Page 31

AUDIBLE INDICATORS When the scanner and “MX” receiver are in operation, they provide audible indications. These sounds indicate the status of the scan and scanner. One Beep

When the “MX” Receiver first receives power, the unit will beep once. If the scanner successfully reads a bar code, the green light will flash. If the “MX” receiver successfully receives the data from the MS6130, the “MX” will beep once.

Razzberry Tone

If, upon power up, the scanner emits a razzberry tone, then the scanner has failed diagnostics. The “MX” receiver will emit a razzberry tone if an invalid bar code is scanned while the receiver is in program mode. The “MX” receiver can be programmed to emit a razzberry tone when the timeout occurs during communication between the host and receiver. Refer to the MS4120 Programming Guide section, Audible Indicators for Communication Timeouts to program this feature.

Two Beeps

The MS6130 scanner will quietly beep twice when scanning a bar code if the batteries become low.

Three Beeps

When scanning the MS6130 Enter/Exit Program Mode bar code in the MS4120 Programming Guide, the green LED will flash three times while the scanner simultaneously beeps three times. When exiting the program mode, the same visual and audible indications will occur. After this sequence is completed, the red LED will turn off. When scanning the Enter/Exit Program Mode for the Receiver bar code, the “MX” receiver will beep three times to indicate it is in or exiting out of the program mode.

(continued next page)

25

Page 32

AUDIBLE INDICATORS (CONTINUED) The “MX” receiver can be programmed to emit three beeps when the timeout occurs during communication between the host and receiver. Refer to the MS4120 Programming Guide section, Audible Indicators for Communication Timeouts to program this feature. There are four settings available for the tone of the beep for the receiver. Refer to the MS4120 Programming Guide section, Beeper Tones to program the feature to change the tone or turn the beeper off.

26

Page 33

LABELS The MS6130 scanner is either a CDRH Class II laser system or an IEC Class 1 Laser System. Your unit will have a CDRH Class II caution label or LASERKLASSE 1 label affixed below the model number label. The model number/avoid exposure label is located on the bottom of the scanner’s head. The following are examples of these labels:

MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning.

1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the output window.

27

Page 34

TROUBLESHOOTING 1.

The receiver can receive data from a MS6130 with its own ID or 10 zeroes. It’s own ID can be received all the time. When using 10 zeroes, the first scan the receiver gets must have 10 zeroes as its ID and from that point on the receiver will accept both ID’s. Power down the receiver. Using the MS6130, scan the bar codes from section 9 in the Matching MS6130 to the Receiver section and use the following bar code as the ID number. Scanner ID Number

0

0

0

0

0

0

0

0

0

0

Note: Use this bar code for troubleshooting purposes only. 2.

Power up the receiver.

3.

If the user is trying to match a new ID to the receiver and the receiver is powered up, the receiver will beep 3 times if the ID number it receives matches its current ID.

4.

When the MS6130 is in program mode, never scan any of the RS-232 or light pen options marked with an “R”. The list of options is in the Default Settings of the MS6130 and “MX” Receiver section of this guide when using the MS4120 Programming Guide. The MS6130 is in program mode when scanning the Enter/Exit Program Mode bar code in the MS4120 Programming Guide. If a receiver option is chosen while the MS6130 is in program mode, RF communication between the MS6130 and receiver may terminate. If this occurs, the only way to reestablish RF communication is by performing all the RF configuration procedures again.

28

Page 35

APPENDIX A Specifications RF Link Characteristics Frequencies:

One of the following depending on the country of operation: 418 MHz 434 MHz 912 MHz

Bandwidth:

220 kHz

Modulation:

FM

Certification:

No FCC licensing required

RF Protocol:

One way data transmission Transmission time at a maximum of 100 ms 50K baud data rate Dedicated transmitter(s) to receiver link

Operating Range:

Up to 30 feet (conditions permitting)

Specifications subject to change without notice

MS6130 Bar Code Scanner Specifications UL Listed:

US and Canada

FCC ID:

LW5613 (912 MHz only)

RF Output Power:

20 uW max. (912 MHz only)

Current:

Supplied by rechargeable/replaceable batteries

Antenna:

Integral

Dimensions: Length

216 mm [8.5”]

Width

63 mm [2.5”] Head and 48 mm [1.9”] Handle

Height

28 mm [1.1”]

Weight:

289 g [10.5 oz]

Maximum Radiant Power:

0.9 mW Peak

VLD Wavelength:

630 nm to 680 nm

29

Page 36

APPENDIX A (CONTINUED) MX003 Series Scanner Interface Specifications FCC ID:

LW5003

Operating Voltage:

5Vdc

Antenna:

Integral

Dimensions:

90 mm [3.54"] x 50 mm [1.97"] x 24 mm [0.94"]

Weight:

80.3 g [2.8 oz]

UL Listed:

US and Canada

Model Number

Operating Frequency

Data Interface RS-232 Light Pen

MX003

912 MHZ

✓

MX003-17

912 MHZ

MX0033

418 MHZ

MX0033-17

418 MHZ

MX0034

434 MHZ

MX0034-17

434 MHZ

Data Interface Keyboard Wedge

✓ ✓ ✓ ✓ ✓

Model designation may include the suffix “J” used to indicate the addition of an audio signal output jack.

30

Page 37

APPENDIX A (CONTINUED) Specifications of Battery Pack Battery Type:

“AA” NiCd Rechargeable

Configuration:

3 Batteries/Pack

Nominal Voltage:

3.6 VDC

Maximum Voltage:

4.8 VDC

Capacity:

600 mA

Charge Cycles:

Over 500 Full Charge/Discharge

Charge Time:

4 Hours

Short Circuit Protection:

Auto/Reset Fuse 1.7A Hold Current

Temperature Characteristics (Degrees Celsius) of each Cell: Charge:

0 to +45

Discharge:

-20 to +60

Storage (Long):

-30 to +35

UK Compliance To charge the batteries in the MS6130 - 418MHz, remove the ESD cover from the bottom of the unit. Refer to the battery charge rate for additional information. After a full charge, replace the cover over the battery contacts. The cover should remain in place during operation

31

Page 38

APPENDIX B Default Settings of the MS6130 and “MX” Receiver Before the MS6130 hand-held scanner and “MX” Receiver ships from the factory, the factory programs the scanners to a group of default settings. An asterisk ( * ) in the charts on the following pages marks the default settings of the units. If an asterisk is not in the default column then the default setting is Off or Disabled. The MS6130 and “MX” receiver do not support every parameter. For those parameters that are a transmitter function, a letter “T” will appear in the second column of the charts, for the “MX”, the letter “R”. RS-232, light pen and keyboard wedge emulation does not support every parameter. If your host device’s communication supports a parameter listed in the charts on the following pages, a check mark will appear. In order for the “MX” receiver to communicate with your RS-232, light pen or keyboard wedge host device properly, program it to meet your individual scanning needs. Since each host system is unique, change the default settings to match your host system requirements. To modify default settings, refer to the MS4120 and MS951 Programming Guides. Note:

If your “MX” Interface is connected to a MS700i/MS720i scanner, use the bar codes in the ScanSelect Programming Guide to match your scanner’s settings to the host system requirements.

T - Transmitter (MS6130 Hand-held) R - Receiver (“MX”) Parameter

T - Transmitter R - Receiver

Default

RS-232

Light Pen

*

✓

✓

T

✓

✓

T

✓

✓

✓

✓

✓

✓

Enter/Exit Program Mode

T

Recall Defaults Enter Program Mode After Any Scan Enter Program Mode Only on First Scan Short Range Activation Out of the Stand Long Range Activation Out of the Stand Short Range Activation in the Stand

R

32

T

T T

*

Page 39

APPENDIX B (CONTINUED) T - Transmitter R - Receiver

Default

RS-232

Light Pen

Long Range Activation in the Stand

T

*

✓

✓

Normal Scan

T

*

✓

✓

Pulsing Scan

T

✓

✓

Custom Scan

T

✓

✓

Green LED Rescan Indicator

T

✓

✓

Short Same Symbol Rescan

T

✓

✓

Long Same Symbol Rescan

T

✓

✓

Alternate Beeper Tone 1

R

✓

✓

Alternate Beeper Tone 2

R

✓

✓

Alternate Beeper Tone 3

R

✓

✓

No Beeper Tone

R

✓

✓

Two Second Time-out

R

✓

No Two Second Timeout

R

Parameter

*

*

*

✓ ✓

Razzberry Tone on Timeout

R

No Tone on Timeout

R

Three Beeps on Timeout

R

Beep Before Transmit

R

Beep After Transmit

R

Baud Rate

R

9600

✓

Parity

R

Space

✓

8 Data Bits

R

7 Data Bits

R

RTS/CTS

R

Character RTS/CTS

R

Message RTS/CTS

R

✓

ACK/NAK

R

✓

XON/XOFF

R

✓

No Intercharacter Delay 1 Millisecond Intercharacter Delay 5 Millisecond Intercharacter Delay 25 Millisecond Intercharacter Delay

R

*

✓ ✓

*

✓ ✓

✓ *

✓ ✓

*

*

✓

✓

R

✓

R

✓

R

✓

33

Page 40

APPENDIX B (CONTINUED) Parameter

T - Transmitter R - Receiver

Default

RS-232

Light Pen

✓

DTR Input

R

Carriage Return

R

*

✓

Line Feed

R

*

✓

ETX Suffix

R

✓

Tab Prefix

R

✓

Tab Suffix

R

✓

Prefix ID for UPC/EAN

R

✓

Suffix ID for UPC/EAN

R

✓

Bars High

R

Spaces High

R

Transmit as Scanned

R

Transmit as Code 39

R

✓

Poll Light Pen 5 Volts

R

✓

No Poll Light Pen

R

*

UPC

T

*

✓

✓

EAN

T

*

✓

✓

Code 39

T

*

✓

✓

Codabar

T

*

✓

✓

Code 128

T

*

✓

✓

Code 93

T

*

✓

✓

Interleaved 2 of 5 (ITF)

T

*

✓

✓

MSI Plessey Decode

T

✓

✓

Enable Code 11 Decode

T

✓

✓

Enable Airline 2 of 5

T

✓

✓

Full ASCII Code 39

T

✓

✓

Italian Pharmaceutical

R

✓

✓

Minimum 1 Character Code Length

T

✓

✓

Minimum 3 Character Code Length

T

✓

✓

Minimum 6 Character Code Length

T

✓

✓