Page 11
INSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE 1.
Follow the “Getting Started” steps on page 3.
2.
Turn off the host system.
3.
Disconnect the keyboard from the host.
4.
Connect the PowerLink cable to the jack labeled “Stand-Alone Keyboard” on the MS7220.
5.
Connect the other end of the PowerLink cable to the keyboard port on the host. Before continuing verify that the powerlink cable is connected to the proper communication jack on the scanner. Incorrect cable connection can cause communication problems or potential damage to the scanner.
6.
Connect the external power supply to the power jack on the PowerLink cable.
7.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.
8.
Connect AC power to the transformer. The outlet should be near the equipment and easily accessible.
9.
Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.
10. Turn on the host system.
Figure 3: Stand-Alone Keyboard Interface Load Keyboard Wedge Defaults
Scan 1St ³
9
9
9
9
9
4
Enable Stand-Alone Keyboard Wedge
11. Scan the two bar codes in order to Scan 2nd configure the MS7220 for Stand-Alone Keyboard communication.
³
5
1
5
5
1
5
3
Note: When scanning the bar codes, cover the code not being scanned to ensure the codes are read in the proper sequence. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
7
Page 12
INSTALLATION FOR USB INTERFACE 1.
Follow the “Getting Started” steps on page 3.
2.
Turn off the host system.
3.
Determine if your application requires USB Keyboard communication protocols or USB Point-of-Sale communication protocols.
4.
If you require USB Keyboard communication protocols, skip to step 5. If you require USB Point-of Sale communication protocols set the dip switches shown in figure 4a to positions 1 and 2.
5.
Connect the PowerLink cable to the nd 10-pin USB interface jack. It is the 2 round opening from the left side of the MS7220 (see figure 4b).
6.
Connect the other end of the USB cable to the host.
Figure 4a: POS Dip Switch
Before continuing verify that the USB cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner. Plugging the scanner into the USB port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication. 7.
Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.
Figure 4b: USB, Interface
8.
Turn on the host system.
Enable USB Defaults
9.
Scan the Enable USB Defaults bar code to configure the MS7220 for USB communication.
³
9
9
9
9
7
8
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
8
Page 13
INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES 1.
Follow the “Getting Started” steps on page 3.
2.
Turn off the host system.
3.
Connect the PowerLink cable to the 10-pin RS232/Light Pen interface jack. It st is the 1 round opening from the left side of the MS7220.
4.
Connect the other end of the PowerLink cable to the host. Before continuing verify that the powerlink cable is connected to the appropriate communication jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner.
5.
Connect the external power supply to the power jack on the PowerLink cable.
6.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.
7.
Connect AC power to the transformer. The outlet should be near the equipment and easily accessible.
8.
Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.
9.
Turn on the host system.
Figure 5: RS232 or Light Pen Interface
10. Scan the appropriate bar codes on page 10 to configure the MS7220 for RS-232 or Light Pen communication. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
9
Page 14
INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES Step 10, page 9 continued.
For RS232 Communication: Recall Defaults
Scan 1 st
³
9
9
9
9
9
8
Enable RS-232
Scan 2 nd
³
4
1
5
5
5
4
For Light Pen Communication: Recall Defaults
Scan 1 st
³
9
9
9
9
9
8
Enable Light Pen/Wand
Scan 2
10 nd
³
4
1
5
5
2
4
Page 15
INSTALLATION OF AN AUXILIARY SCANNER 1.
Turn off the host system.
2.
Connect the round end of the PowerLink RS232 AUX cable [ MLPN 54-54667A ] to the RS232 jack of the auxiliary scanner (see figure 6).
3.
Connect the other end of the PowerLink RS232 AUX cable into the 1 jack from the left side of the MS7320. The Aux jack has a square opening.
st
The following Metrologic scanners can be used in the “Aux” input of the MS7220: the MS9520, MS9540, MS6220, MS7120, MS6520, MS6720, MS7320 or another MS7220. Important: The MS7220 aux port requires the signals: transmit, receive, RTS & CTS from the auxiliary scanner. 4.
Connect the MS7220/Host PowerLink* cable to the appropriate interface jack on the back of the MS7220.
5.
Connect the other end of the MS7220/Host PowerLink cable to the Host.
6.
Connect the external power supplies for the auxiliary scanner and the MS7220 to the power jacks on the two PowerLink cables. Before continuing verify that the powerlink cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner.
7.
Check the AC input requirements of both power supplies to make sure the voltage matches the AC outlets.
8.
Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.
9.
Connect AC power to the transformers. The outlets should be near the equipment and easily accessible.
10. Configure the MS7220 for the appropriate interface configuration settings.* * The MS7220/host cable connection is interface dependent. Refer to the installation steps provided for the type of interface required for your application. Continued on page 12.
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
11
Page 16
INSTALLATION OF AN AUXILIARY SCANNER 11. Configure the auxiliary scanner to send formatted data to the MS7220. Normal slave mode operation will only require reserve Code 32 to be set in the auxiliary scanner. The Reserve Code 32 bar code applies for all scanners, except the MS6720, to be used as an auxiliary scanner. Contact a Metrologic representative for information on the MS6720.
Reserve Code 32
³
1
2
4
8
1
7
12. Configure the MS7220 to activate the auxiliary port. Enable the auxiliary port and configure it to recognize slave formatted data with the following bar code: Enable Aux Port
³
4
3
7
3
3
0
13. Turn on the host system.
Figure 6: Auxiliary Scanner Setup
12
Page 17
SCANNER PARTS n Output Window o Red LED p Green LED q Speaker r Side Cover s Cable Door t Cable Jack Cover u Horizontal Mount Base v Multi-Function Button (see page 15) Figure 7a: Scanner Parts w Cable Connection Area Foam Insert
Figure 7b: Scanner Parts
13
Page 18
POWER SAVE MODES AND THE MULTI-FUNCTION BUTTON The MS7220 has five programmable power save modes. Refer to the MetroSelect Programming Guide for additional information on Power Save Modes. 1.
Blink Power Save Mode (Default): “Blinks” the laser OFF & ON after a programmed period of non-use. When the scanner recognizes a bar code it will exit the Blink mode.
2.
Laser Off Power Save Mode: Turns the laser OFF after a programmed period of non-use. The motor continues to spin allowing for a faster “wake” up time. Pressing the Multi-Function button will “wake” the scanner from the Laser Off power save mode (see figure 8d).
3.
Laser & Motor Off Power Save Mode: Turns the laser and motor OFF after a programmed period of non-use. Pressing the Multi-Function button will “wake” the scanner from the power save mode (see figure 8d). This mode is the only power save mode that can be activated by the Multi-Function Button (see figure 8c). This mode’s “wake up” time is slightly longer due to the motor’s need to restart.
4.
Dual Action Power Save Mode #1: “Blinks” the laser OFF & ON after a programmed period of non-use turns the laser and motor OFF at thirty-minute intervals. Example: If the power save timeout is set to 15 minutes.
Last Scan
Laser starts “Blinking”
Laser & Motor turn OFF
Pressing the Multi-Function button will “wake” the scanner from the power save mode (see figure 8d). 5.
Dual Action Power Save Mode #2: Turns the laser OFF after a programmed period of non-use then turns the motor OFF after thirty-minute intervals. Example: If the power save timeout is set to 15 minutes.
Last Scan
Laser turns OFF
Motor turns OFF
Pressing the Multi-Function button will “wake” the scanner from the power save mode (see figure 8d).
14
Page 19
POWER SAVE MODES AND THE MULTI-FUNCTION BUTTON
Figure 8a: Multi-Function Button
CHANGING THE BEEPER TONE
Figure 8b: Changing the Beeper Tone
A Short (<3 second) depression and the beeper tone will change. The new tone will be heard, followed by a short pause. Then two more of the new tones will be heard signifying the new setting has been stored in memory. The silent (no beep) tone is also selectable.
PLACING THE UNIT IN LASER & MOTOR OFF POWER SAVE MODE
Figure 8c: Laser & Motor Power Save mode
Long (>3 seconds) depression The Laser & Motor Off Power Save Mode is the only power save mode that can be activated with the multi-function button.
WAKING THE UNIT FROM ALL POWER SAVE MODES The next button depression will awaken the scanner for normal operation. Figure 8d: Normal Operation
15
Page 20
AUDIBLE INDICATORS When the MS7220 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, use the Multi-Function Button or refer to the MetroSelect Programming Guide (MLPN 00-02407). One Beep When the scanner first receives power, the green LED will turn on, the red LED will flash and the scanner will beep once. The red LED will remain on for the duration of the beep. The scanner is now ready to scan. When the scanner successfully reads a bar code, the red LED will flash and the scanner beeps once (if programmed to do so). If the scanner does not beep once and the red light does not flash, then the bar code has not been successfully read. Razzberry Tone This is a failure indicator. Refer to failure modes page 17. Three Beeps - during operation When placing the scanner in program mode, the red LED will flash while the scanner simultaneously beeps three times. The red and green LEDs will continue to flash until the unit exits program mode. Upon exiting program mode, the scanner will beep three times and the red LED will stop flashing. When configured, 3 beeps can also indicate a communications timeout during normal scanning mode. When using one-code-programming, the scanner will beep three times (the current selected tone), followed by a short pause, a high tone and a low tone. This tells the user that the single configuration bar code has successfully configured the scanner. Three beeps will also occur during a manual adjustment of the beeper tone. With each short depression of the Multi-Function Button, the new tone will be heard, followed by a short pause then two more of the new current tones. Three Beeps - on power up This is a failure indicator. Refer to failure modes page 17.
16