The text of a manual · part 4 of 6
MS3780 Fusion Omni/Single Line Scanner Installation and User's Guide, pages 31 to 40
Pages 31 to 40 of 56
The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS3780
Page 31
DESIGN SPECIFICATIONS MS3780 Operational Light Source:
Visible Laser Diode (VLD) @ 650 nm
Laser Power:
1.1 mW (Peak)
Normal Depth of Field:
25 mm - 280 mm (1"- 11")
Reduced Depth of Field:
25 mm - 150 mm (1"- 6")
0.33 mm (13 mil) bar code
Omni Scan Scan Speed: No. of Scan Lines:
1333 scan lines per second 20
Single-Line Scan Speed: No. of Scan Lines:
67 scan lines per second 1
Motor Speed:
4000 RPM
Min Bar Width:
0.127 mm (5.0 mil)
Decode Capability:
All standard 1-D bar codes including RSS-14, RSS-Expanded, and RSS-14 Limited
System Interfaces:
RS232, Keyboard Wedge, Stand-Alone Keyboard, Light Pen Emulation, RS485, USB (low speed and full speed), OCIA
Print Contrast: No. Characters Read: Beeper Operation: Indicators (LED): Termination: Cable:
35% minimum reflectance difference Up to 80 data characters Maximum number will vary based on symbology and density. 7 tones or no beep Blue = laser on, ready to scan White = good read, decoding 10 position modular RJ45 connector Application Dependent
Mechanical Scanner Length:
189 mm (7.44")
Scanner Width:
65 mm (2.56")
Scanner Height:
73 mm (2.88")
Scanner Weight:
195 g (6.9 oz.)
Specifications subject to change without notice.
27
Page 32
DESIGN SPECIFICATIONS MS3780 Electrical Voltage Supply:
5VDC ± 0.25V
Operating Power:
1.375 W
Standby Power:
1.0 W
Operating Current:
275 mA typical at 5VDC
Standby Current:
200 mA typical at 5VDC
DC Transformers:
Class II; 5.2VDC @ 1A
For regulatory compliance information, see pages 41 - 43.
Environmental Operating Temperature:
-20°C to 40°C (-4°F to 104°F)
Storage Temperature:
-40°C to 60°C (-40°F to 140°F)
Humidity: Contaminants: Ventilation: Shock:
5% to 95% relative humidity, non-condensing Sealed to resist airborne particulate contaminants None required Withstands multiple drops from 1.5 meters
Specifications subject to change without notice.
28
Page 33
APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER
VERSION IDENTIFIER
MS3780
INTERFACE
9
OCIA and RS232 Transmit/Receive
11
RS485S and Full RS232
38
RS232 Low Speed USB*, Keyboard Emulation or USB Serial Emulation Mode
40
Full Speed USB
41
RS232/Light Pen Emulation
47
Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive
48
Stand Alone Keyboard and RS232 Transmit/Receive
120
USB and RS232 Transmit/Receive with EAS
®
S
Applicable for IBM Host applications.
The MS3780 scanner with Built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. Many RS232 configurable functions (e.g. formatting) available in other Metrologic scanners are also available as keyboard wedge functions. The following are the most important selectable options specific to the keyboard wedge. Keyboard Type • •
** AT (includes IBM® PS2 models 50, 55, 60, 80) IBM PS2 (includes models 30, 70, 8556)
Keyboard Country Type • • • • •
USA ** Belgium French German Hungarian
• • • • •
**
Default setting. For a complete list of default settings, see Default Settings Communication Parameters starting on page 30 of this guide. Refer to the MetroSelect® Configuration Guide (MLPN 00-02407) or MetroSet2’s help files for information on how to change the default settings.
Italian Japanese Russian Cyrillic Slovenian Spanish
• • • •
Swiss Swedish/Finnish Turkish United Kingdom
29
Page 34
DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is off or disabled. Every interface does not support every parameter. If the interface supports a parameter listed in the charts on the following pages, a check mark ( ) will appear in the column for that interface. PARAMETER
DEFAULT
UPC/EAN
*
Code 128
*
Code 93
*
Codabar
*
Interleaved 2 of 5 (ITF)
*
MOD 10 Check on ITF Code 11
*
Code 39 Full ASCII Code 39 MOD 43 Check on Code 39 MSI-Plessey MSI-Plessey 10/10 Check Digit MSI-Plessey MOD 10 Check Digit Paraf Support ITF Symbol Lengths
Variable
Minimum Symbol Length Symbol Length Lock
4 None
RSS14 Enable RSS14 ID “]e0”
*
RSS14 App ID “01”
*
RSS14 Check Digit
*
RSS Expanded Enable S
®
Applicable for IBM Host applications.
30
OCIA
USB
RS232*
LIGHT PEN
RS485S
KBW
Page 35
DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER
DEFAULT
OCIA
USB
RS232*
LIGHT PEN
RS485S
KBW
*
Expanded ID “]e0” RSS Limited Enable RSS Limited ID “]e0”
*
RSS Limited App ID “01”
*
RSS Limited Check Digit
*
Bars High as Code 39
*
Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS
*
DTS/NIXDORF NCR F NCR S Poll Light Pen Source Beeper Tone
Normal
Beep/Transmit Sequence
Before Transmit
Communication Timeout
None
Razzberry Tone on Timeout Three Beeps on Timeout No Beeps on Timeout
*
Enter Power Save Mode
5 mins.
Same Symbol Rescan Timeout: 500 msecs Programmable in 50 msec steps (MAX 6.35 seconds)
*
Intercharacter Delay Programmable in 1 msec steps (MAX 255 msecs) Number of Scan Buffers S
1 msecs 10 msecs in KBW 1
®
Applicable for IBM Host applications.
31
Page 36
DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER Transmit UPC-A Check Digit
DEFAULT
*
Transmit UPC-E Check Digit Expand UPC-E Convert UPC-A to EAN-13 Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 Transmit UPC-A Number System
*
Transmit UPC-A Manufacturer ID#
*
Transmit UPC-A Item ID#
*
Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop/Start Characters Transmit Mod 10/ITF Transmit MSI-Plessey Check Characters Parity
Space
Baud Rate
9600
8 Data Bits 7 Data Bits
*
Stop Bits
2
Transmit Sanyo ID Characters S
Applicable for IBM® Host applications.
32
OCIA
USB
RS232*
LIGHT PEN
RS485S
KBW
Page 37
DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER
DEFAULT
OCIA
USB
RS232*
LIGHT PEN
RS485S
KBW
Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Transmit AIM ID Characters STX Prefix ETX Suffix Carriage Return
*
Line Feed - disabled by default in KBW
*
Tab Prefix Tab Suffix “DE” Disable Command “FL” Laser Enable Command DTR Handshaking Support RTS/CTS Handshaking
*
Character RTS/CTS Message RTS/CTS XON/XOFF Handshaking ACK/NAK Two Digit Supplements as code 39
Five Digit Supplements as code 39
Bookland as code 39
977 (2 digit) Supplemental Requirement S
®
Applicable for IBM Host applications.
33
Page 38
DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER
DEFAULT
Supplements are not Required
*
Two Digit Redundancy
*
OCIA
USB
RS232*
LIGHT RS485S PEN
Five Digit Redundancy
100 msec to Find Supplement Configurable in 100msec steps (MAX 800 msec)
* as code 39
Coupon Code 128 Configurable Code Lengths
7 avail.
Configurable Prefix Characters
10 avail.
Configurable Suffix Characters
10 avail.
Prefixes for individual Code Types Editing Inter Scan-Code Delay Configurable (100 µsec steps)
800 µsec
Function/Control Key Support Minimum Element Width Configurable in 5.6 µsec steps
1 msec
*
Normal Depth of Field Reduced Depth of Field S
®
Applicable for IBM Host applications.
34
KBW
Page 39
UPGRADING THE FIRMWARE CONFIGURATION MODES The MS3780 Series scanner has three modes of configuration. •
Bar Codes The MS3780 can be configured by scanning the bar codes included in the Metrologic Single-Line Configuration Guide (MLPN 00-02544) or the Supplemental Configuration Guide (MLPN 00-02281). These manuals can be downloaded FREE of charge from Metrologic’s website (www.metrologic.com).
•
MetroSet2 This user-friendly Windows-based configuration program allows you to simply ‘point-and-click’ at the desired scanner options. This program can be downloaded FREE of charge from Metrologic’s website (www.metrologic.com) or set-up disks can be ordered by calling 1-800-ID-METRO.
•
Serial Configuration This mode of configuration is ideal for OEM applications. This mode gives the end-user the ability to send a series of commands using the serial port of the host system. The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Single-Line Configuration Guide (MLPN 00-02544).
35
Page 40
UPGRADING THE FIRMWARE The MS3780 Fusion is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and Metrologic's MetroSet2 software . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is also required to complete the upgrade. PowerLink Cable #54-54014 is required when using RS232 for the upgrade process. This cable can be ordered from Metrologic at 1-800-ID-METRO. Do not use the standard cable supplied with keyboard wedge or RS485 scanner interface kits. If using USB for the upgrade process, the standard USB Type A cable provided with the scanner can be used.
To upgrade the firmware in the MS3780: 1.
Plug the scanner into a serial communication port on the host system.
2.
Start the MetroSet2 software.
3.
Click on the plus sign (+) next to POS Scanners to expand the supported scanner list.
4.
Choose the Fusion from the list.
5.
Click on the Configure Fusion/3780 Scanner button.
6.
Choose Flash Utility from the options list located on the left side of the screen.
7.
Click on the Open File button in the Flash Utility window.
8.
Locate and open the flash upgrade file supplied by Metrologic.
9.
Select the COM port that the scanner is connected to on the host system.
10. Verify the settings listed in the Flash Utility window. 11. Click on the Flash Scanner button to begin the flash upgrade. 12. A message will appear on the screen when the upgrade is complete.
Metrologic's customer service department can be reached at 1-800-ID-METRO or 1-800-436-3876. MetroSet2 is available for download, at no additional cost, from http://www.metrologic.com/corporate/download.
36