible verification that either a good read or a noread has occurred.
Definition:
A beep is emitted either after each good read or noread.
Serial Cmd:
<K702,beeper status>
Default:
Good Read
0 = Disabled 1 = Good Read 2 = Noread Note: Beeper will also sound if any of the following occur: • the reader is defaulted • a send/save command from ESP or an Exit command from any embedded menu • at the conclusion of a calibrate procedure • a <Z>, <Zp>, <Zd>, or <K701,1> command is sent Options:
Quadrus EZ Reader User’s Manual
5-21
Page 138
Output Indicators
LED Configuration Mode Usage:
Useful as a visible verification of read rates and bar code quality.
Definition:
Determines the mode in which the status LEDs on the side of the Quadrus EZ operate.
Serial Cmd:
<K737,LED mode,ISO/IEC 15415 grade,DPM grade>
Default:
Standard
Options: 0 = Standard 1 = ISO/IEC Grade 2 = DPM Grade In both ISO/IEC 15415 and DPM grade modes the LEDs represent the grade of the first Data Matrix symbol read in a read cycle. The parameter to be graded is set in the ISO/IEC 15415 Grade or DPM Grade options. For example, to program the LEDs to indicate the ISO/IEC 15415 print growth grade, set LED Mode to ISO/IEC 15415 Grade and set ISO/IEC 15415 Grade to Print Growth. If all the LEDs from 20% to 100% were illuminated, the read result would be a grade A; if only the 20% LED were illuminated, the result would be a grade F.
Standard (LED Configuration) In Standard mode the STATUS LED indicates read cycle status and the GOOD READ LED illuminates upon a good read at the end of a read cycle. In a read rate test, these LEDs represent the percentage of good reads per images captured.
ISO/IEC 15415 Grade (LED Configuration) Usage:
Provides visual validation of specific ISO/IEC 15415-related features.
Definition:
Determines which ISO/IEC 15415 feature the reader will grade via the LEDs.
Serial Cmd:
<K737,LED mode,ISO/IEC 15415 grade,DPM grade>
Default:
Final Grade
Options:
0 = Final Grade 2 = Print Growth
1 = Symbol Contrast 3 = Unused EEC
DPM Grade (LED Configuration) Usage:
Provides visual validation of specific DPM-related features.
Definition:
Determines which DPM feature the reader will grade via the LEDs.
Serial Cmd:
<K737,LED mode,ISO/IEC 15415 grade,DPM grade>
Default:
Final Grade
Options:
0 = Final Grade 2 = Dot Ovality
5-22
1 = Dot Center Offset 3 = Angle of Distortion
Quadrus EZ Reader User’s Manual
Page 139
I/O Parameters
Serial Verification Allows the user to verify configuration command status.
Serial Command Echo Status
Usage:
This command is useful in removing any doubt about the reader’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K701,1, START> is entered, the reader will echo back <K701, SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore it is rejected and the existing “SOM” message is echoed back and remains the preamble message.
Definition:
When enabled, a configuration command received from the host is echoed back to the host with the resultant settings.
Function:
If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change.
Serial Cmd:
<K701,serial command echo status,serial command beep status,control/ hex output>
Default:
Disabled
Options:
0 = Disabled
Host
Reader
1 = Enabled
Serial Command Beep Status Usage:
Used to audibly verify the acceptance and validity of a command.
Definition:
Causes the reader to beep once whenever a K command is entered to indicate that the command was accepted and processed.
Function:
If an invalid command is entered, the reader beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.
Serial Cmd:
<K701,serial command echo status,serial command beep status,control/ hex output>
Default:
Disabled
Options:
0 = Disabled
Quadrus EZ Reader User’s Manual
1 = Enabled
5-23
Page 140
Serial Verification
Control/Hex Output Usage:
Useful for viewing settings with binary characters when using serial command on a terminal.
Definition:
Determines the response to an Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a nondisplayable character. For example, a carriage return will be shown as the two characters: ^M. When set to Hex, the output is the hex character.
Serial Cmd:
<K701,serial command echo status,serial command beep status,control/ hex output>
Default:
Control
Options:
0 = Control
5-24
1 = Hex
Quadrus EZ Reader User’s Manual