Page 21

CONFIGURATION OF THE MS6130 HAND-HELD To perform matching procedure refer to page 18. Before the MS6130 scanner ships from the factory, the factory programs the scanners to a set of default settings. These default settings can be found in the MS4120 Programming Guide. The default settings have an asterisk that appears before the brief definition located near the bar code. Once RF communication establishes, change the default settings of your scanner to meet your individual scanning needs. Configure the scanner by scanning the Transmitter Enter/Exit Program Mode bar code and the appropriate bar codes in the MS4120 Programming Guide. For example, to program the MS6130 not to read ITF (Interleaved 2 of 5) bar code types: •

With the MS6130, scan the Enter/Exit Program Mode bar code in the MS4120 Programming Guide, the Disable ITF bar code, then the Enter/Exit Program Mode bar code again. Note: When the MS6130 is in program mode, never scan any of the RS-232 or light pen options marked with an “R”. The list of options is in the Default Settings of the Transmitter and “MX” Receiver section of this guide when using the MS4120 Programming Guide. The MS6130 is in program mode when scanning the Enter/Exit Program Mode bar code in the MS4120 Programming Guide.

15

Page 22

ENABLING THE MS700I/MS720I SCANNER’S RF LOW SPEED OPTION Before beginning this procedure, perform all steps in the sections, Matching the Transmitter to the Receiver and Configuration of the MS700i/MS720i with “MX”. Use the MS700i/MS720i scanner to scan the following bar codes. 1.

Temporarily cover the bar code below Step 3. Scan the following bar code to enter program mode. (The MS700i scanner will beep three times):

Enter/Exit Program Mode for the Receiver

0

12345

66666

7

2.

Temporarily cover the bar code in Step 1. Scan the Enable RF Low Speed Option bar code below Step 3.

3.

Exit program mode by scanning the bar code in Step 1 again.

Enable RF Low Speed Option

0

16

12345

12915

5

Page 23

CHANGING THE ID In order for the MS6130 to send data to the correct receiver, they must have a matching ID number. The ID number is the serial number of the receiver. When the matching procedure is completed, the receiver will accept data only from a MS6130 that has the matching ID number. Each receiver is programmed with its serial number before it leaves the factory.

1.

To program a new ID for the receiver, HANDSET (Version 1.14 or greater) must be used. Type the following at the DOS prompt: HANDSET /X

2.

Power up the receiver, but DO NOT scan any bar codes.

3.

Select “Enter Program Mode”. Select the appropriate SERIAL PORT (COM 1 or COM 2) on the PC. Make sure the Receiver is connected to the SERIAL PORT selected.

4.

Select “Get Scanners Settings”. A screen will appear showing all of the options available.

5.

Using the arrow keys, move down to the section labeled “Metro ID#”. Locate the serial number on the case of the receiver. Enter this 10digit number into the “Metro ID#” section.

6.

Press the “F5" key to program the receiver.

7.

The receiver will beep when programming is completed. The receiver is now programmed with its proper ID. Exit HANDSET by pressing “F9" and then press “7".

8.

Power Down the receiver.

17

Page 24

MATCHING PROCEDURE With the MS6130, scan the following bar codes starting from the top down:

Transmitter Enter/Exit Program Mode

*

*

Recall Defaults

D

F

1

Enable RF Communications

R

3

5

Transmitter Enter/Exit Program Mode

*

*

Locate the model label on the case of the receiver. Scan the serial number bar code. The receiver and MS6130 are now matched. For information on how to configure the receiver, refer to the appropriate section in this guide.

Note: If using more than one MS6130 with one receiver, perform the above procedure for each MS6130. Since each MS6130 has the same ID number, the receiver will accept data from all of the scanners

18

Page 25

PARTS OF THE MS6130 HAND-HELD BAR CODE SCANNER Becoming familiar with the features of the MS6130 hand-held scanner will help when operating one of these scanners. The illustration and list explain the pertinent parts.

Green and Red LED

Replaceable Battery Pack Output Window

Battery Charge Contacts Reactivation Switch

Infra-red (IR) Sensor

Figure 4: Scanner Parts

Battery Charge Contacts

Receptacle for the battery charger.

Reactivation Switch

Turns the unit on after a timeout. Press the button from the bottom.

Green and Red LEDs

When the red LED is on, the laser is on. If the green LED flashes on, the scanner has read a bar code successfully. Communication to the host is complete when the receiver beeps.

Infrared Object Sensor

When a specified time has elapsed without any scanning, the unit will enter a “standby” mode. To reactivate the unit, remove the current object and present an object in front of the output window again.

Output Window

This aperture emits laser light.

19

Page 26

COMPONENTS OF THE MS6130 SERIES STAND The following are the components used to build the MS6130 series stand (MLPN: 45880). 1

1.

Cradle

2.

Stand Charger Pack

3.

Pole Cover

2 10

8 3

4.

Flex pole

5.

Stand Base Cover

6.

Stand Base

7.

Charger Transformer

8.

Charger Pack Screws

CABLE CONNECTS THROUGH OPENING

4

7

5

9.

Mounting Screws 9

10. Lock Washer 6

Figure 5: Scanner Parts

20

Page 27

INSTALLATION OF THE MS6130 SERIES STAND Refer to for numbered components on the previous page 1.

Use the stand base (6) as a template to drill and mount the base to the counter using the mounting screws (9) provided.

2.

Feed the wire from the transformer (7) through the slot in the base cover (5) approximately 9" of the wire.

3.

Press the base cover (5) over the base (6).

4.

Attach the flex pole (4) to the base (6).

5.

Slide the flex cover (3) over the pole (4) and wire.

6.

Attach the cradle (1) to the flex pole (4) using the lock washer (10) to connect the transformer.

7.

Insert the transformer plug into the connector inside the stand charger pack (2).

8.

Clip the charger pack to the bottom of the cradle (1) lock in place using two screws (8).

Stand LED Indicators (with the scanner in the stand) No LED indicates trickle charge and the green LED indicates fast charge. To change from trickle charge to fast charge, simply lift the scanner from the stand and replace. Note: When both scanner LEDs blink, it is an indication of a low battery.

21

Page 28

INSTALLATION OF THE 6000 SERIES UNIVERSAL CHARGING STAND MLPN: 45558 - 115V, 45559 - 230V and 45560 - 240V (UK)

Transformer

Green LED (Charge Status)

Red LED (Power)

Figure 6: Universal Charging Stand

PERMANENT COUNTER TOP INSTALLATION 1.

Separate weighted base from rotating base by removing the (4) four screws.

2.

Use the rotating base as a drill template.

3.

Use the (4) four wood screws provided to mount the base to the counter top securely.

4.

Snap the cup assembly to the base. Note: For non-permanent installation, snap the cup assembly onto the weighted base CHARGE STATE

22

CHARGE LED STATUS

Battery Absent

LED off

Charge Pending

LED on for 0.125sec, off for 1.375sec

Fast-Charge

LED on

Charge Complete and Top-Off

LED on for 0.125 sec, off for 0.125sec

Page 29

NICD BATTERY CHARGER WITH RECONDITIONING FEATURE MLPN: 45561 - 115V and 45562 - 230V How to Recondition Transformer

Discharge Cycle Switch

1. Place the scanner into the charge stand. 2. Push the stand tilt cup in the extreme down position to expose the hole for the discharge cycle switch.

Red LED (Power)

Green LED (Charge Status)

Figure 7: Reconditioning

3. Use a pin to push the discharge cycle switch located beneath the hole. 4. When the discharge mode is initiated the green LED flashes.

RECOMMENDED USE To maintain charge capacity, the NiCd batteries must be discharged fully before charging. We call this process reconditioning. Recondition if: • The batteries were not used within 20 days • The batteries were not discharged (approximately two hours of continuous operation) at least once a week • Low battery indicators: • Both LED’s on the scanner blink • The scanner quietly beeps twice while scanning Recondition once a week if: • The batteries do not get discharged for more than 20% (approximately ½ hour) of their capacity before recharging. Recondition once every two weeks if: • The batteries do not get discharged for more than 50% (approximately 1 hour) of their capacity before recharging. Note: The day to day usage of the NiCd batteries will determine the frequency of the discharges (reconditioning). Charge State Battery Absent Charge Pending Discharge-BeforeCharge Fast-Charge Charge Complete TopOff

CHG LED Status LED off LED on for 0.125sec, off for 1.375sec LED on for 1.375sec, off for 0.125sec LED on LED on for 0.125 sec, off for 0.125sec

23

Page 30

VISUAL INDICATORS The scanner has red and green LEDs. When the scanner is on, the LEDs indicate the status of the scan and scanner. No Red or Green

The scanner will turn off if the scanner has been dormant for a specified time. To reactivate the unit, direct the output window up then down toward the bar coded product. If the unit has been dormant for longer than 10 minutes, reactivating the unit by pressing the button on the side of the MS6130 will be necessary.

Red Flash; Green Flash;

When the scanner first receives power, the steady red LED will flash, followed by the green LED.

Steady Red

When the laser is on, the red LED will also be on. This occurs when an object is in the scan field. If the scanner does not detect a bar code within approximately 2.5 seconds, the red LED will shut off indicating that the laser is no longer on. If the red LED remains on for longer than 7.5 seconds, then the scanner is in program mode.

Steady Red; Green Flash

When the scanner successfully reads a bar code, the green LED will flash. If the green LED does not flash, then the bar code read was not successful.

Repetitive Red Flashes

When the red LED flashes several times while it lays upon a stationary surface, then an object is within the scan field and is activating the IR sensor. This can occur even while the scanner is lying upon the counter or cradle. To eliminate this disturbance, direct the scan window toward a different location.