Spec sheet · Microscan
Microscan 6500 Spec Sheet
Spec sheet2 pagesPDF 114 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page product sheet for the Microscan Quadrus Standard static Data Matrix reader, sold in FIS-6500 reader options for different minimum element sizes. It describes auto calibration, the illumination database and the ESP setup software, then lists the specifications, read options and connectors.
- Device
- Fixed-mount static Data Matrix reader combining optics, lighting and decoder in one sealed housing p. 1
- Symbology
- Data Matrix ECC 0-200 p. 1
- Reader options
- FIS-6500-0004 5 mil, FIS-6500-0005 7.5 mil, FIS-6500-0006 10 mil, FIS-6500-0007 15 mil, FIS-6500-0001 20 mil (minimum element size) p. 2
- Field of view
- 20 mil reader 1.67" x 1.25" at 5"; 5 mil reader 0.4" x .3" at 3"; 10 mil reader .7" x .53" at 4" p. 2
- Symbol sizes
- Square 10 x 10 to 144 x 144; rectangular 8 x 18 to 16 x 48 (rows x columns) p. 2
- Communication
- RS-232, RS-422, RS-485; point-to-point, polling, multidrop and RS-232 daisy chain protocols p. 2
- Power
- 10 to 28 VDC p. 2
- Connectors
- Host: 25-pin D-Subminiature; trigger and power: Switchcraft EN3 p. 2
- I/O
- Three programmable outputs and two programmable inputs p. 1
- Imager and light
- CCD array, 659 x 494 pixels, progressive scan; high output LEDs with software-adjustable strobe time p. 2
- Read parameters
- Pitch ±30°, skew ±30°, tilt 360°; 300 reads per minute p. 2
- Environment
- IP65 die-cast aluminum housing; 0° to 40°C (32° to 104°F); 5% to 90% humidity non-condensing; 17.6 oz. (498 g) p. 1, 2
- Setup software
- Windows-based ESP (Easy Setup Program) for match code, triggering, I/O and image evaluation p. 1
- Illumination
- Auto calibration of illumination; up to twenty stored illumination settings; pre-calibrated focal points p. 1
What this sheet walks you through
- Choosing a reader option by minimum element size p. 2
- Wiring the 25-pin host connector, trigger and power connectors p. 2
- Reading the status lights p. 2
Good to know
- Specifications are for typical performance at 25° Celsius with grade A labels and may vary at high temperatures. p. 2
Questions this sheet answers
What power does the Microscan Quadrus 6500 reader need?
10 to 28 VDC, through the power connector or the host connector. p. 2
Which Microscan FIS-6500 reader reads 5 mil Data Matrix codes?
FIS-6500-0004, the 5 Mil Reader, with a 0.4" x .3" field at 3". p. 2
What does the green LED on the Quadrus reader mean?
In normal operation it lights when a label is decoded and stays on until the next trigger; in continuous read it flashes for each good read. p. 2
What serial interfaces does the Microscan Quadrus Standard have?
RS-232, RS-422 and RS-485 on a 25-pin D-Subminiature host connector. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Data Matrix Reader The Quadrus™ standard model has allowed many companies to realize the benefits of using space efficient 2D Data Matrix code by offering a user friendly and cost effective reading solution. When compared to related technologies, Quadrus™ wins over vision systems by being more cost effective and easier to use. Quadrus also wins over hand-held readers by offering better read quality. Plus, since Quadrus is a fixed unit, no operator is required. Quadrus™ is practically as simple as point-click-and-go, when using the combined features of Auto Calibration, fixed focal point and the Image Processing Database. This can be extremely helpful for those who laser etch codes directly onto parts, which can produce varying contrast levels. Regardless of your print method, Quadrus™ is the universal reading solution for any static application requiring data matrix.
QUADRUS™ STANDAR
Static Data Matrix Reader
D
Auto Calibration: Automates the process of obtaining the nominal illumination settings. If Quadrus™ is unable to read a code, auto calibrate automatically searches through the settings to find the best possible combination for the symbol. No user adjustment is required. Image Processing Database: This allows the user to pre-set and store up to twenty illumination settings. This feature ensures readability for symbols within various print qualities and contrasts.
Calibrated Focal Points: Quadrus eliminates focusing by having pre-calibrated focal points. Technical operators will not need to reconfigure the unit if it is disturbed. Real Time Control Features: Quadrus™ has three programmable outputs and can accept two programmable inputs, offering the utmost in I/O versatility. Symbology: The Quadrus™ reads Data Matrix ECC 0-200 symbology. This symbology is highly secure and readable even when codes are torn, damaged, or in poor condition. ESP™ Software: A standard feature of the Quadrus™ is Microscan’s Easy Setup Program, a user-friendly configuration and installation software. The Windows-based ESP™ software provides simple setup control commands for configuring parameters such as match code routines, triggering, real-time input/output controls, and image evaluation tools. Service Options:
- Installation assistance
- Service agreements
- Training
- On-site support
- Extended Warranty
Fully-Integrated: Quadrus™ combines the optical components, lighting and decoder within a compact, sealed IP65 rated enclosure. IP65 Enclosure Rating: Quadrus’ internal circuitry and components are protected against harsh industrial environments by a die-cast aluminum housing which is sealed to IP65 standards (industrial rating for dust and moisture protection).
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
QUADRUS STANDARD™ STATIC DATA MATRIX READER Specifications and Options
MECHANICAL
QUADRUS STANDARD™ READER CHART 2.96" 7.52 cm
Data Matrix symbol sizes range from 10 x 10 to 144 x 144 (rows x columns) for square symbols and from 8 x 18 to 16 x 48 for rectangular symbols. Contact Microscan for full read specifications.
Reader Options 2.27" 5.77cm
Millimeter size denotes the minimum size the unit can read.
Front
1.00" 2.54 cm
(4 pls) mounting 0.225" (0.57 cm) thread depth
0.97" 2.5 cm
FIS-6500-0001: The 20 Mil Reader (minimum element size) 1.67" x 1.25" at 5" (42.4 mm x 31.7 mm at 127mm) FIS-6500-0004: The 5 Mil Reader (minimum element size) 0.4" x .3" at 3" (10.1 mm x 7.6 mm at 76.2 mm)
Data Matrix Codes* N = num, A = alpha
10 x 10, 5 mil Capacity: N:6, A:3
16 x 16, 7.5 mil Capacity: N:24, A:16
FIS-6500-0005: The 7.5 Mil Reader (minimum element size) .55" x .4" at 4" (13 mm x 10.1 mm at 101 mm) 5.14" 13.06 cm
Bottom
2.97" 7.54 cm
FIS-6500-0006: The 10 Mil Reader (minimum element size) .7" x .53" at 4" (17.7 mm x 13.4mm at 101 mm) FIS-6500-0007: The 15 Mil Reader (minimum element size) .975" x .75" at 4" (24.7 mm x 19.0 mm at 101 mm)
0.81" 2.07 cm
24 x 24, 10 mil Capacity: N:72, A:52
36 x 36, 15 mil Capacity: N:172, A:127
- Scale is 1:1. Codes are for illustrative purposes only.
Back
PIN ASSIGNMENTS
Host connector Power connector
Trigger connector
ENVIRONMENTAL Weight: 17.6 oz. (498 g) Housing: IP65 Operating temperature: 0° to 40°C (32° to 104°F) Humidity: 5% to 90% (non-condensing)
LIGHT SOURCE Type: High output LEDs Software-adjustable strobe time
LIGHT COLLECTION Type: CCD array, 659 x 494 pixels progressive scan, square pixel
COMMUNICATION PROTOCOLS RS-232, RS-422, RS-485 Point-to-point, Point-to-point w/RTS/CTS, Point-to-point w/XON/XOFF, Point-to-point w/RTS/CTS & XON/XOFF, Polling Mode D, Multidrop, User Defined, User Defined Multidrop, RS-232 Daisy Chain
SYMBOLOGIES READ Data Matrix ECC 0–200 Contact Microscan for details about other symbologies.
READ PARAMETERS Pitch: ±30° Skew: ±30° Tilt: 360° Read Rate: 300 reads per minute
ELECTRICAL Power requirement: 10 to 28 VDC
Host Connector 25-pin D-Subminiature
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Function Signal ground Transmit data RS-232 (out) Receive data RS-232 (in) Request-to-send (out) Clear-to-send (in) Out-1 (out) Signal ground Out-2 (out) Strobe (out) Trigger (in) Default (in) In-1 (in) RXD 485 + (in) TXD 485 – (out) Noread/Out-3 (out) RXD 485 – (in) Power ground Power 10 to 28 VDC (in) TXD 485 + (out) Aux transmit data RS-232 (out) In-2 (in) Ground Aux receive data RS-232 (in) +12 VDC (out) New master (in)
STATUS LIGHTS Yellow Power LED: On power-on Green Status LED: Normal operations: illuminates whenever a bar code label is decoded and remains on until a new trigger occurs. Continuous Read or Continuous Read 1 Output: flashes for each good read
Trigger Connector Switchcraft EN3
Power Connector Switchcraft EN3
Function Trigger (in) +12 VDC (out) Ground Strobe (out)
Function Power 10 to 28 VDC (in) Power ground
SAFETY CERTIFICATIONS Designed for: FCC, TüV, CE, cUL, UL ISO 9001/Cert. No. US96/0465 ©2002 Microscan Systems, Inc. 02/02 Specifications subject to change. Product specifications are given for typical performance at 25° Celsius (77° Fahrenheit) using grade A labels. Some performance characteristics may vary at high temperatures or other environmental extremes.
Warranty, One year limited warranty on parts and labor. Extended warranty available.
Microscan Systems, Inc. Tel 800 251 7711 / Fax 425 226 8250 Microscan Europe Tel 31 172 423360/ Fax 31 172 423366 Microscan Asia Pacific R.O. Tel 65 846 1214 / Fax 65 846 4641 Part of a full range of sales tools available from our web site:
www.microscan.com
Tech Support: helpdesk@microscan.com Product Information: info@microscan.com