The text of a manual · part 1 of 17
ScanSelect Scanner Programming Guide, pages 1 to 10
Pages 1 to 10 of 164
The original document is the PDF (376 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS6720
Page 1
ScanSelect™ Scanner Programming Guide
MLPN 2186
Page 2
Locations: USA Corporate Headquarters Metrologic Instruments, Inc. Blackwood, NJ 08012 Customer Service: 1-800-ID-METRO Tel: 609-228-8100 Fax: 609-228-6673 South America Metrologic Instruments CEP 04571-090, São Paulo-SP, Brasil Outside Brazil: Tel: 55-11-5505-6568 Fax: 55-11-5505-1681 In Brazil: Tel: 55-11-5505-2396 Fax: 55-11-5507-2301
Europe Metrologic Instruments GmbH Munich, Germany Tel: 49-89-89018-0 Fax: 49-89-89019-200 ASIA Metrologic Asia (PTE) Ltd. Singapore 417818 Tel: 65-842-7155 Fax: 65-842-7166
Copyright © 1998 by Metrologic® Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.
ii
Page 3
Enter/Exit Program Mode
0
12345
66666 iii
7
Page 4
Load Defaults
0
12345
66661 iv
2
Page 5
Introduction Section A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code Types Section B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Communication Protocol Section C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Scanner Operation Section D. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Format Options Section E. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-232 Parameters Section F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Keyboard Wedge Parameters Section G. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Reserved Features Section H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Supplemental/UCC Codes Section I. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code Bytes Section J. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6720 Specific Codes v
Page 6
Introduction
Load Defaults
The scanner is shipped from the factory programmed to a set of default conditions noted in this guide by an asterisk that appears before the brief definition. Since each host system is unique, configure the scanner to match the specific host system requirements. 1.
Connect the scanner to the host system. (Refer to the Installation and User’s Guide)
2.
Enter the program mode by scanning the ENTER/EXIT program mode bar code.
3.
Scan the appropriate the bar code(s) that appear in this guide. (Reveal only one bar code to the scanner each time.)
4.
Exit the program mode by scanning the ENTER/EXIT bar code again.
0
12345
66661
2
If the original factory settings are needed during the programming of the scanner, scan the LOAD DEFAULTS bar code. Any settings selected during that session or any previous session will be lost. This will return the scanner to the RS-232 communication protocol. For other communications activate the protocol, i.e., OCIA, Keyboard Wedge, IBM. Then change all necessary parameters for the protocol. Verify that the scanner hardware is equipped/configured for the appropriate interface.
Enter/Exit Program Mode
Note: The default settings for the non-RS232 protocols are different when enabled via ScanSelect™ versus ScanSet™.
0
12345
66666
7 vi
Page 7
Cloning allows the configuration of a scanner by making its settings the same as another scanner. This is done by connecting the cloning cable between the two scanners. 1.
Turn off both scanners.
2.
Connect the cloning cable between the two scanners.
3.
Turn both the scanners on by plugging in the transformers.
4.
Once each scanner is ready, scan the cloning bar code with the scanner that has the settings that need to be transferred to the other scanner.
Configuration
0
12345
77777
66669
8
While in the Program Mode, scan the Configuration bar code to allow the scanner to transmit the current scanner configuration to an RS232 host. The scanner will transmit a sequential list of bar code data that can be printed as UPC bar codes and used to configure another scanner to match the first scanner.
Cloning
0
12345
6 vii
Page 8
Section A Code Types This section provides various bar codes that can be enabled or disabled that are needed for a specific application. E/D = Enable/Disable
E/D UPC/EAN (A - 1) E/D Code 128 (A - 1) E/D Code 93 (A - 2) E/D Codabar (A - 2) E/D ITF (A - 3) E/D Mod 10 Check on ITF (A - 3) E/D Code 11 (A - 4) E/D Code 39 (A - 4) E/D Full ASCII Code 39 (A - 5) E/D Mod 43 Check Code 39 (A - 5)
CD = Check Digit
E/D MSI Plessey E MSI Plessey 10/10 CD E MSI Plessey Mod 10 CD D Both MSI Plessey CD E/D UK Plessey E/D Airline 2 of 5 E/D Telepen E/D MECCA E/D Paraf Support E/D Matrix 2 of 5
(A - 6) (A - 6) (A - 6) (A - 7) (A - 7) (A - 8) (A - 8) (A - 9) (A - 9) (A - 10)
A-i
E/D EAN-8 E/D EAN-13 E/D UPC-E E/D UPC-A ITF Symbol Length 1 (Byte 1) ITF Symbol Length 2 (Byte 2) Minimum Symbol Length (Byte) Symbol Length Lock (Byte)
(A - 10) (A - 11) (A - 11) (A - 12) (A - 12) (A - 12) (A - 13) (A - 13)
Page 9
*Enable UPC/EAN
12345
*Enable Code 128
10106
When this option is enabled, the scanner will scan UPC/EAN bar codes.
12345 10103 8 When this option is enabled, the scanner will scan Code 128 bar codes.
Disable UPC/EAN
Disable Code 128
0
0
12345
10116
9
0
8
0
When this option is disabled, the scanner will not scan UPC/EAN bar codes.
12345
10113
7
When this option is disabled, the scanner will not scan Code 128 bar codes.
A-1
Page 10
*Enable Code 93
0
12345
*Enable Codabar
10102
1
0
When this option is enabled, the scanner will scan Code 93 bar codes.
12345 10104 5 When this option is enabled, the scanner will scan Codabar bar codes.
Disable Codabar Disable Code 93
0 0
12345
10112
0
12345
10114
4
When this option is disabled, the scanner will not scan Codabar bar codes.
When this option is disabled, the scanner will not scan Code 93 bar codes. A-2