DESIGN SPECIFICATIONS MS3780 Operational Light Source:

Visible Laser Diode (VLD) @ 650 nm

Laser Power:

1.1 mW (Peak)

Normal Depth of Field:

25 mm - 280 mm (1"- 11")

Reduced Depth of Field:

25 mm - 150 mm (1"- 6")

0.33 mm (13 mil) bar code

Omni Scan Scan Speed: No. of Scan Lines:

1333 scan lines per second 20

Single-Line Scan Speed: No. of Scan Lines:

67 scan lines per second 1

Motor Speed:

4000 RPM

Min Bar Width:

0.127 mm (5.0 mil)

Decode Capability:

All standard 1-D bar codes including RSS-14, RSS-Expanded, and RSS-14 Limited

System Interfaces:

RS232, Keyboard Wedge, Stand-Alone Keyboard, Light Pen Emulation, RS485, USB (low speed and full speed), OCIA

Print Contrast: No. Characters Read: Beeper Operation: Indicators (LED): Termination: Cable:

35% minimum reflectance difference Up to 80 data characters Maximum number will vary based on symbology and density. 7 tones or no beep Blue = laser on, ready to scan White = good read, decoding 10 position modular RJ45 connector Application Dependent

Mechanical Scanner Length:

189 mm (7.44")

Scanner Width:

65 mm (2.56")

Scanner Height:

73 mm (2.88")

Scanner Weight:

195 g (6.9 oz.)

Specifications subject to change without notice.

27

Page 32

DESIGN SPECIFICATIONS MS3780 Electrical Voltage Supply:

5VDC ± 0.25V

Operating Power:

1.375 W

Standby Power:

1.0 W

Operating Current:

275 mA typical at 5VDC

Standby Current:

200 mA typical at 5VDC

DC Transformers:

Class II; 5.2VDC @ 1A

For regulatory compliance information, see pages 41 - 43.

Environmental Operating Temperature:

-20°C to 40°C (-4°F to 104°F)

Storage Temperature:

-40°C to 60°C (-40°F to 140°F)

Humidity: Contaminants: Ventilation: Shock:

5% to 95% relative humidity, non-condensing Sealed to resist airborne particulate contaminants None required Withstands multiple drops from 1.5 meters

Specifications subject to change without notice.

28

Page 33

APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER

VERSION IDENTIFIER

MS3780

INTERFACE

9

OCIA and RS232 Transmit/Receive

11

RS485S and Full RS232

38

RS232 Low Speed USB*, Keyboard Emulation or USB Serial Emulation Mode

40

Full Speed USB

41

RS232/Light Pen Emulation

47

Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive

48

Stand Alone Keyboard and RS232 Transmit/Receive

120

USB and RS232 Transmit/Receive with EAS

®

S

Applicable for IBM Host applications.

The MS3780 scanner with Built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. Many RS232 configurable functions (e.g. formatting) available in other Metrologic scanners are also available as keyboard wedge functions. The following are the most important selectable options specific to the keyboard wedge. Keyboard Type • •

** AT (includes IBM® PS2 models 50, 55, 60, 80) IBM PS2 (includes models 30, 70, 8556)

Keyboard Country Type • • • • •

USA ** Belgium French German Hungarian

• • • • •

**

Default setting. For a complete list of default settings, see Default Settings Communication Parameters starting on page 30 of this guide. Refer to the MetroSelect® Configuration Guide (MLPN 00-02407) or MetroSet2’s help files for information on how to change the default settings.

Italian Japanese Russian Cyrillic Slovenian Spanish

• • • •

Swiss Swedish/Finnish Turkish United Kingdom

29

Page 34

DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is off or disabled. Every interface does not support every parameter. If the interface supports a parameter listed in the charts on the following pages, a check mark ( ) will appear in the column for that interface. PARAMETER

DEFAULT

UPC/EAN

*

Code 128

*

Code 93

*

Codabar

*

Interleaved 2 of 5 (ITF)

*

MOD 10 Check on ITF Code 11

*

Code 39 Full ASCII Code 39 MOD 43 Check on Code 39 MSI-Plessey MSI-Plessey 10/10 Check Digit MSI-Plessey MOD 10 Check Digit Paraf Support ITF Symbol Lengths

Variable

Minimum Symbol Length Symbol Length Lock

4 None

RSS14 Enable RSS14 ID “]e0”

*

RSS14 App ID “01”

*

RSS14 Check Digit

*

RSS Expanded Enable S

®

Applicable for IBM Host applications.

30

OCIA

USB

RS232*

LIGHT PEN

RS485S

KBW

Page 35

DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER

DEFAULT

OCIA

USB

RS232*

LIGHT PEN

RS485S

KBW

*

Expanded ID “]e0” RSS Limited Enable RSS Limited ID “]e0”

*

RSS Limited App ID “01”

*

RSS Limited Check Digit

*

Bars High as Code 39

*

Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS

*

DTS/NIXDORF NCR F NCR S Poll Light Pen Source Beeper Tone

Normal

Beep/Transmit Sequence

Before Transmit

Communication Timeout

None

Razzberry Tone on Timeout Three Beeps on Timeout No Beeps on Timeout

*

Enter Power Save Mode

5 mins.

Same Symbol Rescan Timeout: 500 msecs Programmable in 50 msec steps (MAX 6.35 seconds)

*

Intercharacter Delay Programmable in 1 msec steps (MAX 255 msecs) Number of Scan Buffers S

1 msecs 10 msecs in KBW 1

®

Applicable for IBM Host applications.

31

Page 36

DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER Transmit UPC-A Check Digit

DEFAULT

*

Transmit UPC-E Check Digit Expand UPC-E Convert UPC-A to EAN-13 Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 Transmit UPC-A Number System

*

Transmit UPC-A Manufacturer ID#

*

Transmit UPC-A Item ID#

*

Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop/Start Characters Transmit Mod 10/ITF Transmit MSI-Plessey Check Characters Parity

Space

Baud Rate

9600

8 Data Bits 7 Data Bits

*

Stop Bits

2

Transmit Sanyo ID Characters S

Applicable for IBM® Host applications.

32

OCIA

USB

RS232*

LIGHT PEN

RS485S

KBW

Page 37

DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER

DEFAULT

OCIA

USB

RS232*

LIGHT PEN

RS485S

KBW

Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Transmit AIM ID Characters STX Prefix ETX Suffix Carriage Return

*

Line Feed - disabled by default in KBW

*

Tab Prefix Tab Suffix “DE” Disable Command “FL” Laser Enable Command DTR Handshaking Support RTS/CTS Handshaking

*

Character RTS/CTS Message RTS/CTS XON/XOFF Handshaking ACK/NAK Two Digit Supplements as code 39

Five Digit Supplements as code 39

Bookland as code 39

977 (2 digit) Supplemental Requirement S

®

Applicable for IBM Host applications.

33

Page 38

DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER

DEFAULT

Supplements are not Required

*

Two Digit Redundancy

*

OCIA

USB

RS232*

LIGHT RS485S PEN

Five Digit Redundancy

100 msec to Find Supplement Configurable in 100msec steps (MAX 800 msec)

* as code 39

Coupon Code 128 Configurable Code Lengths

7 avail.

Configurable Prefix Characters

10 avail.

Configurable Suffix Characters

10 avail.

Prefixes for individual Code Types Editing Inter Scan-Code Delay Configurable (100 µsec steps)

800 µsec

Function/Control Key Support Minimum Element Width Configurable in 5.6 µsec steps

1 msec

*

Normal Depth of Field Reduced Depth of Field S

®

Applicable for IBM Host applications.

34

KBW

Page 39

UPGRADING THE FIRMWARE CONFIGURATION MODES The MS3780 Series scanner has three modes of configuration. •

Bar Codes The MS3780 can be configured by scanning the bar codes included in the Metrologic Single-Line Configuration Guide (MLPN 00-02544) or the Supplemental Configuration Guide (MLPN 00-02281). These manuals can be downloaded FREE of charge from Metrologic’s website (www.metrologic.com).

•

MetroSet2 This user-friendly Windows-based configuration program allows you to simply ‘point-and-click’ at the desired scanner options. This program can be downloaded FREE of charge from Metrologic’s website (www.metrologic.com) or set-up disks can be ordered by calling 1-800-ID-METRO.

•

Serial Configuration This mode of configuration is ideal for OEM applications. This mode gives the end-user the ability to send a series of commands using the serial port of the host system. The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Single-Line Configuration Guide (MLPN 00-02544).

35

Page 40

UPGRADING THE FIRMWARE The MS3780 Fusion is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and Metrologic's MetroSet2 software . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is also required to complete the upgrade. PowerLink Cable #54-54014 is required when using RS232 for the upgrade process. This cable can be ordered from Metrologic at 1-800-ID-METRO. Do not use the standard cable supplied with keyboard wedge or RS485 scanner interface kits. If using USB for the upgrade process, the standard USB Type A cable provided with the scanner can be used.

To upgrade the firmware in the MS3780: 1.

Plug the scanner into a serial communication port on the host system.

2.

Start the MetroSet2 software.

3.

Click on the plus sign (+) next to POS Scanners to expand the supported scanner list.

4.

Choose the Fusion from the list.

5.

Click on the Configure Fusion/3780 Scanner button.

6.

Choose Flash Utility from the options list located on the left side of the screen.

7.

Click on the Open File button in the Flash Utility window.

8.

Locate and open the flash upgrade file supplied by Metrologic.

9.

Select the COM port that the scanner is connected to on the host system.

10. Verify the settings listed in the Flash Utility window. 11. Click on the Flash Scanner button to begin the flash upgrade. 12. A message will appear on the screen when the upgrade is complete.

Metrologic's customer service department can be reached at 1-800-ID-METRO or 1-800-436-3876. MetroSet2 is available for download, at no additional cost, from http://www.metrologic.com/corporate/download.