Page 11

CONNECTIONS OF THE KEYBOARD W EDGE “MX” INTERFACE TO THE PC Version 17 only MX003 Scanner Interfaces with a suffix of “17" are Keyboard Wedge versions used to interface with a PC and keyboard. 1.

Turn off the PC.

2.

Plug the “MX” receiver adapter cable to the PC keyboard port.

3.

Plug the keyboard into the “MX” receiver adapter cable.

4.

Power up the PC. ®

MS6130 with Liberty RF Scanner Interface (Transmitter) Optional Adapter

“MX” Receiver adapter Cable Host System Figure 3: Connecting the “MX” to a PC and keyboard

To maintain compliance with applicable standards, all circuits connected to the unit must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. The following statement is applicable if the scanner will receive power from a host device such as a computer system. Caution: To maintain compliance with standards CSA C22.2 No. 950/UL 1950 and norm EN60950, the power source must meet applicable performance requirements for a limited power source.

5

Page 12

CONNECTIONS OF THE MS700I/MS720I WITH “MX” TO THE HOST DEVICE To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1.

Turn off the host system.

2.

Connect the 25-pin D-type connector on the MS700i/MS720i scanner’s head cable to the communication cable. Connect the other end of the communication cable to the host device. If the scanner will not receive power from a transformer, skip to Step 5.

3.

If the scanner will receive power from an external power source, check the AC input requirements of the transformer to make sure the voltage matches the AC outlet. The socket-outlet should be near the equipment and easily accessible.

4.

Plug the transformer into the side of the female D-type connector located on the communication cable. Plug the transformer into the AC outlet to supply power to the scanner.

5.

Power up the host system.

6.

Attach the “MX” to the MS700i/MS720i scanner via the LSO cable that terminates to a 10-pin modular connector.

Note:

When the MS700i/MS720i scanner first receives power, the LEDs will flash and then the scanner will beep once. After the scanner performs this startup sequence, the green LED will remain on for a specified time showing that the laser is on. Refer to the MS700i and MS720i Laser Bar Code Projection Scanner Installation and User’s Guide for information on how to operate the scanner.

To maintain compliance with applicable standards, all circuits connected to the unit must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. The following statement is applicable if the scanner will receive power from a host device such as a computer system. Caution: To maintain compliance with standards CSA C22.2 No. 950/UL 1950 and norm EN60950, the power source must meet applicable performance requirements for a limited power source.

6

Page 13

CONFIGURATION OF THE MS700I/MS720I WITH “MX” To perform matching procedure refer to page 18. Once the transmitter is assigned an ID number, configure the S700i/MS720i to accept RF communication. Although the changes made in this section effect the receiver, the MS6130 performs all scanning. 1.

Scan the following bar code to enter the receiver’s program mode. (The MS700i/MS720i will beep three times):

Enter/Exit Program Mode for the Receiver

0

2.

1 2 3 4 5

6 6 6 6 6

7

Enable the RF interface by scanning the following bar codes in order:

R

0

1

L

P

1

H

H

1

3.

Exit program mode by scanning the bar code in Step 1 again.

4.

Proceed to the procedure on the next page.

7

Page 14

CONFIGURATION OF THE MS700I/MS720I WITH “MX” TO THE HOST SYSTEM To perform matching procedure refer to page 18. Before the MS700i/MS720i scanner ships from the factory, the factory programs the scanner to a group of default settings noted in the ScanSelect™ Scanner Programming Guide. An asterisk marks each default setting. The asterisk appears before the brief definition located near the bar code. Once RF communication establishes, change the default settings of your scanner to meet your individual scanning needs or your host system’s communication requirements. Modify the scanner's settings by entering the program mode and scanning the appropriate bar codes that appear in the ScanSelect Scanner Programming Guide. Note: When the Load Defaults bar code in the ScanSelect Scanner Programming Guide is chosen, it will automatically disable the RF low speed option. For the MS6130 to communicate to the MS700i/MS720i scanner, re-enable the RF Low Speed Option (refer to the procedure above).

8

Page 15

CONFIGURATION OF THE “MX” TO THE SCANPAL® DATA COLLECTOR To perform matching procedure refer to page 18. The RS-232 parameters marked with an asterisk ( * ) in the charts are the default settings of the “MX”. The charts are in the Default Settings of the MS6130 and “MX” Receiver section of this guide. To communicate with each other properly, the “MX” and ScanPal must have matching RS-232 parameters. However, the Enter/Exit Program Mode bar code in the MS4120 Programming Guide will not cause your “MX” to enter or exit program mode. Scan the Enter/Exit Program Mode for the Receiver bar code in the following procedure. Before completing RF communication, program the ScanPal to the same ® settings as the IBM PC XT, AT or PS/2 compatible computer. Once completed and the receiver and MS6130 have the same assigned ID number, configure the “MX” to the same settings as ScanPal. 1.

Program the ScanPal to the same settings as the PC. ® (Refer to the Programming the ScanPal section in the ScanPal Data Collector Installation and User’s Guide)

2.

Scan the following bar code to enter program mode. (The “MX” receiver will beep three times): Enter/Exit Program Mode for the Receiver

0

12345

66666

7

3.

Scan the appropriate communication options in the MS4120 Programming Guide.

4.

Exit program mode by scanning the bar code in Step 1 again. Note: Scan the Enter/Exit Program Mode for the Receiver bar code and exit program mode if the PC uses the same parameters as the default settings of ScanPal. Default to ScanPal Communication Parameters

I

B

5

9

Page 16

CONFIGURATION OF THE “MX” TO THE RS-232, LIGHT PEN OR KEYBOARD WEDGE HOST SYSTEM To perform matching procedure refer to page 18. The light pen, RS-232 and Keyboard Wedge parameters marked with an asterisk ( * ) in the charts are the default settings of the “MX”. The charts are in the Default Settings of the Transmitter and “MX” Receiver section of this guide. To communicate with a host system properly, program the “MX” to match the host system’s requirements. However, the Enter/Exit Program Mode bar code in the MS4120 Programming Guide will not cause your “MX” to enter or exit program mode. Scan the Enter/Exit Program Mode for the Receiver bar code in the following procedure. Once the MS6130 is assigned an ID number, configure the “MX” to the correct communication protocol. 1.

Scan the following bar code to enter program mode. (The “MX” receiver will beep three times): Enter/Exit Program Mode for the Receiver

0

2.

12345

66666

7

Scan the following bar code to confirm the receiver is using the original factory settings. Recall Defaults

D

F

1

3.

Scan the appropriate communication options in the MS4120 and MS951 Programming Guides.

4.

Exit program mode by scanning the following bar code. (The “MX” receiver will beep three times): Enter/Exit Program Mode for the Receiver

0

10

12345

66666

7

Page 17

KEYBOARD WEDGE (KB) INTERFACE Scan the ENABLE KB WEDGE INTERFACE bar code if your communication requirement is keyboard emulation. The scanner will provide keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent. Enable Keyboard Wedge Interface

R

2

4

KB Parameter - Keyboard Type The following bar codes are used to define the type of keyboard in use. If necessary, scan the appropriate bar code. ®

** AT Keyboard (includes IBM PS/2: Models 50, 55, 60, 80)

L

P

3

XT Keyboard

L

P

4

Enable IBM PS/2 Keyboard (Models 30, 70, 8556)

S

H

4

** Disable IBM PS/2 Keyboard (Models 30, 70, 8556)

S

H

3

Enable Single-Ended Keyboard Emulation

R

5

7

11

Page 18

KEYBOARD WEDGE (KB) INTERFACE (CONTINUED) KB Parameter – Keyboard Type The following bar codes are used to define the keyboard country type. If necessary, scan the appropriate bar code. ** USA Keyboard

B

R

8

UK Keyboard

B

R

2

France Keyboard

B

R

3

Germany Keyboard

B

R

4

Italy Keyboard

B

R

5

Spain Keyboard

B

R

6

Belgium Keyboard

B

R

1

IBM KB4700 Financial Keyboard

B

R

7

Swiss Keyboard

B

R

9

Reserved

B

12

R

A

Page 19

KEYBOARD WEDGE (KB) INTERFACE (CONTINUED) Reserved

B

R

B

Reserved

B

R

C

Reserved

B

R

D

Reserved

B

R

E

Reserved

B

R

F

KB Parameter - Caps Lock Mode When Caps Lock is used on the keyboard, choose ENABLE CAPS LOCK. Once enabled, the scanner will simulate Caps Lock keyboard input. This mode will not work with all keyboard types.

Enable Caps Lock

R

6

**Disable Caps Lock

R

To detect automatically if Caps Lock is used, enable AUTO-DETECTION CAPS LOCK MODE. This will only work with an AT computer.

4

4

7

Enable Auto Detection Caps Lock Mode

R

6

8

**Disable Auto Detection Caps Lock Mode

R

6

9

13

Page 20

KEYBOARD WEDGE (KB) INTERFACE (CONTINUED) KB Parameter - Alt Mode When this option is enabled, the scanner will duplicate this keyboard sequence: Hold down the Alt key; type the decimal number that corresponds to the appropriate keyboard character. Caution should be observed when using Alt mode because a scanner to host application conflict may occur if the host software application uses the Alt key as a “Hot” key.

Enable Alt Mode

H

H

3

**Disable Alt Mode

H

H

4

KB Parameter - Inter Scan Code Delay (AT and PS/2 Modes) The time specified with an interscan code delay bar code represents the amount of time between individual 9 bit scan codes. Each character of a bar code takes between two and twelve of these scan codes to be passed through to the PC via the keyboard interface. This parameter may need to be adjusted for operation with certain PC keyboard BIOS’s. Network operating systems often use microprocessor time slices to service network information requests instead of the keyboard interface. While not an issue with manually entered keystrokes, this timing can be critical with automatic scanner data entry. Interscan code delays can be a useful system tuning tool in these environments.

** 800 Microsecond Delay

O

C

8

7.5 Millisecond Delay

O

C

9

15 Millisecond Delay

O

C

7

KB Parameter - XT - Clean-Up Bit Some keyboard BIOS's require a "cleanup bit" to be transmitted before an actual scan code being clocked over to the motherboard. Enabling this feature will cause the scanner to send this extra bit to the host computer. More commonly found on older XT style BIOS's, and some AT BIOS's. (required by some NEC 80286 machines).

Enable Cleanup Bit

H

1

** Disable Cleanup Bit

H

14

H

H

2