The text of a manual · part 1 of 6

MS7220 ArgusScan Presentation Laser Scanner Installation and User's Guide, pages 1 to 10

Pages 1 to 10 of 56: MS7220 ArgusScan; Office Locations and Contact Information; Manual Date Code

The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MS7220

Page 1 read from a scan by OCR; it may hold reading errors

@ Metrologic’

METROLOGIC INSTRUMENTS, INC. MS7220 Argusscan’ Presentation Laser Scanner Installation and User's Guide gy'|

ACU UIILLIT

Page 2

Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.

Page 3

TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories..................................................................................... 2 Getting Started ..................................................................................................... 3 Installation OCIA Interface .................................................................................................. 5 Keyboard Wedge Interface ............................................................................... 6 Stand-Alone Keyboard Interface....................................................................... 7 USB Interface ................................................................................................... 8 RS232 or Light Pen Interfaces.......................................................................... 9 Auxiliary Scanner ............................................................................................ 11 Scanner Parts..................................................................................................... 13 Power Save Modes and The Multi-Function Button............................................ 14 Indicators Audible............................................................................................................ 16 Failure Modes ................................................................................................. 17 Visual.............................................................................................................. 18 Labels................................................................................................................. 19 Scan Volume ...................................................................................................... 20 Depth of Field by Minimum Bar Code Element Width......................................... 21 EAS Deactivation Antenna ................................................................................. 23 Maintenance....................................................................................................... 23 Troubleshooting Guide ....................................................................................... 24 RS232 Demonstration Program.......................................................................... 29 Applications and Protocols ................................................................................. 30 Design Specifications ......................................................................................... 31 Default Settings .................................................................................................. 33 MS7220 Stands Vertical Stand Parts [MLPN 46-46405 ] ............................................................ 39 Optional Flex Stand Parts [MLPN 46-46404 ] ................................................... 39 ii

Page 4

TABLE OF CONTENTS Vertical Stand Installation ............................................................................... 40 Optional Flex Stand Installation ...................................................................... 41 Scanner and Cable Terminations ....................................................................... 42 Limited Warranty ................................................................................................ 46 Laser and Product Safety ................................................................................... 47 Patents ............................................................................................................... 49 Index................................................................................................................... 50 Office Locations and Contact Information........................................................... 51 iii

Page 5

INTRODUCTION ®

ArgusScan is an aggressive, omnidirectional laser barcode scanner ideal for retail, convenience, liquor, and specialty store applications. Engineered with a large, easy-to-find optimal scan area, ArgusScan increases the first pass read rate for maximum productivity. ArgusScan is equipped with a multitude of standard features including: •

A bright 650 nm laser

•

Programmable depth of field

•

PowerLink user replaceable cables

•

MetroSet 2, MetroSelect and MetrOPOS compatible

•

Data editing (parsing) capability using Bits n' Pieces

•

A 2 year warranty

®

®

®

®

SCANNER

INTERFACE

MS7220-13

RS232, IBM 46xx, OCIA, Aux

MS7220-37

RS232, Light Pen, Keyboard Wedge, Stand-Alone Keyboard, USB, Aux

1

Page 6

SCANNER and Accessories BASIC KIT Part #

Description

MS7220

ArgusScan Presentation Scanner

00-02407

MetroSelect Programming Guide**

00-02554

MS7220 User’s and Installation Guide**

46-46406

Standard Horizontal Stand

46-46405

Standard Vertical Stand

®

**Also available for download at www.metrologic.com

OPTIONAL ACCESSORIES Part #

Description

AC to DC Power Transformer - Regulated 5.2V @ 1 A output 46-46759

120V United States

46-46616

220V – 240V Continental European

46-46615

220V – 240V United Kingdom

46-46984

220V – 240V China

46-46985

220V – 240V Australia

54-54xxx*

Straight PowerLink Cable with built in power jack. 2.1 m (7’) cord with short strain relief

53-53xxx*

Coiled PowerLink Cable with built in power jack. 2.7 m (9’) cord with long strain relief * xxx specifies connection to the host

54-54002

Keyboard Wedge PowerLink Cable w/ Adapter Cable

54-54020

Stand Alone Keyboard Wedge PowerLink Cable

54-54667

RS232 AUX PowerLink Cable

46-46404

Optional Flex Stand

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-IDMETRO or 1-800-436-3876.

2

Page 7

GETTING STARTED Tools needed: • Phillips head screwdriver • ¼”-20 wrench • Drill with a #39 drill bit (drill for hard-mount installation only) Slide off the cable cover.

Slide off the horizontal stand.

Slide on the cable door and remove the foam insert.

Loosen the lock nut, push back the metal base plate and then slide the cable through the cable opening.

Mounting the MS7220: Peel off the base plate’s tape backing and affix it to the countertop or drill four #39 pilot holes and secure the base plate to the countertop with the four #8 wood screws provided.

Continued on next page.

3

Page 8

GETTING STARTED Return the metal base plate to its original position then tighten the lock nut.

Return the foam insert to its original position then slide the horizontal stand back into place on the scanner.

Before continuing, determine what communication interface is needed then follow the installation procedure for that interface on pages 5-12.

It is important to use the correct communication jack on the back of the scanner (see pages 5-12 for cable the proper connections). Incorrect cable connections can cause communication problems or potential damage to the scanner

After the communication cable has been connected properly, slide the cable cover down then secure in place with the three M3x .5 x 6 mm pan head screws provided.

See the “MS7220 Stands” section of this guide for additional information on the vertical [ MLPN 46-46405 ] and flexible [ MLPN 46-46406 ] stand options.

4

Page 9

INSTALLATION FOR OCIA INTERFACE 1.

Follow the “Getting Started” steps on page 3.

2.

Turn off the host system.

3.

Connect the MVC cable to the 10-pin OCIA interface jack. It is the nd 2 round opening from the left side of the MS7220 (see figure 1).

4.

Connect the other end of the MVC cable to the host. Before continuing verify that the MVC cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration settings are also required for proper communication.

5.

Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.

6.

Turn on the host system.

7.

Scan the Load OCIA Defaults bar code to configure the MS7220 for OCIA communication.

Figure 1: OCIA, Interface

Load OCIA Defaults

³

9

9

9

9

9

3

For additional communication options for OCIA interfaces refer to the MetroSelect Programming Guide (MLPN 00-02407). Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 60950-00//UL 60950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

5

Page 10

INSTALLATION FOR KEYBOARD W EDGE INTERFACE 1.

Follow the “Getting Started” steps on page 3.

2.

Turn off the host system.

3.

Disconnect the keyboard from the host.

4.

Connect the PowerLink cable to the 10-pin nd KBW interface jack. It is the 2 round opening from the left side of the MS7220 (see figure 2).

5.

Connect the “Y” end of the PowerLink cable to the keyboard and the keyboard port on the host. If necessary use the male/female adapter cable supplied with the scanner for proper connections. Before continuing verify that the PowerLink cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner.

6.

Connect the external power supply to the power jack on the PowerLink cable.

7.

Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.

8.

Connect AC power to the transformer. The outlet should be near the equipment and easily accessible.

9.

Slide the cable cover into place on the back of the scanner then secure it with the three M3 screws provided.

Figure 2: Keyboard Wedge Interface Load Keyboard Wedge Defaults

10. Turn on the host system. 11. Scan the bar code below to configure the MS7220 for Keyboard Wedge communication.

³

9

9

9

9

9

4

Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 60950-00/UL 60950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

6