The text of a manual · part 1 of 4
SP5600 OptimusR User's Guide, pages 1 to 8
Pages 1 to 8 of 32: SP5600 OptimusR User’s Guide; Manual Date Code
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic SP5600
Page 1
Metrologic
We really work for you.™
METROLOGIC INSTRUMENTS, INC.
SP5600 OptimusR User’s Guide ee
@Metrologic
Page 2
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc. or their respective
Page 3
TABLE OF CONTENTS Introduction Product Overview .................................................................................................................................................. 1 Scanner and Accessories ..................................................................................................................................... 1 General Features and Characteristics Scanner Features.................................................................................................................................................. 2 Cradle Features..................................................................................................................................................... 3 Multifunctional Keypad .......................................................................................................................................... 4 LCD Screen........................................................................................................................................................... 5 Lithium Battery ...................................................................................................................................................... 5 Maintenance.......................................................................................................................................................... 5 Labels.................................................................................................................................................................... 6 Installation Getting Started ...................................................................................................................................................... 7 Basic Operation..................................................................................................................................................... 8 Communication and Data Collection Setup .......................................................................................................... 9 Data Upload ........................................................................................................................................................ 10 System Menu ...................................................................................................................................................... 11 Application........................................................................................................................................................... 15 Programming the Terminal.................................................................................................................................. 15 Programming the Communication Cable ............................................................................................................ 15 Troubleshooting ....................................................................................................................................................... 16 Specifications........................................................................................................................................................... 17 Limited Warranty...................................................................................................................................................... 19 Safety Notices.......................................................................................................................................................... 20 Patents..................................................................................................................................................................... 21 Index ........................................................................................................................................................................ 22 Contact Information and Office Locations ............................................................................................................... 23 ii
Page 4
Page 5
INTRODUCTION PRODUCT OVERVIEW The SP5600 OptimusR Portable Data Terminals are robust and versatile scanning devices designed to provide exceptional performance, while enduring the demands of everyday use. The rugged exterior of the OptimusR makes the Optimus the ideal PDT for applications that take place in more rigorous environments. The lithium-ion rechargeable battery provides the Optimus with more than 200 hours of operation. The Optimus is supported by a resourceful set of development tools, including a Windows-based program builder, ‘C’ compiler, and ‘BASIC’ compiler. The OptimusR has a fully integrated laser for scanning all 1D bar code symbologies, completely enclosed by the protective ergonomic housing. The built-in functionality makes the Optimus an excellent choice for numerous applications. In addition, when combined with the optional Wi-Fi module the Optimus is the ideal solution for real time applications such as inventory control, shop floor management, warehousing operations, and distribution operations.
Key Product Features • • • • • • •
Up to 8 MB RAM capable of storing over 400,000 records Easy to use Optimizer program builder and download software Auto-backlit LCD display Audible and visual indications Built-in laser bar code scan engine capable of scanning all 1-D bar code symbologies Powered by rechargeable Lithium-ion battery Upload/download data via RS232, USB, and Wi-Fi interfaces
SCANNER AND ACCESSORIES METROLOGIC PART NUMBERS
PART DESCRIPTION
SP5602
OptimusR laser batch unit with 2MB RAM
SP5604
OptimusR laser batch unit with 4MB RAM
SP5608
OptimusR laser batch unit with 8MB RAM
SP5650
OptimusR laser Wi-Fi standard unit
SP5652
OptimusR laser Wi-Fi unit with 2MB RAM
SP5654
OptimusR laser Wi-Fi unit with 4MB RAM
SP5658
OptimusR laser Wi-Fi unit with 8MB RAM
MI5600-614
OptimusR standard cradle
MI5600-6107
OptimusR modem cradle
52-52860A
RS232 Cradle Cable
52-52861A
USB cradle cable
* For information on additional accessories and scanner kits, contact your local Metrologic Instruments representative.
1
Page 6
GENERAL FEATURES AND CHARACTERISTICS SCANNER FEATURES
Figure 1. Scanner Features
ITEM NO.
2
DESCRIPTION
1
Multi-functional Keypad
2
Scan Button
3
LCD display
4
Red Output Window (Laser Aperture)
5
Speaker for audible indicators
6
Protective rubber bumpers
7
Battery Compartment
8
Communication Ports (RS232 and IrDA), Power Adapter Port, and Battery Contacts
9
Comfort Strap
10
Battery Compartment Release
Page 7
GENERAL FEATURES AND CHARACTERISTICS CRADLE FEATURES
Figure 2. Cradle Features
ITEM NO.
DESCRIPTION
1
LED Transmission Indicator
2
LED Power indicator
3
Battery Contacts
4
IR communication port
5
Rubber Footpads
6
RS232 Communication Port and Power Adapter Port
3
Page 8
GENERAL FEATURES AND CHARACTERISTICS MULTIFUNCTIONAL KEYPAD
Figure 3. Keypad Features ITEM NO
4
KEY NAME
1
ALPHA()
2
ALPHANUMERIC
3
ARROW
4
ESC
5
SCAN
6
ENTER
7
BS
8
FUNCTION(FN)
9
POWER
DESCRIPTION The toggle key for Alphabet/Numeral input. When the system is in alpha-mode, a small icon will be shown in the lower right corner of the display. Each numeric key can be used to generate one of the three capital letters located on that number key. For example, number 2 can be used to produce A, B, or C. Pressing the same key twice within one second, will produce the letter B. Pressing the same key without halting longer than one second will allow the user to toggle through the three letters. When the key has been depressed for longer than one second or another key has been pressed, the unit will send the real key code to the application program. Alphanumeric. These 10 keys can be used for either alpha characters or numerical input. (See Item 8 for further description of key operation) Arrow. The four arrow keys located below the Scan key are used to toggle up and down between menu selections. Escape. This key is used to stop and exit current operation. Scan a bar code. Pressing this button will trigger the scanner to read a bar code. Enter. There are two enter keys on the side of the scan key. Normally the enter keys are used for command execution or input confirmation. Back Space. This key can be used to toggle back one space or if pressed down longer than one second, a clear code will be sent. The function key. This key cannot be activated alone; it must be pressed with one of the numeric keys at the same time. For example, FN + 1 generates function #1, FN + 2 generates function #2, etc (up to 9 functions). Also, this key can be combined with the UP/DOWN arrow keys to adjust the contrast of the LCD. And when this key is combined with the ENTER key, it will turn ON/OFF the backlight. Power On/Off. To prevent an accidental power down, it requires about 1.5 seconds of continuous pressing to turn On/Off the power.