Page 11

*Enable Interleaved 2 of 5 (ITF)

Enable MOD 10 Check on ITF

12345 10105 2 When this option is enabled, the scanner will scan Interleaved 2 of 5 (ITF) bar codes.

0

0

12345 10210 3 When this option is enabled, the scanner will scan Interleaved 2 of 5 (ITF) bar codes that have a Modulo 10 check digit.

*Disable MOD 10 Check on ITF Disable Interleaved 2 of 5 (ITF)

0

12345

10115

0 1

When this option is disabled, the scanner will not scan Interleaved 2 of 5 (ITF) bar codes. A-3

12345 10200 4 When this option is disabled, the scanner will not scan ITF bar codes that have a Modulo 10 check digit.

Page 12

Enable Code 11

0

12345

*Enable Code 39

10203

5

0

12345

10101

4

When this option is enabled, the scanner will scan Code 11 bar codes.

When this option is enabled, the scanner will scan Code 39 bar codes.

*Disable Code 11

Disable Code 39

0

12345

10213

4

0

When this option is disabled, the scanner will not scan Code 11 bar codes.

12345

10111

3

When this option is disabled, the scanner will not scan Code 39 bar codes. A-4

Page 13

Enable Full ASCII Code 39

0

12345

10217

Enable MOD 43 Check on Code 39

2

0

When this option is enabled, the scanner will scan Full ASCII Code 39 bar codes.

12345 10211 0 When this option is enabled, the scanner will scan Code 39 bar codes that have a Modulo 43 check digit.

*Disable MOD 43 Check on Code 39

*Disable Full ASCII Code 39

0

12345 10207 0 3 When this option is disabled, the scanner will not scan Full ASCII Code 39 bar codes. A-5

12345 10201 1 When this option is disabled, the scanner will not scan Code 39 bar codes that have a Modulo 43 check digit.

Page 14

Enable MSI Plessey

0

12345

10202

Enable MSI Plessey 10/10 Check Digits

8

0

12345

20334

3

When this option is enabled, the scanner will scan MSI Plessey bar codes.

When this option is enabled, the scanner will scan MSI Plessey bar codes that have a double Modulo 10 check digit.

*Disable MSI Plessey

*Enable MSI Plessey MOD 10 Check Digits

0

12345

10212

7

0

When this option is disabled, the scanner will not scan MSI Plessey bar codes.

A-6

12345 20324 4 When this option is enabled, the scanner will scan MSI Plessey bar codes that have a single Modulo 10 check digit.

Page 15

Disable Both MSI Plessey Check Digits

0

12345

20304

Enable UK Plessey

6

0

When this option is chosen, the scanner will not scan MSI Plessey bar codes that have a single or double Modulo 10 check digit.

12345

12814

1

When this option is enabled, the scanner will scan UK Plessey bar codes.

*Disable UK Plessey

0

A-7

12345

12804

2 When this option is disabled, the scanner will not scan UK Plessey bar codes.

Page 16

Enable Airline 2 of 5

0

12345

12911

Enable Telepen

7

0

When this option is enabled, the scanner will scan Airline 2 of 5 bar codes.

12345

12901

12916

2

When this option is enabled, the scanner will scan Telepen bar codes.

*Disable Telepen

*Disable Airline 2 of 5

0

12345

0

8

12345

12906

3

When this option is disabled, the scanner will not scan Telepen bar codes.

When this option is disabled, the scanner will not scan Airline 2 of 5 bar codes. A-8

Page 17

Enable MECCA

Enable Paraf Support

12345 10100 0 7 When this option is enabled Metrologic Enhanced Code Correcting Algorithm (MECCA) will be activated. This feature allows for increased accuracy in reading poor quality bar codes, but may slightly. reduce the aggressiveness of the scanner.

0

12345

10205

9

When this option is enabled, the scanner will convert Code 39 bar codes to paraf format.

*Disable Paraf Support

*Disable MECCA

0

12345

10110

0

6

12345

10215

8

When this option is disabled, the scanner will not convert Code 39 bar codes to paraf format.

When this option is chosen, MECCA will not be active. A-9

Page 18

Enable Matrix 2 of 5

0

12345

12912

*Enable EAN-8

4

0

When this option is enabled, the scanner will scan Matrix 2 of 5 bar codes

*Disable Matrix 2 of 5

0

12345

12902

12345 10214 1 When this option is enabled, the scanner will scan EAN-8 bar codes.

Disable EAN-8

5

0

When this option is disabled, the scanner will not scan Matrix 2 of 5 bar codes.

12345

10204

2

When this option is chosen, the scanner will not scan EAN-8 bar codes. A - 10

Page 19

*Enable EAN-13

*Enable UPC-E

12345 10317 0 9 When this option is enabled, the scanner will scan EAN-13 bar codes.

0

12345 10316 2 When this option is enabled, the scanner will scan UPC-E bar codes.

Disable UPC-E

Disable EAN-13

12345 10307 0 0 When this option is chosen, the scanner will not scan EAN-13 bar codes.

0

12345

10306

3

When this option is chosen, the scanner will not scan UPC-E bar codes. A - 11

Page 20

*Enable UPC-A

ITF Symbol Length 1 (Byte 1)

12345 10216 0 5 When this options enabled, the scanner will scan UPC-A bar codes.

0

12345

90500

1

To specify the number of ITF (Interleaved 2 of 5 digits in the bar codes that will be scanned, scan the above bar code and the appropriate Code Byte bar code in Section I.

ITF Symbol Length 2 (Byte 2)

Disable UPC-A

0

12345

10206

0

6

12345

90600

8

To specify a second number, scan the above bar code and the appropriate Code Byte bar code in Section I. Only scan the above bar code when a second ITF number needs to be specified.

When this option is chosen, the scanner will not scan UPC-A bar codes.

A - 12