Page 31
Lowest Volume Setting
0
12345
21014
*Beep Before Transmit
0
3
12345
11013
9
The following beeper volume options are available: Quietest (No Volume), Lowest, Medium, and Loudest. When Quietest is chosen, the scanner will not emit an audible beep.
When this option is chosen, the scanner will beep before each label is transmitted.
Quietest (No Volume)
Beep After Transmit
0
12345
21004
0
4
12345
11003
0
When this option is chosen, the scanner will beep after each label is transmitted.
The following beeper volume options are available: Quietest (No Volume), Lowest, Medium, and Loudest. When Quietest is chosen, the scanner will not emit an audible beep. C-3
Page 32
Enable Communication Time-outs
0
12345
11012
Razzberry Tone on Time-out
2
0
When this option is enabled, the scanner will time-out if it does not transmit its data to the host after two seconds during communication. This is only valid in modes where some type of handshaking is involved.
12345 11011 5 When this option is chosen, the scanner will produce an audible razzberry tone when communications have timed out.
*Disable Communication Time-outs No Razzberry Tone on Time-out
0
12345
11002
3 0
When this option is disabled, the scanner will not time-out if it does not transmit its data to the host after two seconds during communication. This is only valid in modes where some type of handshaking is involved. C-4
12345 11001 6 When this option is chosen, the scanner will not produce an audible razzberry tone when communications have timed out.
Page 33
Three Beeps on Time-out
0
12345
11010
*10 Minutes Touchplate/IR Time-outs
12345 20930 7 This time represents the duration of time of inactivity from the last scan until the scanner enters a “standby” mode. The scanner will not return to scanning until either the scanner’s touchplate is pressed or an object is waved in front of the IR sensor.
8
0
When this option is chosen, the scanner will beep three times when communications have timed out.
Two Minutes Touchplate/IR Time-outs
No Beeps on Time-out
0
12345
11000
0
9
12345
20920
8
This time represents the duration of time of inactivity from the last scan until the scanner enters a “standby” mode. The scanner will not return to scanning until either the scanner’s touchplate is pressed or an object is waved in front of the IR sensor.
When this option is chosen, the scanner will not beep when communications have timed out.
C-5
Page 34
Thirty Minutes Touchplate/IR Time-outs
0
12345
20910
Enable No Same Symbol Time-out
9
0
This time represents the duration of time of inactivity from the last scan until the scanner enters a “standby” mode. The scanner will not return to scanning until either the scanner’s touchplate is pressed or an object is waved in front of the IR sensor.
12345 12815 8 When this option is enabled, the same bar code is scanned again without any time delay. When enabled, this option overrides any selected same symbol rescan time-out option.
No Touchplate/IR Time-outs
0
12345
20900
*Disable No Same Symbol Time-out
0
0
When this option is chosen, the scanner will not enter a “standby” mode. When using a Tech scanner, select this option since these units do not have an IR sensor or a touchplate.
12345
12805
9
When this option is disabled, there is a same symbol rescan time-out.
C-6
Page 35
Enable Infinite Same Symbol Time-out
0
12345
12816
Enable Same Symbol Rescan Time-out: 10 msec
5 0
When this option is enabled, the scanner never scans the same bar code repetitively during a scanning session. When enabled, this option overrides all of the same symbol rescan time-outs.
12345
12811
0
The available same symbol time-outs are 100, 200, 500, 1250 and 2000 milliseconds. These numbers represent the amount of time that a bar code must be out of the scan field before that bar code can be scanned again. *Disable Same Symbol Rescan Time-out: 100 msec
*Disable Infinite Same Symbol Time-out
12345 12806 0 6 When this option is disabled, the same bar code can be scanned again after a rescan time-out.
0
12345
12801
1
When this option is disabled, any other selected same symbol rescan time-out will be recognized. Note: If 100 mesc is enabled, the time-out will override all other rescan time-outs until the above bar code is scanned.
C-7
Page 36
Same Symbol Rescan Time-out 200 msecs
0
12345
21130
Same Symbol Rescan Time-out: 1250 msec
0
0
12345
21110
2
The available same symbol time-outs are 200, 500, 1250 and 2000 milliseconds. These numbers represent the amount of time that a bar code must be out of the scan field before that bar code can be scanned again.
The available same symbol time-outs are 200, 500, 1250 and 2000 milliseconds. These numbers represent the amount of time that a bar code must be out of the scan field before that bar code can be scanned again.
*Same Symbol Rescan Time-out: 500 msecs
Same Symbol Rescan Time-out 2000 msec
0
12345
21120
1
0
The available same symbol time-outs are 200, 500, 1250 and 2000 milliseconds. These numbers represent the amount of time that a bar code must be out of the scan field before that bar code can be scanned again.
12345
21100
3
The available same symbol time-outs are 200, 500, 1250 and 2000 milliseconds. These numbers represent the amount of time that a bar code must be out of the scan field before that bar code can be scanned again. C-8
Page 37
Scanability On
Scan Count Mode On
12345 11117 4 When this option is enabled, the scanner will enter scanability test mode. Do not enable this feature unless instructed to do so by a Metrologic representative.
0
0
*Scanability Off
12345 11116 7 When this option is enabled, the scanner will enter scan count test mode. The firmware number of the scanner will also be transmitted to the host device. Do not enable this feature unless instructed to do so by a Metrologic representative.
*Scan Count Mode Off
12345 11107 5 Do not enable this feature unless instructed to do so by a Metrologic representative.
0
0
C-9
12345 11106 8 Do not enable this feature unless instructed to do so by a Metrologic representative.
Page 38
Extended Depth of Field
0
12345
21600
Close Depth of Field
8
0
Do not change this setting unless instructed to do so by a Metrologic representative.
12345
21610
21620
6
Do not change this setting unless instructed to do so by a Metrologic representative.
*Normal Depth of Field
0
12345
7
Do not change this setting unless instructed to do so by a Metrologic representative.
C - 10
Page 39
Intercharacter Delay
0
12345
31132
Intercharacter Delay
0
1
12345
31112
3
If the host device does not require an intercharacter delay, choose this option.
The time specified represents the interim of time in between transmission of characters.
RS-232 - None Parallel - None
RS-232 - 5 mesc Parallel - 2 mesc
OCIA - None KB Wedge - None
Intercharacter Delay
Intercharacter Delay
0
12345
31122
0
2
12345
31102
4
The time specified represents the interim of time in between transmission of characters.
The time specified represents the interim of time in between transmission of characters. RS-232 - *1 msec Parallel - *1 msec
OCIA - 5 mesc KB Wedge - 10 mesc
RS-232 - 20 mesc Parallel - 5 mesc
OCIA - *1 msec KB Wedge - *1 msec C - 11
OCIA - 20 mesc KB Wedge - 100 mesc
Page 40
Intercharacter Delay
12345
31700
Intercharacter Delay
The time specified represents the interim of time in between transmission of characters.
12345 31152 9 The time specified represents the interim of time in between transmission of characters.
RS-232 - Reserved OCIA - Reserved Parallel - Reserved KB Wedge - 5 mesc
RS-232 - Reserved Parallel - Reserved
Intercharacter Delay
Intercharacter Delay
0
0
12345
31162
2
0
8
0
12345
OCIA - Reserved KB Wedge - 50 mesc
31142
The time specified represents the interim of time in between transmission of characters.
0 The time specified represents the interim of time in between transmission of characters.
RS-232 - Reserved OCIA - Reserved Parallel - Reserved KB Wedge - 25 mesc
RS-232 - Reserved Parallel - Reserved C - 12
OCIA - Reserved KB Wedge - 75 mesc