Page 21

FAILURE MODES Flashing Green and One Razzberry Tone This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair at an authorized service center.

Flashing Red and Green and Two Razzberry Tones This indicates the scanner has experienced a motor failure. Return the unit for repair at an authorized service center.

Continuous Razzberry Tone with both LEDs off If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an electronic failure. Return the unit for repair at an authorized service center.

Three Beeps - on power up If the scanner beeps 3 times on power up then, the nonvolatile memory that holds the scanner configuration has failed. Return the unit for repair at an authorized service center.

17

Page 22

VISUAL INDICATORS There is a red LED and a green LED on the front of the MS7220. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner. No Red or Green LED The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer.

Steady Green When the laser is active, the green LED is illuminated. The green LED will remain illuminated until the laser is deactivated. During the power save mode, the laser will turn on and off. During this period, the green LED remains illuminated.

Steady Green and Single Red Flash When the scanner successfully reads a bar code, the red LED will flash and the scanner will beep once. If the red LED does not flash or the scanner does not beep once, then the bar code has not been successfully read.

Steady Green and Steady Red After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s red LED will remain on until the data can be transmitted. Flashing Green then Flashing Red This indicates the scanner is in program mode. A razzberry tone indicates that an invalid bar code has been scanned in this mode. or If the unit is in sleep mode, each LED will flash once every 15 seconds.

Steady Red, Green off This indicates the scanner may be waiting for communication from the host.

18

Page 23

LABELS Each scanner has a label on the back of the unit. The label contains information such as the model number, date of manufacture, and the serial number. Additional CE and caution information has been molded into the back of the case. The following is an example of the back of the case with the label and molded text.

Figure 9: Back view of the case. (Top) Interface Label, Located Under the Cable Jack Cover (Bottom)

19

Page 24

SCAN VOLUME (DEFAULT) (BASED ON 100% UPC BAR CODES)

Figure 10: Top View Scan Volume (Default)

Figure 11: Side View Scan Volume (Default) Specifications subject to change without notice.

20

Page 25

DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT W IDTH (BASED ON 100% UPC BAR CODES)

Figure 12: Top View of Default Depth of Field

Minimum Bar Code Element Width mm mils

A .13 5.2

B .19 7.5

C .26 10.4

D .33 13

E .48 19

F .66 26

Specifications subject to change without notice.

21

Page 26

DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT W IDTH (BASED ON 100% UPC BAR CODES)

Figure 13: Side View of Default Depth of Field

Minimum Bar Code Element Width mm mils

A .13 5.2

B .19 7.5

C .26 10.4

Specifications subject to change without notice.

22

D .33 13

E .48 19

F .66 26

Page 27

EAS DEACTIVATION ANTENNA SW1 and SW2 are the switch banks inside the CheckPoint Device that set the deactivation range. Metrologic recommends end users program the MS7220 to the Fixed Low-Density depth of field, so that the unit does not scan out beyond the deactivation range. Unit #

CheckPoint Recommended Switch Bank Settings

MS7320

SW1 & SW2 switches 2, 3, 4, 5, and 6 set to ON

MS7220 Depth of Field Settings Default

*Note: Minimum element width changes to 6.8 mil when in this mode.

Figure 14: EAS Deactivation Antenna Contact Checkpoint Systems directly for additional EAS support.

MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. 2.

Spray glass cleaner onto lint free, non-abrasive cleaning cloth. Gently wipe the scanner window.

23

Page 28

TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms.

MS7220 Series Troubleshooting Guide SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

All Interfaces No LEDs, No beep or No motor spin

No power is being supplied to the scanner.

Check the transformer, outlet and power strip. Make sure the cable is plugged into the scanner.

No LEDs, No beep

No power is being supplied to the scanner from host.

Some host systems cannot supply enough current to power an ArgusScan. Use the power supply included with the scanner.

The unit beeps 3 times on power up.

There has been a Non-volatile RAM failure.

Contact a Metrologic service representative, if the unit will not hold the programmed configuration.

The unit razzes continuously on power up.

There is a RAM or ROM failure.

Contact a Metrologic service representative if the unit will not function.

At power up, there is a Razz tone and There has been a VLD failure. the green LED flashes.

Contact a Metrologic service representative.

At power up, there is a Razz tone and both LEDs flash.

Contact a Metrologic service representative.

There has been a scanner motor failure.

There are multiple The same symbol scans upon timeout is set too presentation of a short. bar code. The unit powers up, but does not beep.

24

The beeper is disabled. No volume is selected. No tone is selected.

Adjust the same symbol timeout for a longer time. Enable the beeper. Select a volume (programmable). Select a tone.

Page 29

TROUBLESHOOTING GUIDE (CONTINUED) SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

The unit is scanning a particular symbology that is not enabled.

UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been enabled.

The scanner has been programmed for a character length lock, or a minimum length and the bar code being scanned does not satisfy the programmed criteria.

Verify that the bar code being scanned falls into the programmed criteria. (Typical of Non-UPC/EAN codes. The scanner defaults to a minimum of 4 character bar code.)

The unit scans a bar code, but locks up after the first scan (the red LED stays on).

The scanner is configured to support some form of host handshaking but is not receiving the signal.

If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.

The unit scans, but the data transmitted to the host is incorrect.

The scanner’s data format does not match the host system requirements.

Verify that the scanner’s data format matches the host systems requirements. Make sure that the scanner is connected to the proper host port.

The unit powers up, but does not scan and/or beep.

The unit beeps for some bar codes and NOT for others of the same bar code symbology.

The print quality of the bar code is suspect. Check the character length lock. The aspect ratio of the bar code is out of tolerance.

Check the print mode. The type of printer could be the problem. Change print settings. For example change the print mode to econo or high speed.

25

Page 30

TROUBLESHOOTING GUIDE (CONTINUED) SYMPTOMS

The unit beeps for some bar codes and NOT for others of the same bar code symbology

POSSIBLE CAUSE(S)

SOLUTION

The bar code may have been printed incorrectly.

Check if it is a check digit/character/or border problem.

The scanner is not configured correctly for the type of bar code.

Check if the check digits are set properly.

The minimum symbol length setting does not work with the bar code.

Check if the correct minimum symbol length is set.

Keyboard Wedge Only The unit scans the bar code but there is no data.

The unit scans but the data is not correct.

The unit is transmitting each character

26

The configuration is not correct.

Make sure the scanner is configured for the appropriate mode.

The configuration is not correct.

Make sure that the proper PC type (AT, PS2 or XT) is selected. Verify the correct country code and data formats are selected. Adjust the intercharacter delay.

The configuration is not correct.

Increase the interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.