Page 71

User Outputs Commands

Serial Command Verification Format: <KSserial command echo status,serial command beep status,control/hex output> serial command echo status: 0 = Disabled 1 = Enabled serial command beep status: 0 = Disabled 1 = Enabled control/hex output: 0 = Control 1 = Hex

Example: To enable Serial Command Echo Status and Beep Status, and Hex output, enter <KS1,1,1>

Serial Command Echo Status When enabled, serial configuration commands (“K” commands) will be processed and the new string for that command will be echoed back to the host. (See “Serial Command Echo,” on page 2-32 for more details.)

Control/hex Output Determines the echoed display of a serial status request when ASCII characters with control characters are entered in a serial configuration command. When set to Control, the echoed output includes a control character as shown in the “Ctrl” column of Table A-2, “ASCII Table with Control Characters,” on page A-3. When set to Hex, the output is the actual character entered, for example the preamble command <Ke,,CR> echoes back as >Ke,, because in Hex mode the carriage return key acts on the command. In Control mode <Ke,,^M> is returned.

User Output Status Request Format: <KX?> Returns status of each command in the User Output group.

Reverse Video Format: <KDstatus> status: 0 = Disabled 1 = Enabled Example: To enable Reverse Video, enter <KD1>. MS-3000 Single Head Decoder User’s Manual

3-15

3–Serial Config.

Beep on Serial Command When enabled, the decoder beeps once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the decoder beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.

Page 72

Chapter 3

Serial Configuration

Good/Bad Polarity Format: <Kwpolarity> polarity: 0 = Negative 1 = Positive Pin 6 and 8 on host connector, and pin 2 on trigger connector. Example: To change Good/Bad Polarity to Negative, enter <Kw0>.

Good/Bad Pulse Width Format: <Kxrelay pulse> duration of relay pulse: Any number from 0 to 255.

Default is 5 (50 ms).

Pin 6 and 8 on host connector, and pin 2 on trigger connector. Example: To set Good/Bad Pulse Width to 600 ms, enter <Kx60>.

Command Start Character 3–Serial Config.

Format: <KEcommand start character> command start character: Any ASCII character. Default is <. Example: To change Command Start Character to a colon (:), enter <KE:>. Note: Subsequent commands must start with a colon (:). For example, enter :D> to access the menu, or :KE<> to change back to the default character.

User Outputs Status Request Format: <KX?> Returns status of each command in the group.

3-16

MS-3000 Single Head Decoder User’s Manual

Page 73

Raster Setup Commands

Raster Setup Commands Format: <KRstatus,top offset,bottom offset,motor speed> status: top offset in degrees: 0 = Disabled Any number from 0 to 45. Default is 0. 1 = Enabled bottom offset in degrees: Any number from 0 to 45. Default is 45.

motor speed (in sweeps per second): Any number from 0 to 135. Default is 14.

Example: To set the raster arc to 35º and the raster motor speed to 10 sweeps per second, enter <KR1,5,40,10>.

3–Serial Config.

MS-3000 Single Head Decoder User’s Manual

3-17

Page 74 read from a scan by OCR; it may hold reading errors

Chapter 3 Serial Configuration

7) = iS ° 1S) © = o at o

3-18 MS-3000 Single Head Decoder User’s Manual

Page 75

The text of this page cannot be shown here; see it in the PDF.

Page 76

Chapter 4

Profile Card Configuration

Summary of MS-3000 Modes Table 4-1 Profile Card Mode Descriptions

Mode

0

1 2

3 4 5 6 7

4–Profile Card.

8

9 10 11 12 13

14

4-2

Parameter

Function

Write-to-Device Downloads (copies) all of the configuration parameters from the Function profile card to the connected decoder. Uploads configuration data from the volatile RAM of the decoder to Read Function the non-volatile RAM of the profile card. Default Sets unit to the default configuration settings. Menu Enters the menu program while decoder is in polled mode. Combines the write function from mode 0 with the address function of Write & Assign Address mode 2. Downloads a multidrop address as well as all of the configuration parameters in the profile card. Assigns user-selected multidrop address to the decoder by using Assign Multidrop data switches 1-6. Binary representation of the multidrop address is Address used (the range is 1 to 50). Baud Rate Defines Baud Rate for the host port. Parity Defines Parity for the host port. Stop Bits Defines Stop Bits for the host port. Data Bits Defines Data Bits for the host port. Preamble Enables/disables Preamble. Postamble Enables/disables Postamble. Protocol Defines the communications protocol. RS-422 Enables/disables RS-422. Aux Port Sets Aux. Port operation mode. Triggering Mode Defines Triggering Mode. End of Read Cycle Defines End of Read Cycle. Bar Code Output Enables/disables Bar Code Output. When to Output Defines the conditions for When to Output. External Trigger Polarity Defines External Trigger Polarity (negative/positive). Match Code Enables/disables Match Code. Noread Message Enables/disables Noread Message. Sets the trigger timeout value. The range is 1-255 for corresponding Timeout in 10 ms inc. values of 0.1 to 25.5 seconds. Serial Trigger Assigns the Serial Trigger Character. (See the ASCII table on page Character A-3 for decimal values and corresponding characters.) Number of Reads Sets the number of reads for a good decode from 1-31. Narrow Margins Enables/disables Narrow Margins for all code types. Code Types Enables individual bar code types or Autodiscriminate. Beeper Volume Sets the beeper volume. Beeper Sets the conditions when the beeper is emitted. Relay Driver Defines the mode selection for programmable output. Full Screens Enables/disables Full Screens. Good/Bad Polarity Sets the Polarity of output pulses. New Master Pin Enables/disables New Master Pin. Laser On/Off Enables/disables Laser On/Off. Reverse Video Enables/disables Reverse Video.

MS-3000 Single Head Decoder User’s Manual

Page 77

The text of this page cannot be shown here; see it in the PDF.

Page 78

Chapter 4

Profile Card Configuration

General Settings Mode 0: Write, Read, Default, Menu Mode Switches

= On = Off

Data Switches

1 2 3 4 Write Read Default Menu

4–Profile Card.

Note: Unintentional defaults may occur when using the profile card‘s write functions (modes 0 and 1) to copy configuration changes from versions -26 and earlier to versions -27 and later (and vice versa), and when copying from versions -27 through -31 to versions -32 and later (and vice versa) of Microscan standard firmware. 1 To solve, you can change all EPROMs to the same firmware version, use a separate profile card for each version group, or use a single profile card to first make all configuration copy changes within one group (those with all earlier or all later versions) and then, after individually changing the settings in one decoder of the second group, copying them to the other decoders in that group.

1. The firmware number is 35-213001-XX for the MS-3000 single head decoder. The XX is substituted here for the version number. The firmware version can be found on a label on the EPROM, displayed in the heading of the Main menu in the Configuration program, or on later versions, displayed by invoking the <#> serial operational command. You can also call-in the serial numbers of the decoders to Microscan to get the firmware versions issued with those decoders.

4-4

MS-3000 Single Head Decoder User’s Manual

Page 79

Profile Card Configuration Mode 1: Write Configuration and Assign Address Mode Switches

= On = Off a

Data Switches Address

1 2 3 4 5 6

1

Address

Address

Address

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6 27

40

2

15

28

41

3

16

29

42

4

17

30

43

5

18

31

44

6

19

32

45

7

20

33

46

8

21

34

47

9

22

35

48

10

23

36

49

11

24

37

50

12

25

38

13

26

39

4–Profile Card.

14 a. Use these switch settings for mode 2, 9, 10, and 11.

MS-3000 Single Head Decoder User’s Manual

4-5

Page 80

Chapter 4

Profile Card Configuration

Communications Settings Note: Changes in Communications parameters or assigning an address to the decoder can cause loss of communications with the configuration terminal when you exit the menu program (whether or not changes are saved for power-on). Mode 2: Address Mode Switches

= On = Off

Address selection for mode 2 is identical to mode 1. See mode 1 for switch settings. Mode 3: Host Port Baud Rate, Parity, Stop Bits, Data Bits Mode Switches

= On = Off

Data Switches Baud Rate Parity

Stop Bits

Data Bits

123

6

7

45 600

None

One

Seven

1200

Even

Two

Eight

2400

Odd

4–Profile Card.

4800 9600 19200 38400

4-6

MS-3000 Single Head Decoder User’s Manual