The text of a manual · part 3 of 17
ScanSelect Scanner Programming Guide, pages 21 to 30
Pages 21 to 30 of 164
The original document is the PDF (376 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS6720
Page 21
Minimum Symbol Length (Byte)
0
12345
90700
5
To specify the minimum number of characters in the bar codes that will be scanned, scan the above bar code and the appropriate Code Byte bar code in Section I.
Symbol Length Lock (Byte)
0
12345
90800
2
When the scanner will always scan bar codes that are the same length, the length of the bar code can be locked into place by scanning the above bar code and the appropriate Code Byte bar code in Section I. A - 13
Page 22
Section B Communication Protocol This section provides bar codes that can be enabled or disabled for the proper communication interface for a specific host device.
Enable RS-232 Enable IBM 4680 Communication Enable Parallel Communication Enable Light Pen Emulation Enable No Communication Mode OCIA Output Multi-drop Network Enable Keyboard Wedge Emulation
(B - 1) (B - 1) (B - 1) (B - 1) (B - 2) (B - 2) (B - 2) (B - 4)
RS-232 Protocols Parallel Protocols Light Pen Protocols OCIA Protocols Poll Light Pen Source *Do Not Poll Light Pen Source E/D Light Pen Extra Transition Multi-drop Address
B-i
(B - 3) (B - 3) (B - 3) (B - 3) (B - 4) (B - 4) (B - 5) (B - 5)
Page 23
*Enable RS-232
0
12345
Enable Parallel Communication
30955
7
0
When this option is enabled, the scanner will work with RS-232 +-12V serial output.
12345 30915 1 This option should be selected if the scanner will provide parallel output to various cash registers. This is not Centronics parallel and should not be connected to such an interface. For the most part, parallel registers allow input of UPC/EAN bar codes only.
Enable IBM 4680 Communication Enable Light Pen Emulation
12345 30905 0 2 This option should be selected if communications with an IBM 46XX register is needed. This will enable RS-485 communications. Not all scanners support this interface as the correct interface board is required.
0
12345
30925
0
This option should be selected if the scanner will be used in place of a light pen. It will provide light pen emulation of each bar code that is scanned.
B-1
Page 24
Enable No Communication Mode
0
12345
30935
Multi-drop Network
0
9
This option should be selected if the scanner will not interface with a host device.
12345
30965
6
This option should be selected if the scanner will provide RS-422 type output for National Semi-conductor/ICL cash registers. This is a specific format which is only supported when the proper interface board is being used.
OCIA Output Enable Keyboard Wedge Emulation
12345 30945 0 8 This option should be selected if the communications requirement is OCIA (Optically Coupled Interface Adaptor). This is a clocked (by the host) serial interface.
0
B-2
12345 30975 5 This option should be selected if the scanner will provide keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent.
Page 25
0
12345
20903
0
1
-
RS-232 Parallel Light Pen OCIA
Odd Parity IBM Spaces High as Code 39 DTS/SIEMENS
0 0
12345
20913
= = =
9
= = = =
12345
Even Parity Fujitsu Spaces High/ as Scanned NCR F
20933
8
When using one of the following communications, this feature will work as indicated:
0
When using one of the following communications, this feature will work as indicated: RS-232 Parallel Light Pen OCIA
20923
When using one of the following, this feature will work as indicated:
When using one of the following, this feature will work as indicated: RS-232 Parallel Light Pen OCIA
12345
RS-232 Parallel Light Pen OCIA
*Space Parity *SWEDA *Bars High as Code 39 *DTS/NIXDORF
B-3
= = = =
Mark Parity OMRON Bars High/ as Scanned NCR S
Page 26
Enable Light Pen Extra Transition Before Bar Cod
Poll Light Pen Source
12345
12515
0
12345
12812
When this option is chosen, the scanner will wait for an active source voltage before transmitting the data.
7 When this option is enabled, the scanner will toggle the light pen data line prior to transmitting the bar code. This may be needed for certain decode devices.
*Do Not Poll Light Pen Source
*Disable Light Pen Extra Transition Before BarCod
0
7
0
12345 12505 0 8 When this option is chosen, the scanner will not wait for an active source voltage before transmitting the data.
12345
12802
8
When this option is disabled, the scanner will not toggle the light pen data line prior to transmitting the bar code. B-4
Page 27
Multi-drop Address
0
12345
93100
0
When using Multi-drop communication, scan the above bar code and the appropriate Code Byte in Section I to specify the address.
Enable Keyboard Wedge Emulation
0
12345
30975
5
This option should be selected if the scanner will provide keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent. B-5
Page 28
Section C Scanner Operation This section provides bar codes that can change the general operating characteristics of the scanner. These include beeper operation, timeout options, depth of field, and test modes. E/D = Enable/Disable Normal Tone Alternate Tone 1 Alternate Tone 2 No Beep E/D Fast Beep Loudest Volume Setting Medium Volume Setting Lowest Volume Setting Quietest (No Volume) Beep Before/After Transmit E/D Communication Time-outs Razz Tone on Time-out No Razz Tone on Time-out Three Beeps on Time-out No Beeps on Time-out 10 Min Touchplate/IR Time-out 2 Min Touchplate/IR Time-out 30 Min Touchplate/IR Time-out No Touchplate/IR Time-out
(C - 1) (C - 1) (C - 1) (C - 1) (C - 2) (C - 2) (C - 2) (C - 3) (C - 3) (C - 3) (C - 4) (C - 4) (C - 4) (C - 5) (C - 5) (C - 5) (C - 5) (C - 6) (C - 6)
E/D No Same Symbol Time-out E/D Infinite Same Symbol Time-out E/D Same Symbol Rescan Time-out: 100 msec Same Symbol Rescan Time-out: 200 msec Same Symbol Rescan Time-out: 500 msec Same Symbol Rescan Time-out: 1250 msec Same Symbol Rescan Time-out: 2000 msec Scanability On/Off Scan Count Mode On/Off Extended Depth of Field Normal Depth of Field Close Depth of Field Intercharacter Delay: RS-232 Protocols Parallel Protocols OCIA Protocols KB Wedge Protocols 1 Scan Buffer 2 Scan Buffers
C-i
(C - 6) (C - 7) (C - 7) (C - 8) (C - 8) (C - 8) (C - 8) (C - 9) (C - 9) (C - 10) (C - 10) (C - 10) (C - 11, C - 12) (C - 11, C - 12) (C - 11, C - 12) (C - 11, C - 12) (C - 13) (C - 13)
Page 29
*Normal Tone
Alternate Tone 2
12345 21036 0 5 The following beeper tone options are available: Normal, Alt 1, Alt 2, and No Beep. When No Beep is chosen, the scanner will not emit an audible beep.
0
Alternate Tone 1
0
12345
12345 21016 7 The following beeper tone options are available: Normal, Alt 1, Alt 2, and No Beep. When No Beep is chosen, the scanner will not emit an audible beep.
No Beep
21026
6
0
The following beeper tone options are available: Normal, Alt 1, Alt 2, and No Beep. When No Beep is chosen, the scanner will not emit an audible beep.
C-1
12345
21006
8 The following beeper tone options are available: Normal, Alt 1, Alt 2, and No Beep. When No Beep is chosen, the scanner will not emit an audible beep.
Page 30
Enable Fast Beep
*Loudest Volume Setting
12345 12810 3 When this option is selected, the scanner will use the selected tone but shorten the duration of the beep.
0
0
12345
21034
1
The following beeper volume options are available: Quietest (No Volume), Lowest, Medium, and Loudest. When Quietest is chosen, the scanner will not emit an audible beep.
Medium Volume Setting *Disable Fast Beep
0
12345 12800 0 4 When this option is selected, the scanner will not shorten the beep duration.
12345
21024
2
The following beeper volume options are available: Quietest (No Volume), Lowest, Medium, and Loudest. When Quietest is chosen, the scanner will not emit an audible beep.
C-2