Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 2

TECH 8 Laser Bar Code Projection Scanner Installation and User's Guide, pages 1 to 10

Pages 1 to 10 of 19

The original document is the PDF (207 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic TECH 8 MS870

Page 1

®

METROLOGIC INSTRUMENTS, INC. ®

TECH 8 Laser Bar Code Projection Scanner Installation and User’s Guide

MLPN 2168 Printed in USA October 1999 Rev 01

Page 2

Locations USA Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Rd. Blackwood, NJ 08012-4683

Customer Service: 1-800-ID-METRO Telephone: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Internet: http://www.metrologic.com

South America Rua Flórida 1.821, 5° Andar- Brooklin CEP 04571-090, São Paulo-SP, Brasil

Outside Brazil Telephone: 55-11-5505-6568

Outside Brazil Metrologic South America

Fax: 55-11-5505-1681 Email: info@sa.metrologic.com In Brazil Telephone: 55-11-5505-2396

In Brazil Metrologic do Brasil Ltda

Fax: 55-11-5507-2301 Email: metrolog@br.metrologic.com

Europe Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany

Telephone: 49-89-89019-0 Fax: 49-89-89019-200 Email: metrologic@europe.metrologic.com

Asia Metrologic Asia (PTE) Ltd. 31, Kaki Bukit Road 3 #05-08 Techlink Singapore 417818

Telephone: 65-842-7155 Fax: 65-842-7166 Email: ahsu@sg.metrologic.com

Copyright © 1999 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.

ii

Page 3

Table of Contents Unpacking List................................................................................................................................ 1 Introduction .................................................................................................................................... 1 Labels............................................................................................................................................ 2 Applications and Protocols ........................................................................................................... 2 Maintenance.................................................................................................................................. 3 Configuration of the Scanner to the Host System ........................................................................ 3 Scanner Connections.................................................................................................................... 4 Attaching the Scanner to the Stand and Work Surface ............................................................... 5 Scanning Bar Codes ..................................................................................................................... 6 Appendix A Specifications ................................................................................................................. 7, 8 Appendix B Version A1 Pin Assignments for the Mil spec Connector................................................. 9 Version A15 Pin Assignments for the Mil spec Connector............................................. 10 Appendix C Warranty and Disclaimer ................................................................................................. 11 Appendix D Notices ...................................................................................................................... 12, 13 Appendix E Patents ............................................................................................................................ 14 Index...................................................................................................................................... 15, 16 iii

Page 4

Unpacking List The shipping carton, will contain the following: ®

•

TECH 8 Laser Bar Code Projection Scanner

•

Installation and User’s Guide

•

ScanSelect™ Scanner Programming Guide

•

Communication Cable (optional) or Communication Cable with Power Supply (optional)

•

Stand (optional)

If any item is missing or to order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.

Introduction Metrologic’s TECH 8® laser bar code projection scanner is encased in an NEMA-12 steel case. The scanner’s construction enables the scanner to operate in harsh surroundings, especially industrial environments. Water-resistant, shock-resistant, and rugged, the TECH 8 scanner is also fast, aggressive and reliable. It can register bar codes at a range of 203mm - 457mm (8" - 18") and can autodiscriminate among all common codes. Among the scanner’s many features is an ASIC (Application Specific Integrated Circuit) in the decoding system that virtually eliminates misreads and MECCA© (Metrologic Enhanced Code Correcting Algorithm). MECCA© enables the scanner to read poorly printed, wrinkled or even torn bar codes on the first pass. The scanner has been configured at the time of manufacture based on information supplied at the time of order.

1

Page 5

Labels The first label is found inside the window of the scanner noting that this device is a CDRH Class IIa laser product and EN 60825-1 LASERKLASSE 1. The second label is located on back of the scanner. This label contains information such as the model number, the date of manufacture and the serial number. The following are samples of the labels that are found on the unit.

Complies with 21 CFR Chapter 1 subchapter J. Class IIa laser Product. Avoid longterm viewing of direct laser light. LASERKLASSE 1

Metrologic®

Metrologic Instruments, Inc. Blackwood, New Jersey, USA Contains no user serviceable components. Warranty void if case is opened.

US

C LISTED 94J8 I.T.E.

This product complies with US DHHS Standard 21 CFR Chapter 1 Subchapter J. Class IIa Laser Product. Avoid long-term viewing of direct laser light. Eviter toute exposition prolongee de la vue au rayonnement laser direct. Apprareil laser Classe IIa

Complies with FCC and ICES-003 Class A. See manual. Manufactured Blackwood, NJ. 11-30V October 1999 Model : IS872-E1 TECH 8™ Barcode Scanner Serial # : XXXXXXXXXX

Patents #5,081,342; #1,268,257; #5,216,232 Worldwide Patents Pending

CAUTION: Laser light when opened. DO NOT STARE INTO BEAM.

Applications and Protocols The following chart lists the version identifiers for all the communication protocols. Listed on each scanner is a model number. The model number includes the scanner number, revision label, and denoted version identifier. For example, if the model number is MS870-B1, the scanner is an MS870, B is the revision level, and 1 is the version identifier.

B UNITS

2

Scanner

Version Identifier

Communication Protocol(s)

MS870

1

RS-232, OCIA

MS870

15

Light Pen Emulation

Page 6

Maintenance Smudges or dirt that appears on the scanner window can interfere with proper scanning. Therefore, the window will need occasional cleaning. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window.

Configuration of the Scanner to the Host System The scanner has been configured at the time of manufacture based on information supplied at the time of order. If ScanSet® is being used, refer to the ScanSet documentation for information on how to configure your scanner.

3

Page 7

Scanner Connections In order for the scanner to maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1. Turn off the host system. 2. Find the 19-pin female end of the scanner link cable and the widest key located above pins L and A. Align this key with the corresponding key on the scanner box’s Mil spec connector. While pushing in on the connector, rotate the ring clockwise until it locks into place with a click. 3. Connect the other end of the communication cable to the host device. The following statement is applicable if the optional power adapter available through Metrologic does not power the bar code scanner, and the scanner receives power from a host device such as a computer system.

Caution: To maintain compliance with standards CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source must meet applicable performance requirements for a limited power source. If the scanner will not receive power from a transformer, skip to Step 6. 4. If the scanner will receive power from an external power source, check the AC input requirements of the transformer to make sure the voltage matches the AC outlet. (A socket-outlet should be installed near the equipment and must be easily accessible.) 5. Plug the transformer into the AC outlet to supply power to the scanner. 6. Power up the host system. 7. Scan a few items to verify that data is being properly transmitted between the scanner and the host device.

4

Page 8

Attaching the Scanner to the Stand and Work Surface The scanner can be positioned in a vertical orientation with the Metrologic stand (Part #45478). To attach the unit to the stand and work surface purchase the following: four 6-32 x ½" (maximum length) machine screws and two (2) #10 pan head or two (2) #8 countersunk wood screws. (Refer to figure 1) 1. Lay the scanner face down on a clean cloth to prevent any scratches from occurring on the output window. Position the scanner so the red and green LEDs are pointed toward you. 2. Lay the stand on the scanner with the angled bracket pointing up and toward you. 3. Align the four clearance holes to the four holes in the scanner’s case. Fasten the scanner to the stand by inserting the four 6-32 x ½" screws into the four holes in the scanner’s case. 4. Drill two holes into the work surface that correspond with the holes in the 216mm - 96mm (8.5" x 3.80") base of the stand. 5. Use two pan head or countersunk wood screws to attach the scanner and stand to the work surface.

3

2

4&5

3.50 in. 5.00 in.

1.90 in.

1

Figure 1: Stand Installation

5

Page 9

Scanning Bar Codes The depth of field for the scanner is 203mm to 457mm (8" to 18") from the scanner window. The symbol must be passed through the scan area in order for the scanner to recognize the bar code. (Refer to Figure 2)

Figure 2

6

Page 10

Appendix A TECH 8® Laser Bar Code Scanner Specifications Application

Industrial Scanner

Light Source

Visible Laser Diode 670 ± 5nm

Laser Class

CDRH: Class IIa; EN 60825: Class 1

EMC

CE, UL listed for US and Canada

EMI

FCC, ICES-003 & EN 55022 Class A

Mechanical Dimensions

203mm x 216mm x 96mm (8"L x 8.5"W x 3.8"D)

Weight

3.5kg. (7.75 lbs.) without cable

Orientation

May be used in any orientation

Mounting

Vertical stand

Top Cover

NEMA-12 steel case

Cable Length

1.83m (6') cable with mil spec connector

Electrical Power

9 watts, host system or wall transformer

Input Voltage

11-30 VDC

Operating Current

450mA typical @ 20V

Standby Current

210mA typical @ 20V

DC Transformers

6061/6113-220V (AC in) 6062/6114-120V (AC in) 6115-240V (AC in) output 24/20VDC @ 750mA

Specifications subject to change without notice.

7