Page 9
GENERAL FEATURES AND CHARACTERISTICS THE LCD SCREEN The LCD screen of the OptimusR Portable Data Terminal displays program settings, operational parameters, data collected, and much more. The display is a graphical LCD with the following characteristics: Display area of 64 pixels x 100 pixels Resolution: y Maximum of 8 lines x 16 characters y Minimum of 4 lines x 12 characters y Displays alpha-characters, numbers, and symbols y Automated back light y y
THE LITHIUM BATTERY The OptimusR Portable Data Terminal includes a lithium-ion rechargeable battery pack. The battery is inserted (see Getting Started for battery installation) into the battery compartment of the Optimus and recharges with Optimus in the cradle and in charging mode.
Figure 4. Lithium-Ion Battery
MAINTENANCE Smudges and dirt on the unit's window can interfere with the unit's performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, non-abrasive cleaning cloth then gently wipe the window clean. If the unit's case requires cleaning, use a mild cleaning agent that does not contain strong oxidizing chemicals. Strong cleaning agents may discolor or damage the unit's exterior.
5
Page 10
GENERAL FEATURES AND CHARACTERISTICS LABELS The scanner and cradle have labels that provide important information including the model number, date of manufacture, serial number, safety and regulatory information. Figure 5 provides examples of these labels and their locations.
Figure 5. Label Sample and Location
6
Page 11
INSTALLATION GETTING STARTED The OptimusR Portable Data Terminal (PDT) requires minimal effort to begin functional operation for data collection in any application. In order to get started, the unit must have a fresh battery inserted into the battery compartment. 1. Access the battery compartment by removing the battery cover. To remove the cover, pull the cover release up on each side of the compartment and slide the cover away form the unit. 2. Insert the Li-ion battery into the battery compartment, battery information side up and battery contacts to the bottom, at an angle with the battery contacts inserted first. 3. Push the Li-ion battery the remainder of the way into the compartment. The battery will fit snuggly into place. 4. Close the battery compartment by sliding the battery cover toward the scan head until the cover locks into place. 5. Turn the unit over, so the keypad is visible and hold down the power button . 6. The LCD graphical display will display a menu and an audible indicator will sound to signify that the Optimus has been powered up properly. 7. Using the arrow keys select the Run Program option. 8. Scan a bar code. Note: The OptimusR comes with a default program loaded that allows users to scan items and enter their quantity. For information on how to create these programs, please refer to the Optimizer manual.
7
Page 12
INSTALLATION BASIC OPERATION In order for the Optimus to operate properly, an application program must be loaded onto the PDT. It is possible for the Optimus to power up without at active application. On power up if the Optimus has no application program loaded, then the following Program Manager menu options will appear on the display. MENU OPTIONS
Download
DESCRIPTION This option allows the user to download application programs (*.SHX), BASIC run-time (bas.ops.shx), BASIC programs (*.SYN) or font files to the terminal. There are six resident locations and one Active Memory. A maximum of seven programs can be downloaded to the terminal. The application program downloaded to the Active Memory will be the only activate program running. In order to activate one of the other programs, immediately after downloading, input a name for the program desired or just press the enter key to keep its current name if one is applicable. This will enable the user to download the program. The application file’s type, name, and size will be shown on the list of programs when entering the Download or Activate menu of the Program Manager. The file type is a small letter that follows the program number (01~06), it can be either ‘b’, ‘c’ or ‘f’ which represents BASIC program, C program or font file respectively. The program name is up to 12 characters and the program size is in units of K bytes. NOTE: In order to delete a program, select the program designated for deletion. From the program information screen, press the Alpha/Function key, then zero.
Activate
This option will enable the user to activate one of the resident programs. In order to accomplish this, the user must copy one of the six resident programs to the Active Memory. Upon activation of the new program, the original program in the Active Memory will be replaced. NOTE: A font file cannot be activated, and a BASIC program cannot be activated if the BASIC run-time does not exist.
Upload
The Upload option gives the user additional method for retrieving an application program. It allows a user to transmit the application programs to a host PC or another terminal. This function also allows a terminal to be cloned without going through a PC.
Selecting and successfully completing one of these three menu options will enable the OptimusR to begin functional operation.
8
Page 13
INSTALLATION COMMUNICATION AND DATA COLLECTION SETUP The OptimusR Series has various ways of communicating with a host device. Depending on the model of Optimus, it can communicate via RS232, USB, or Wi-Fi connection. The OptimusR can store data in the unit or send data real time via a Wi-Fi connection. The OptimusR has the ability to utilize a RS232 or USB connection to communicate to a host device for both application program downloads and data uploads. The OptimusR includes either a USB or RS232 cable. In order to begin an application download or data transfer the following steps would need to be followed. 1. Remove the Optimus cradle, the power supply, and either the USB or the RS232 cable from the box. 2. Plug the power supply into a power outlet and insert the other end into the cradle. The red LED on the cradle will illuminate if the power supply is connected correctly. 3. Follow steps a, b, or c a. For the RS232 cable, plug the 9 pin serial connector into a serial port on the host device. Plug the opposite end into the communication port of the cradle. b. For the USB cable, plug the USB end of the cable into an appropriate communication port on the host device and the opposite end of the cable into the communication port of the cradle*. c. For the Wi-Fi, connection to communicate with the host device the settings on OptimusR and the host device must be configured correctly. 4. Power up the Optimus and select the Utilities option. This will open additional menu options. 5. Select the Transfer Files option. 6. Select Get Program on the next menu. The unit is now ready to download an application program. 7. Place unit in cradle and download the appropriate application program. 8. Once the Optimus has received the application program, the unit is ready for scanning and collecting data. Note: There are OptimusR models available that do not include the cradle. Models that do not include a cradle as an accessory can have the power supply and the communication cable connected directly to the unit. * A software driver is required for proper installation. The driver is included with the installation CD provided with each Optimus. In addition, the driver can be downloaded from http://www.metrologic.com.
9
Page 14
INSTALLATION DATA UPLOAD 1. To transfer the data collected select the Utilities option. 2. Select the Download Method option on the next menu and then select the appropriate method for downloading files to the host device. 3. The Wi-Fi can send data in real time, however, if cradle options (Cradle-IR or IrDA) are selected re-insert the Optimus unit into the cradle and upload the data to the host device. To change the download method select the Utilities option from the main menu and then select the Download Method from the list of available options. This allows the user to alter the method by which data is transferred to the host device. Note: Plugging the Optimus into a serial port or USB port on the host device does not guarantee communication with the Optimus. Ensure that the communication port on the host device is not populated by another device. Confirm that the communication settings on both the host device and the Optimus correspond prior to a program download or data upload. The OptimusRW is similarly connected to the host device and programmed however, there is a key difference in the data collection process. The OptimusRW supports transmission of data wirelessly and as such has the capability of communicating that data in real time. The unit needs to be setup to communicate with the network as follows: 1. With the Optimus powered off, press and hold the 7, 9, and power keys. The System Module menu will appear on screen. 2. Using the arrow keys select the Wi-Fi Menu option. 3. The list of settings that appears is the settings that require configuration in order for the Wi-Fi to function effectively. 4. Select Information option to view the current configuration settings on the Optimus. 5. Select the Network Set option to configure the network settings. This is similar to enabling the network settings on a PC. 6. Select WLAN Setting to select and configure the Optimus for the appropriate network available to connect to the host device. 7. Select Security to setup any security/authentication settings that match the host device. 8. Select the Echo Test to test the settings and verify that the network settings on the Optimus are configured correctly and that the Optimus is communicating with the host device. 9. Power off the Optimus. Upon completion of the configuration process, and depending on the active application program, the user will be able to begin data transmission via Wi-Fi communication. Note: Contact a Metrologic Instruments representative if assistance is required when integrating a Metrologic device into a network.
10
Page 15
INSTALLATION THE SYSTEM MENU The system menu on the Optimus is another useful tool included with the Optimus. The system menu provides information about the Optimus and access to the system menu for configuring the Optimus. In order to access the system module, follow the instructions below: 1. With the Optimus powered off press down and hold the 7, 9, and power button. 2. An audible indicator will sound to indicate that the Optimus is powered on. 3. The Optimus will display the system menu.
System Menu Options • • • • • • • •
Information Settings Tests Memory Power Load Program Wi-Fi Menu Serial PPP Menu
INFORMATION The Information option provides information about the Optimus including: • • • •
Hardware Version Serial Number Manufacturing Date Application Program Version
Depending on the application program that is active on the Optimus, there are number of settings and options that may be selected for both setup and testing. The tables on page 12 show a number of those settings and their descriptions.
11
Page 16
INSTALLATION SETTINGS SETTING Clock Backlight ON Period CPU Speed Auto Off
Power On Options Key Click System Password Font Reset to Default
DESCRIPTION Set date and time for the system. Set the duration for the keyboard/LCD backlight Set CPU running speed. There are five speeds available: Full speed, half speed, quarter speed, eighth speed and sixteenth speed. Set time threshold for automatically power off when no operation is taking place during that specified period. If this value is set to zero, this function will be disabled. There are two possible selections: Program Resume, which starts from the program being used during the last session before the last power-off; and Program Restart, which starts with a new program. Select a tone for the beeper or disable the beeper when the user presses a key button. Set a password to protect the user from entering the system menu. Current font displayed on the Optimus display Resets the system settings to the default settings
DEFAULT N/A the light goes off after 20 seconds Full speed 10 minutes
Program Resume Enable no password is set System Font N/A
TESTS The OptimusR has numerous tests available to the user for both operation and diagnostics. Depending on the application program that is in the active memory will determine which tests can be performed and are available to the user. The following table provides a description of the available tests. SETTING
Reader
Buzzer LCD & LED Keyboard
Memory
DESCRIPTION To test the reading performance of the scanner. The following symbologies are enabled for the Reader test. All other symbologies will need to be enabled via programming. Default bar codes: Code 39, Industrial 25, Interleave 25, Codabar, Code 93, Code 128, UPCE, UPCE with ADDON 2, UPCE with ADDON 5, EAN8, EAN8 with ADDON 2 EAN8 with ADDON 5, EAN13, EAN13 with ADDON 2, and EAN13 with ADDON 5 To test the buzzer with different Frequency/Duration. Press ENTER key to start and then press any key to stop the test. To test LCD display and LED indicator. Press ENTER key to start and then press any key to stop the test. To test the rubber keys. Press a key and the result will be shown on the LCD display. Note that the FN key should be used in conjunction with numeral keys. To test the data memory (SRAM). Note after the test, the contents of the memory space will be wiped out. Warning: This test erases any data stored in the terminal.
Echo Test
12
Echo Test is used to test the communication between the cradle and the PC. Perform Echo test from the host device that the cradle is connected.