Page 81
Profile Card Configuration
Mode 4: Preamble, Postamble Mode Switches
= On = Off
Data Switches Preamble
Postamble
1
2 Disabled
Disabled
Enabled
Enabled
Mode 5: Protocol, Host Port RS-422 = On
Mode Switches
= Off Data Switches Protocol
RS-422
123
4 Point-to-Point
Disabled
Point-to-Point with RTS/CTS
Enabled
Point-to-Point with XON/XOFF
4–Profile Card.
Point-to-Point with RTS/CTS & XON/XOFF Polling Mode D Multidrop User Defined User Defined Multidrop
MS-3000 Single Head Decoder User’s Manual
4-7
Page 82
Chapter 4
Profile Card Configuration
Operations Settings Mode 6: Aux Port Mode Switches
= On = Off
Data Switches Aux port mode:
12 Disabled Transparent Half Duplex Full Duplex Mode 7: Triggering Mode, End of Read Cycle Mode Switches
= On
4–Profile Card.
= Off Data Switches Triggering Mode
End of Read Cycle
123
45 Continuous Read
Timeout
Continuous Read 1 Output
New Trigger
External Level
Timeout & New Trigger
External Edge Serial Data Serial Data & Edge
4-8
MS-3000 Single Head Decoder User’s Manual
Page 83
Profile Card Configuration Mode 8: Bar Code Output, When to Output, External Trigger Polarity, Match Code, Noread Message Mode Switches
= On = Off
Data Switches Bar Code Output
When to Output
External Trigger Polarity
Match Code
Noread Message
1
2
3
4
5
Disabled
As Soon as Possible
Negative
Disabled
Disabled
Enabled
End of Read Cycle
Positive
Enabled
Enabled
Mode 9: Timeout Mode Switches
= On = Off
Since the number of profile card settings is limited to 255, trigger timeouts entered from the profile card can only affect a range from 0.1 seconds to 25.5 seconds, in tenths of a second. To set Timeout, multiply the desired number of seconds for timeout by 10 and enter the result in binary format.
MS-3000 Single Head Decoder User’s Manual
4-9
4–Profile Card.
See mode 1 for switch settings for timeout ranges from 0.1 seconds to 5 seconds. (Although not shown for mode 1, switches 7 and 8 are OFF for 1 through 50.) See “Binary Calculations” on page 4-13 for timeout ranges from 5.1 seconds to 25.5 seconds.
Page 84
Chapter 4
Profile Card Configuration Mode 10: Serial Trigger Character = On
Mode Switches
= Off
You can define the Serial Trigger Character with an ASCII character of your choice, or you can use the samples provided below. To use other ASCII characters, see the ASCII table in appendix B for characters and their corresponding decimal values. See mode 1 for values from 1 to 50, or “ Binary Calculations” on page 4-13 for decimal values from 51 to 255. Data Switches
ASCII Decimal Number
Sample Serial Trigger ASCII Characters
29
^]
49
1
65
A
90
Z
12345678
Mode 11: Number of Reads Before a Good Decode Mode Switches
= On = Off
4–Profile Card.
The range for Number of Reads before a Good Decode is 1-31. See mode 1 for switch settings.
4-10
MS-3000 Single Head Decoder User’s Manual
Page 85
Profile Card Configuration
Code Types Settings Mode 12: Code 39, Codabar, I 2 of 5, UPC, Code 128, Narrow Margins
Enabling data switches 1 through 5 will autodiscriminate for all code types. Mode Switches
= On = Off
Data Switches Code 39
Codabar
I 2 of 5
UPC
Code 128
Narrow Margins
1
2
3
4
5
6
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
User Outputs Settings Mode 13: Beeper Volume, Beeper Enable, Beeper Speed Mode Switches
= On = Off
Beeper Enable
Beeper Speed
123
45
6
Level 1
Disabled
Fast
Level 2
On Good Read
Slow
Level 3
On Noread
4–Profile Card.
Data Switches Beeper Volume
Level 4 Level 5
MS-3000 Single Head Decoder User’s Manual
4-11
Page 86
Chapter 4
Profile Card Configuration Mode 14: Relay Driver, Full Screens, Good/Bad Polarity, New Master Pin, Laser On/Off, Reverse Video Mode Switches
= On = Off
Data Switches Relay Full Driver Screens
Good/Bad Polarity
New Master Pin
Laser On/Off
Reverse Video
12
4
5
6
7
3 Good Match
Disabled
Negative
Disabled
Disabled
Disabled
Mismatch
Enabled
Positive
Enabled
Enabled
Enabled
Noread
4–Profile Card.
Mismatch or Noread
4-12
MS-3000 Single Head Decoder User’s Manual
Page 87
Profile Card Configuration
Binary Calculations Data switch settings for values 51 to 255 must be determined by the user with binary calculation. (Specifically, the timeout values for 51 to 255 in mode 9 and various serial trigger character selections in mode 10.) The eight data switches on the profile card represent the eight data bits that define any number from 0 to 255 in binary format. To convert a number to its binary equivalent: 1. Determine which decimal equivalent (1, 2, 4, 8, 16, 32, 64, 128) is the largest number not exceeding the number to convert. 2. Put a one (1) above that number to indicate an ON position. For example, table 4-2 shows the calculation process for the number 250. The first one (1) is placed in the eighth bit column over the number 128, since that is the largest possible decimal equivalent to use. Table 4-2 Calculating Binary Conversion Data Switches
1
2
3
= On
4
5
6
7
8
Data Switches (bit representation) Data Switch Settings
1
1
1
1
1
1
Binary Code
2
10 26 58 122
Remainder Numbers
250 2
4
8
16 32 64 128
<--- Number to Convert Decimal Equivalent
3. Subtract the decimal equivalent from the original number. 4. Place the remainder above the next largest decimal equivalent that does not exceed the remainder number. 5. Put a one (1) above that number. 6. Continue this process until the remainder equals zero (0), as follows: 250 -128=122, -64=58, -32=26, -16=10, -8=2, -2=0
OFF positions on the data switches result from: • Decimal equivalent numbers passed over because they are greater than the remainder (the third bit in table 4-2), • Decimal equivalent numbers not used because the formula has terminated with a remainder of zero (0) (the first bit in table 4-2). MS-3000 Single Head Decoder User’s Manual
4-13
4–Profile Card.
1
= Off
Page 88
Chapter 4 Profile Card Configuration se} o © O 2 e fe) = am +
4-14 MS-3000 Single Head Decoder User’s Manual
Page 89
Chapter
5
Operational Commands Chapter Contents Summary of Operational Commands ...........................................5-2 Program Management Commands...............................................5-3 Device Control Commands...........................................................5-3 Code Type Commands.................................................................5-4 Counter Commands......................................................................5-4 Test Commands ...........................................................................5-5 Status Commands ........................................................................5-5 Master Label Commands..............................................................5-5
This chapter describes of all serial operational commands and their functions. See table 5-1 on page 5-2 for quick reference. On-line serial operational commands are sent from the host to the decoder to carry out routine operations “on the fly” as distinguished from serial configuration commands which are generally used in initial setup. 1 Operational commands are preceded by a < left angle bracket symbol (unless redefined by Command Start Character command) and followed by a > right angle bracket symbol. 2
2. Command start character by default is a left angle bracket, <. It may be redefined by menu or serial command. However, the end character, a right angle bracket, >, cannot be changed. MS-3000 Single Head Decoder User’s Manual
5-1
4–Operations
1. The decoder will only recognize a <D> serial command (Enter Menu Configuration Program) from an auxiliary terminal.
Page 90
Chapter 5
Operational Commands
Summary of Operational Commands Table 5-1 Summary of Operational Commands
Command Type Program Management
Device Control
Code Types
Counters
Test
Status
4–Operations
Master Label
Command
Result
<A>
Software Reset (does not save for power-on)
<D>
Enter Configuration Mode
<Z>
Save Configuration for Power-on
<Bdata>
Echo Data to Aux Monitor
<H>
Enable Laser Scanning
<I>
Disable Laser Scanning
<L>
Host Relay Driver
<P>
Autodiscriminate All Codes
<Q>
Enable Code 39 Only*
<R>
Enable Codabar Only*
<S>
Enable I 2 Of 5 Only*
<N>
Noread Counter
<O>
Noread Counter Reset
<T>
Trigger Counter
<U>
Trigger Counter Reset
<V>
Match Code (or Good Read) Counter
<W>
Match Code Counter Reset
<X>
Mismatch Counter
<Y>
Mismatch Counter Reset
<C>
Enter Read Rate Test
<m>
Enter Scan Rate Test
<J>
Exit Read Rate or Scan Rate Test
<#>
Display Software Part Number
<!>
Display Checksum of EPROM
<E>
Enable Match Code Option*
<F>
Disable Match Code Option*
<G>
Store Next Label Scanned as Master Label
<)XXXX)>
Download Master Label Information
<)>
Request Master Label Information
<))>
Delete Master Label Information
* Can also be accomplished in configuration menu and serial configuration command.
5-2
MS-3000 Single Head Decoder User’s Manual