Page 11

Appendix A (Continued) Operational Depth of Scan Field

203mm to 457mm (8" to 18")

Scan Speed

Model 870 1250 scan lines per second Model 875: 450 scan lines per second

Scan Pattern

Model 870: Omnidirectional (20 interlocking lines) Model 875: 6-line raster

Indicators Beeper Operation

LED: green=on ready to scan; red=good read Selection of 3 tones for “Good Read”

Maintenance Required

Clean window periodically

Decode Capability

Autodiscriminates

System Interfaces

RS-232C; Light Pen Emulation; OCIA

Optional Interfaces

Opto coupled 6 amp US and Canada, 5 amps EEA countries TRIAC output; object sensor input

Print Contrast

35% minimum reflectance difference

Roll, Pitch, Yaw

360°, 60°, 60°

Environmental Storage Temperature

-40°C to 60°C (-40°F to 140°F)

Operating Temperature

0°C to 35°C (32°F to 95°F)

Humidity

5% to 95% relative humidity, non-condensing

Light Levels

Up to 3200 foot candles - works in direct sun

Ventilation

None required

Shock

100g for 1ms

ESD

8kV IEC 801-2

Contaminants

Protects against dust, falling dirt, and dripping non-corrosive liquid

Specifications subject to change without notice.

8

Page 12

Appendix B Version A1 Pin Assignments for the Mil spec Connector Each TECH 8 scanner has a 19-pin male Mil spec connector that is found on the side of the unit. To connect the scanner to the host device, use a communication cable with a female Mil spec connector. The communication cable may include a power transformer or it may be designed to draw power directly from the host device. This item can be ordered when the scanner is purchased. The following is a list of pin assignments for Version A1 scanners. The communication protocols for Version A1 are RS-232 and OCIA. The pin numbers are impressed on the male Mil spec connector. For easier reference, refer to Figure 3 for pin locations.

PIN

FUNCTION

A B C D E F G H J K L M N P R S

R Data RTS Output Signal Ground CTS Input R Data Return RS-232 Output Clock In Clock In Return Clock Out Shield Ground DTR Input Clock Out Return Power to Scanner + 24 VDC Earth Ground Power Ground RS-232 Input

Figure 3

9

Page 13

Appendix B (Continued) Version A15 Pin Assignments for the Mil spec Connector Each TECH 8 scanner has a 19-pin male Mil spec connector that is found on the side of the unit. To connect the scanner to the host device, use a communication cable with a female Mil spec connector. The communication cable may include a power transformer or it may be designed to draw power directly from the host device. This item can be ordered when the scanner is purchased. The following is a list of pin assignments for Version A15 scanners. The communication protocol for Version A15 is light pen emulation. The pin numbers are impressed on the male Mil spec connector. For easier reference, refer to Figure 4 for pin locations.

10

PIN

FUNCTION

A B C D E F G H J K L M N P R S

R Data Light Pen Data Output Signal Ground Light Pen Source + 5 VDC R Data Return RS-232 Output Clock In Clock In Return Clock Out Shield Ground DTR Input Clock Out Return Power to Scanner + 24 VDC Earth Ground Power Ground RS-232 Input

Figure 4

Page 14

Appendix C Warranty and Disclaimer Limited Warranty ®

The Tech 8 Series of scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The Tech 8 Series scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all Tech 8 Series scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of Product or refund of Product price at the sole discretion of Metrologic. Faulty equipment must be returned to the Metrologic facility in Blackwood, New Jersey, U.S.A. or Puchheim, Germany. To do this, contact a Metrologic’s Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product which, in the sole judgement of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if the case of Product is opened by anyone other than Metrologic’s repair department or authorized repair centers. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC ALSO RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN.

Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683 Customer Service Department 1-800-ID-METRO (1-800-436-3876) TEL: 856-228-8100 FAX: 856-228-6673

Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b Munich, Germany TEL: 49-89-89019-0 FAX: 49-89-89019-200

11

Page 15

Appendix D Notices Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Any unauthorized changes or modifications to this equipment could void the users authority to operate this device. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice This Class A digital apparatus complies with Canadian ICES-003. Remarque Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard. Atención La modificación de los procedimientos, o la utilización de controles o ajustes distintos de los especificados aquí, pueden provocar una luz de láser peligrosa. Bajo ninguna circunstancia el usuario deberá realizar el mantenimiento del láser del escáner. Ni intentar mirar al haz del láser incluso cuando este no esté operativo. Tampoco deberá abrir el escáner para examinar el aparato. El hacerlo puede conllevar una exposición peligrosa a la luz de láser. El uso de instrumentos ópticos con el equipo láser puede incrementar el riesgo para la vista. Attention L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou le laser. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez à une rayonnement laser qú êst hazardous. L'emploi d'appareils optiques avec cet équipement laser augmente le risque d'endommagement de la vision. Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät hineinzusehen. Wenn Sie dies tun, können Sie sich einer gefährlichen Laserstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung. Attenzione L’utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale può provocare delle esposizioni a raggi laser rischiose. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa. L’uso di apparecchi ottici, equipaggiati con raggi laser, aumenta il rischio di danni alla vista.

12

Page 16

Appendix D (Continued) European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Funkstöreigenschaften nach EN 55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem fall kann vom Betrieber verlangt werden, angemessene Maßnahmen durchführen. Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure.

Attention Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la cause d’interférences radio. Dans ce cas l’utiliseteur peut être amené à predre les mesures adéquates.

13

Page 17

Appendix E Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No. 4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,607,156; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,923,281; 4,933,538; 4,960,985; 4,992,717; 5,015,833; 5,017,765; 5,059,779; 5,081,342; 5,117,098; 5,124,539; 5,130,520; 5,132,525; 5,140,144; 5,149,950; 5,180,904; 5,200,599; 5,216,232; 5,229,591; 5,247,162; 5,250,790; 5,250,791; 5,250,792; 5,262,628; 5,280,162; 5,280,164; 5,304,788; 5,321,246; 5,324,924; 5,396,053; 5,396,055; 5,408,081; 5,410,139; 5,436,440; 5,449,891; 5,468,949; 5,479,000; 5,532,469; 5,545,889; 5,557,093; 5,627,359; 5,637,852; 5,777,315; 5,789,731, No license right or sublicense is granted, either expressly or by implication, estoppel, or otherwise, under any METROLOGIC or third party intellectual property rights (whether or not such third party rights are licensed to METROLOGIC), including any third party patent listed above, except for an implied license only for the normal intended use of the specific equipment, circuits, and devices represented by or contained in the METROLOGIC products that are physically transferred to the user, and only to the extent of METROLOGIC’s license rights and subject to any conditions, covenants and restrictions therein.” Other worldwide patents pending.

14

Page 18

Index A AC outlet Application Application and protocols Asia ASIC Attaching stand A1 pin assignments A15 pin assignments

4 7 2 ii 1 5 9 10

B B units Bar codes Base Beeper operation Bracket

2 6 5 8 5

C Case 1, 5, 7 CDRH class IIa 2, 7 CDRH/IEC 7 CE Mark 7 Class 1 7 Clean 3, 8 Communication cable 1,4, 9, 10 Communication protocol 2 Compliance 4 Configuration 3 Connectors 4, 7, 9, 10 Connections 4 Construction 1 Containments 8 Contrast 8 Copyright ii Current 7 Customer Service ii, 11 D DC transformer Decode capability Depth of field Dimensions Disclaimer

7 8 6, 8 7 11

E Electrical Email EN 60825-1 Environmental

7 ii 2, 4 8

ESD EU Europe Exit angle

8 7 ii 8

F Faulty equipment Fax Functions

11 ii 9, 10

G Germany (GmbH) Good read Guides

11 8 1

H Headquarters Host Humidity ii 3, 4, 9, 10 8

I Input voltage Internet Introduction

7 ii 1

K Key

4

L Labels LASERKLASSE 1 LEDs Light levels Light pen emulation Light source Limited warranty Link cable Locations

2 2 5 8 2, 8 7 11 4 ii

M Maintenance MECCA Mechanical Mil spec connector Model number Mounting options

3, 8 1 7 4, 7, 9, 10 2 7

15

Page 19

Index N NEMA-12 steel case Notices

1, 7 12, 13

O OCIA Operating current Operating temperature Operational Optional interfaces Orientation

2, 9 7 8 8 8 7

P Patents Pin assignments Power consumption Print contrast Programming guide Protocols

15 9, 10 7 8 1 2

R RMA Roll, pitch, yaw RS-232

11 8 2, 8, 9

S Scan field Scanning bar codes Scan pattern Scanner connections ScanSet ScanSelect manual Scan speed Service

6, 8 6 8 4 3 1 8 1, 11

16

Shipping carton Socket-outlet South America Specifications Stand Storage temperature System interfaces T Temperature Top cover Transformer

1 4 ii 7, 8 1, 5, 7 8 8 8 7 4, 7, 9, 10

U UL/CSA 7 Units 2 USA corporate headquarters ii V Ventilation Version A1 Version A15 Version identifiers Vertical stand Visible laser diode Voltage W Warranty Weight Window