Page 21

SCANNER OPERATION Failure Mode Indicators Both Blue LEDs Flashing with One Emitted Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure. Return the unit to a Metrologic authorized service center for repair.

Both Blue LEDs and the White LED are Flashing with Two Emitted Razzberry Tones This indicates that the scanner has experienced a motor failure. Return the unit to a Metrologic authorized service center for repair.

Continuous Razzberry Tone with Both LEDs Off - On Power Up A continuous razzberry tone upon power up indicates there has been an electronic failure. Return the unit to a Metrologic authorized service center for repair.

Three Beeps - On Power Up This indicates that the nonvolatile memory that holds the scanner configuration has failed. Return the unit to a Metrologic authorized service center for repair.

17

Page 22

SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code.

Figure 19. Normal Depth of Field

* All specifications are subject to change without notice.

18

Page 23

SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code.

Figure 20. Reduced Depth of Field

* All specifications are subject to change without notice.

19

Page 24

SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone

MINIMUM BAR CODE ELEMENT WIDTH A

B

C

D

E

F mm

.13

.15

.19

.25

.33

.66 mils

5.2

5.7

7.5

10

13

26

Figure 21. Normal Scan Zone by Bar Code Element Width

* All specifications are subject to change without notice.

20

Page 25

SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone

MINIMUM BAR CODE ELEMENT WIDTH A

B

C

D

E

F mm

.13

.15

.19

.25

.33

.66 mils

5.2

5.7

7.5

10

13

26

Figure 22. Reduced Scan Zone by Bar Code Element Width

* All specifications are subject to change without notice.

21

Page 26

SCANNER OPERATION IR Activation Range* Fusion’s default power save mode† is Laser Off then Motor Off Delayed. This power save mode turns the laser off after five minutes of non-use. The motor will turn off after twenty-five minutes of non-use. Any movement detected by the IR in the activation area will cause the scanner to exit power save mode. The laser and motor will automatically turn back on preparing the scanner for bar code recognition, decoding and transmission.

Figure 23. Normal IR Activation Range

* All specifications are subject to change without notice. † Refer to the MetroSelect Configuration Guide (MLPN 00-02407) for additional information on configurable power save modes.

22

Page 27

TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 44.

Symptoms

Possible Cause(s)

Solution

All Interfaces The unit has no LEDs, beeper or motor spin.

No power is being supplied to the scanner.

Check the transformer, outlet and power strip. Make sure the cable is plugged into the scanner.

The unit has no LEDs and / or beeper.

No power is being supplied to the scanner from host.

Some host systems cannot supply enough current to power the MS3780. Use the power supply included with the scanner.

There are multiple scans upon presentation of code.

The same symbol timeout is set too short.

Adjust the same symbol timeout for a longer time increment.

The beeper is disabled.

Enable the beeper.

No tone is selected.

Select a tone.

The unit is trying to scan a particular symbology that is not enabled.

UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected

The unit powers up but does not beep.

The unit powers up but does not scan and/or beep.

The scanner has been configured for a character length lock, or a minimum length and bar code being scanned does not satisfy the configured criteria.

Verify that the bar code that is being scanned falls into the criteria. Typical of Non-UPC/EAN codes. The scanner defaults to a minimum of 4 character bar code.

23

Page 28

TROUBLESHOOTING GUIDE Symptoms

Possible Cause(s)

Solution

The unit scans a bar code, but locks up after the first scan (the white LED stays on).

The scanner is configured to support some form of host handshaking but is not receiving the signal.

If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.

The unit scans but the data transmitted to the host is incorrect.

The scanner’s data format does not match the host system requirements.

Verify that the scanner’s data format matches the format required by the host. Make sure that the scanner is connected to the proper host port.

The bar code may have been printed incorrectly.

Check if it is a check digit, character or border problem.

The scanner is not configured correctly for the type of bar code.

Check if check digits are set properly.

The minimum symbol length setting does not work with the bar code.

Check if the correct minimum symbol length is set.

All Interfaces

Scanner beeps at some bar codes and NOT for others of the same bar code symbology.

24

Page 29

TROUBLESHOOTING GUIDE Symptoms

Possible Cause(s)

Solution

All Interfaces During power up the unit beeps 3 times.

There is a non-volatile RAM failure.

Contact a Metrologic service representative.

During power up the unit razzes continuously.

There has been a diagnostic failure.

Contact a Metrologic service representative.

During power up the unit razzes once and the blue LED flashes.

There is a VLD failure.

Contact a Metrologic service representative.

During power up the unit razzes twice and both LEDs flash.

There is a scanner motor failure.

Contact a Metrologic service representative.

RS232 Only

The unit powers up OK and scans OK but does not communicate properly to the host.

The com port at the host is not working or is not configured properly. The cable is not connected to the proper com port.

Check to make sure that the baud rate and parity of the scanner and the communication port match and that the program is looking for RS232 data.

The com port is not operating properly.

25

Page 30

TROUBLESHOOTING GUIDE Symptoms

Possible Cause(s)

Solution

RS232 Only The host is The scanner and host receiving data may not be configured but the data does for the same interface. not look correct. Characters are being dropped.

The intercharacter delay needs to be added to the transmitted output.

Check that the scanner and the host are configured for the same interface. Add some intercharacter delay to the transmitted output by using the MetroSelect Configuration Guide (MLPN 00-02407).

Keyboard Wedge Only The unit scans the bar code but there is no data.

The unit scans but the data is not correct.

The unit may not be configured correctly.

The unit may not be configured correctly.

Make sure the scanner is configured for the appropriate mode. Make sure that the proper PC type (ie. AT, PS2 or XT) is selected. Verify correct country code and data formatting are selected. Adjust the intercharacter delay.

The unit is not transmitting each character.

The unit may not be configured correctly.

Increase the interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try both settings.

Alpha characters The computer is in show as lower caps lock mode. case.

Enable caps lock detect setting of the scanner to detect whether the PC is operating in caps lock.

Everything works except for a couple of characters.

Try operating the scanner in Alt Mode.

26

These characters may not be supported by the current country’s key look up table.