Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 4

SP5600 OptimusR User's Guide, pages 17 to 24

Pages 17 to 24 of 32

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic SP5600

Page 17

INSTALLATION MEMORY The menu option provides the user with the ability to gather information on the amount of memory available on the Optimus, as well as the ability to initialize the memory. This is accomplished by choosing one of the two available selections: 1. Size Info. 2. Initialize Size Info The Optimus contains three types of memory: Base RAM, SRAM and Flash memory. These three types of memory allow the Optimus to perform operational tasks at an optimal level. Base RAM: The Base RAM is the primary memory in the Optimus and is the location where application is stored and accessed. Memory Card: The Memory Card is basically SRAM and is memory that retains data as long as power is being supplied. SRAM does not have to be periodically refreshed and provides quick access to data. This is the location that the data collected will be stored. Flash memory: Flash memory is a type of constantly powered nonvolatile memory that can be erased and reprogrammed easily. This allows users to program the Optimus effortlessly. Initialize This selection enables the user of the Optimus to initialize the memory (SRAM). Warning: Initializing the memory will erase the current data in memory.

POWER Selecting the Power option allows the user to view the actual voltages of the main battery and the backup battery.

LOAD PROGRAM The selection of Load Program enables the user to download an application program to the Optimus. Note: For further information on application program downloads see the Optimizer User’s guide (MLPN 00-02052).

13

Page 18

INSTALLATION WI-FI MENU The Wi-Fi Menu will configure the OptimusR with the appropriate network and security settings for Wi-Fi communication. 1. 2. 3. 4. 5.

Information Network Set WLAN Setting Security Echo Test

Modifying TCP/IP settings can affect the performance of certain devices. Contact an IT professional to ensure that modifying these settings

Information The information setting lists the current network settings of the OptimusR. Network Set These are the network settings for the OptimusR. 1. SubNet Mask 2. IP Address 3. Gateway 4. DHCP 5. SSID 6. Server IP 7. Server Port 8. Echo Test WLAN Setting These are the Wireless Local Area Network settings. 1. Local Name 2. SSID 3. System Scale 4. Power Saving 5. Preamble 6. Ad-Hoc Security The security settings provide network authentication configuration settings to provide secure data transfer. 1. Authentications 2. WEP (Wired Equivalent Privacy) Menu 3. EAP (Extensible Authentication Protocol) Menu Echo Test Test to verify that the network settings are correct and communication from Optimus to host device is functioning.

14

Page 19

INSTALLATION APPLICATION The Application module runs on top of the System module. The OptimusR Series Portable Data Terminals are preloaded with the Optimizer’s run-time program and the following menu will be shown upon powering the unit up: 1. Run Program 2. Utilities* Utilizing the arrow keys select the menu option and execute it by pressing the ENTER key. For certain models of the OptimusR series the Data Optimizer program may need to be used in order to handle the in-coming and outgoing data to and from a host device. For detailed information, please refer to Optimizer User’s Guide (MLPN 0002052) and DataOptimizer User’s Guide. Note: If the Application Generator is used to create the application program, it will be necessary to download it to the terminal.

PROGRAMMING THE TERMINAL There are three software tools available for developing application programs for the terminal. • • •

The Optimizer Program Builder The ‘BASIC’ Compiler The ‘C’ Compiler

For detailed information, please consult the appropriate manual or contact Metrologic Instruments, Inc.

PROGRAMMING THE COMMUNICATION CRADLE The communication cradle of the OptimusR Portable Data Terminal supports serial IR interface only. If a customized PC application has been developed for communication with the terminal via the cradle, it will be necessary to first configure the cradle through programming. There is a DLL available for this purpose. For more information, please contact Metrologic Instruments, Inc. * To configure the wireless settings of the Optimus, see page 16 and the Wi-Fi menu options available in the system menu.

15

Page 20

TROUBLESHOOTING SYMPTOM

DESCRIPTION Make sure the battery is inserted and charged.

The scanner does not power up after pressing POWER key.

Charge the battery and check the charging status. If no charging information is shown on the display, reload the battery and check if the battery is properly installed then try again. Call for service if problem persists. Check if the cable is plugged tightly into host device and cradle.

The scanner cannot transmit data or programs to/from the terminal.

The keypad does not work properly.

Perform Echo test to confirm communication. Check if host communication parameters (COM port, baud rate, data bits, parity, and stop bit) match with the terminals. Verify that the communication port on the host device is not in use by another device. Turn off the power then enter the system menu. From the system menu, select Test and then its sub-item KBD. Perform the key-in test. Call for service if problem persists. Check if the bar codes used are enabled.

The scanner does not scan.

Check if battery-low indicator is shown on the LCD display. If yes, charge the battery. Call for service if problem persists. Open the battery cap and re-load the battery.

Abnormal responses.

Enter system menu. Run diagnostic test. Call for service if problem persists.

16

Page 21

SPECIFICATIONS OPTIMUSR SERIES OPERATIONAL Light Source: Normal Depth of Field: Width of Scan Field:

Visible Laser Diode (VLD) @ 650 nm 51 mm - 381 mm (2"-15")

0.33 mm (13 mil) bar code

305mm (12") @ 381 mm (15")

Single-Line Scan Speed: No. of Scan Lines: Min Bar Width: Decode Capability: Print Contrast: No. Characters Read: Beeper Operation: CPU: Program Memory: Data Memory: Display: Display Resolution: Communication (Unit):

42 scan lines per second 1 0.127 mm (5.0 mil) All standard 1-D bar codes including RSS-14, RSS-Expanded, and RSS-14 Limited 35% minimum reflectance difference Up to 80 data characters Maximum number will vary based on symbology and density. 7 tones or no beep 16-bit CMOS, low power consumption 2 MB Flash ROM 2 MB SRAM, expandable to 8 MB LCD 128 x 64 pixels, back-lit 8 lines x 20 Characters (max), 4 Lines x 15 characters (min) RS232, USB, IrDA, CradleIR or Wi-Fi

Communication (Cradle):

RS232 or USB

Application Development:

Windows-based Optmizer; optional C & BASIC compilers

17

Page 22

SPECIFICATIONS OPTIMUSR SERIES MECHANICAL Width (Unit):

81 mm (3.2")

Depth (Unit):

46 mm (1.8")

Height (Unit):

172 mm (6.77")

Weight (Unit):

10.6 oz (300 g) – including battery

Width (Cradle):

96 mm (3.8")

Depth (Cradle):

106 mm (4.17")

Height (Cradle):

80 mm (3.15")

ELECTRICAL Battery Operation: Battery Backup: Operation: Laser Class: EMC:

Li-ion 3.7V, 7.0mA hours, rechargeable lithium battery Over 200 hours, Over 16 hours (Wi-Fi) CDHR and IEC Class 2 in accordance with IEC 60825 – 1:1993 + A1:1997 + A2:2001 FCC Class B

ENVIRONMENTAL Operating Temperature:

0°C to 50°C (32°F to 122°F)

Storage Temperature:

-20°C to 60°C (-4°F to 140°F)

Humidity: Shock Resistance:

18

5% to 95% relative humidity, non-condensing 1.2 m (4') drop onto concrete

Page 23

LIMITED WARRANTY The OptimusR scanners are manufactured in Taipei, Taiwan. The OptimusR scanners have a one (1) year limited warranty from the date of manufacture. Metrologic warrants and represents that all OptimusR scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of product or refund of product price at the sole discretion of Metrologic. Faulty equipment must be returned to one of the following Metrologic repair facilities: Blackwood, New Jersey, USA; Madrid, Spain; or Suzhou, China. To do this, contact the appropriate Metrologic Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product which, in the sole judgment of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if: (i) the case of the Product is opened by anyone other than Metrologic's repair department or authorized repair centers; or (ii) any software is installed on the Product other than a software program approved by Metrologic. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN. CORPORATE HEADQUARTERS, NORTH AMERICA Metrologic Instruments, Inc. 90 Coles Rd. Blackwood, NJ 08012-4683 Customer Service Department Tel: 1-800-ID-METRO Fax: 856-228-6673 Email: info@metrologic.com

METROLOGIC EUROPEAN REPAIR CENTER (MERC) Metrologic Eria Ibérica, SL C/Alfonso Gomez, 38-40, 1D 28037 Madrid Tel: +34 913 751 249 Fax: +34 913 270 437

MTLG AUTO ID INSTRUMENTS (SHANGHAI) CO., LTD Suzhou Sales Office BLK A, Room# 03/03-04 No.5 Xinghan Street, Xinsu Industrial Square China-Singapore Suahou Industrial Park, Suzhou, PRC Tel: 86-512-67622550 Fax: 86-512-67622560 Email: info@cn.metrologic.com

19

Page 24

SAFETY NOTICES This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • • • •

Reposition or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the manufacturer for compliance could void the user's authority to operate this equipment.

20