The text of a manual · part 5 of 6
MS3780 Fusion Omni/Single Line Scanner Installation and User's Guide, pages 41 to 50
Pages 41 to 50 of 56
The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS3780
Page 41
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS3780 scanner interfaces terminate to a 10-pin modular socket. The serial number label indicates the interface enabled when the scanner is shipped from the factory.
Figure 24.
MS3780-47 Keyboard Wedge and Stand-Alone Keyboard Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 PC Data 5 PC Clock 6 KB Clock 7 PC +5V 8 KB Data 9 +5VDC 10 Shield Ground
Pin 1 2 3 4 5 6 7 8 9 10
MS3780-40 Full Speed USB Function Ground/USBRS232 Transmit Output RS232 Receive Input RTS Output CTS Input D+ USB +V D+5VDC Shield Ground
MS3780-41 RS232 and Light Pen Emulation Pin 1 2 3 4 5 6 7 8 9 10
Function Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input DTR Input/LTPN Source Reserved LTPN Data +5VDC Shield Ground
MS3780-38 RS232 Low Speed USB Pin Function 1 Ground/USB2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 D+ 7 USB +V 8 D9 +5VDC 10 Shield Ground
Continued on next page.
37
Page 42
SCANNER AND CABLE TERMINATIONS
Figure 25.
MS3780-9 OCIA
MS3780-11 RS485S Pin
Function
Pin
Function
1 2 3 4 5 6 7
Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input DTR Input IBM B-Transmit
1 2 3 4 5 6 7
8
IBM A+ Receive
8
9 10
+5VDC Shield Ground
9 10
Ground RS232 Transmit Output RS232 Receive Input RDATA RDATA Return Clock In Clock Out Clock in Return/ Clock out Rtrn +5VDC Shield Ground
MS3780-120 USB and RS232 with EAS Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 EAS 5 EAS + 6 USB D+ 7 USB +V 8 USB D9 +5VDC 10 Shield Ground S
Applicable for IBM® Host applications.
38
Page 43
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) RS232 PowerLink Cable 53-53000x-3 Pin
Function
1
Shield Ground
2
RS232 Transmit Output
3
RS232 Receive Input
4
DTR Input/Light Pen Source
5
Power/Signal Ground
6 7
Light Pen Data CTS Input
8
RTS Output
9
+5VDC
9
5
6
1
9-Pin D-Type Connector
USB Power/Communication Cable 53-53213x-N-3, 53-530214x-N-3 or 53-53235x-N-3 Pin Function 1 2
PC +5V/V_USB D-
3 4
D+ Ground
Shield Shield Stand Alone Keyboard PowerLink Cable 53-53020x-3 Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5VDC PC Power to KB 5 PC Clock 6 No Connect
USB Type A Locking with Power
USB Non-Locking
6-Pin Male Mini-DIN Connector
39
Page 44
SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 53-53002x-3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 PC Clock 6 No Connect
5-Pin DIN, Female
6-Pin DIN, Male
Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC. Keyboard Wedge Adapter Cable Pin PC Clock
2 3
PC Data No Connect
4
Power Ground
5
+5 Volts DC
Pin 1
40
Function
1
5-Pin DIN, Male
Function Keyboard Data
2
No Connect
3
Power Ground
4
+5 Volts DC
5
Keyboard Clock
6
No Connect
6-pin Mini DIN, Female
Page 45
REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1
Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2
Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard.
Atención La modificación de los procedimientos, o la utilización de controles o ajustes distintos de los especificados aquí, pueden provocar una luz de láser peligrosa. Bajo ninguna circunstancia el usuario deberá realizar el mantenimiento del láser del escáner. Ni intentar mirar al haz del láser incluso cuando este no esté operativo. Tampoco deberá abrir el escáner para examinar el aparato. El hacerlo puede conllevar una exposición peligrosa a la luz de láser. El uso de instrumentos ópticos con el equipo láser puede incrementar el riesgo para la vista.
Attention L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou le laser. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez à une rayonnement laser qú êst hazardous. L'emploi d'appareils optiques avec cet équipement laser augmente le risque d'endommagement de la vision.
Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät hineinzusehen. Wenn Sie dies tun, können Sie sich einer gefährlichen Laserstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung.
Attenzione L’utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale può provocare delle esposizioni a raggi laser rischiose. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa. L’uso di apparecchi ottici, equipaggiati con raggi laser, aumenta il rischio di danni alla vista.
41
Page 46
REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022
Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3 métres (9.8 pieds) de long en extension maximale: Folgendes trifft zu, wenn das Scannerkabel länger als 3 Meter ist: This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense. Any unauthorized changes or modifications to this equipment could void the user’s authority to operate this device. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Notice This Class A digital apparatus complies with Canadian ICES-003.
Remarque Cet appareil numérique de classe A est conforme à la norme canadienne NMB-003.
European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Funkstöreigenschaften nach EN55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen. In diesem Fall kann vom Betreiber verlangt werden, angemessene Massnahmen durchzuführen.
Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure. Attention Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la cause d’interférences radio. Dans ce cas l’utiliseteur peut être amené à predre les mesures adéquates.
42
Page 47
REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Class B Devices The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.8 pieds) de long en extension maximale: Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help Notice This Class B digital apparatus complies with Canadian ICES-003. Remarque Cet appareil numérique de classe B est conforme à la norme canadienne NMB-003.
43
Page 48
LIMITED WARRANTY The MS3780 Fusion® scanners are manufactured by Metrologic at its Suzhou,China facility. The MS3780 Fusion scanners have a three (3) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS3780 Fusion scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of product or refund of product price at the sole discretion of Metrologic. Faulty equipment must be returned to one of the following Metrologic repair facilities: Blackwood, New Jersey, USA; Madrid, Spain; or Suzhou, China. To do this, contact the appropriate Metrologic Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product which, in the sole judgment of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if: (i) the case of Product is opened by anyone other than Metrologic’s repair department or authorized repair centers; or (ii) any software is installed on the Product other than a software program approved by Metrologic. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN.
CORPORATE HEADQUARTERS, NORTH AMERICA
METROLOGIC EUROPEAN REPAIR CENTER (MERC)
Metrologic Instruments, Inc. 90 Coles Rd. Blackwood, NJ 08012-4683 Customer Service Department Tel: 1-800-ID-METRO Fax: 856-228-6673 Email: info@metrologic.com
Metrologic Eria Ibérica, SL C/Alfonso Gomez, 38-40, 1D 28037 Madrid Tel: +34 913 751 249 Fax: +34 913 270 437
MTLG AUTO ID INSTRUMENTS (SHANGHAI) CO., LTD Suzhou Sales Office BLK A, Room# 03/03-04 No.5 Xinghan Street, Xinsu Industrial Square China-Singapore Suahou Industrial Park, Suzhou, PRC Tel: 86-512-67622550 Fax: 86-512-67622560 Email: info@cn.metrologic.com
44
Page 49
PATENTS Patent Information This METROLOGIC product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Patent No.; 5,216,232; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,557,093; 5,591,953; 5,616,908; 5,627,359; 5,637,852; 5,661,292; 5,767,501; 5,777,315; 5,789,730; 5,789,731; 5,796,091; 5,811,780; 5,825,012; 5,828,048; 5,844,227; 5,883,375; 5,886,337; 5,895,907; 5,925,870; 5,925,871; 5,939,698; 5,942,743; 6,029,894; 6,098,885; 6,182,898; 6,189,793; 6,286,760; 6,299,067; 6,347,743; 6,412,696; 6,460,767; 6,604,684; 6,619,549; 6,856,572; 6,857,572; 6,905,071; 6,975,456; 6,209,789; 6,860,427; 6,863,217; 6,905,071; 6,976,632; 7,017,813; 7,021,547; 7,044,383; 7,097,105; 7,156,310; 7,252,238 No license right or sublicense is granted, either expressly or by implication, estoppel, or otherwise, under any METROLOGIC or third party intellectual property rights (whether or not such third party rights are licensed to METROLOGIC), including any third party patent listed above, except for an implied license only for the normal intended use of the specific equipment, circuits, and devices represented by or contained in the METROLOGIC products that are physically transferred to the user, and only to the extent of METROLOGIC’S license rights and subject to any conditions, covenants and restrictions therein. Other worldwide patents pending.
45
Page 50
INDEX A
E
AC ....................................... 2, 7–11 Accessories ...............................2, 3 Adapter..........................................9 Audible Indicator.. 15–17, 23–26, 36
EAS............................................. 12 EMC............................................ 42 EMI ............................................. 42 Emissions.................................... 42
B
F
Bar Code ....... 15–17, 23–26, 27, 35 Bar Width.....................................27 Beep .............. 15, 16, 17, 23–26, 36 Blue LED ................... 15–17, 23–26 Button ................................4, 13–14 CodeGate ..................................4 Mode Select...............................4
Failure Modes...................................... 17 Firmware ..................................... 36 Flash ROM.................................... 1
C
I
Cable Communication... 2, 7–11, 23–26, 39–40 EAS..........................................12 Keyboard Wedge ........... 2, 39–40 OCIA ..........................................2 Pin Assignments ................39–40 PowerLink .. 2, 6, 7–11, 36, 39–40 RS232........................................2 RS485........................................2 Troubleshooting .................23–26 USB ...................................39–40 Caution .......................... 5, 7–11, 41 Class ...........................................43 CodeGate ...................... 1, 4, 13–14 Communication ......... 16, 23–26, 29 Parameters ........................30–34 Compliance ................. 7–11, 41, 42 Components ..............................2, 4 Configuration ............. 15, 17, 35, 36 Default ...............................30–34 Current ........................................28
Immunity ..................................... 42 Indicator Audible .. 4, 15–17, 23–26, 27, 36 Failure ..................................... 17 Visual .... 4, 15–17, 23–26, 27, 36 Interface ...................................... 27 Keyboard Wedge. 1, 9, 26, 30–34 Laser Emulation ............ 1, 30–34 Light Pen ................... 1, 7, 30–34 OCIA ......................... 1, 8, 30–34 RS232 ........... 1, 7, 25, 26, 30–34 RS485 ....................... 1, 8, 30–34 Stand-Alone Keyboard ........ 1, 10 Troubleshooting................. 23–26 USB ......................... 1, 11, 30–34 IR Activation Range .................... 22
D
Label Caution ...................................... 5 Serial Number ........................... 5 Laser ....................................... 4, 41 Laser Emulation .................... 30–34
DC ...........................................2, 28 Default Settings ......... 13, 29, 30–34 Depth of Field Normal ................... 18, 20, 27, 34 Reduced .......... 19, 20, 21, 27, 34
46
H Host ...................................... 23–26