Page 11

INSTALLATION RS232 or Light Pen 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS3780.

3.

Connect the 9-pin female end of the PowerLink cable to the appropriate communication port on the host device.

4.

Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.

5.

Connect AC power to the transformer.

6.

Turn on the host device.

Figure 7.

When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will emit one beep. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur. See Caution statement on page 5.

7

Page 12

INSTALLATION RS485S or OCIA 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS3780.

3.

For RS485: Connect the other end of the MVC cable to Port 9 of the host device. For OCIA: Connect the other end of the MVC cable to the appropriate communication port on the host device.

4.

Figure 8. RS485 (above), OCIA (below)

Turn on the host device.

When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will emit one beep. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur. See Caution statement on page 5. S

8

®

Applicable for IBM Host applications.

Page 13

INSTALLATION Keyboard Wedge 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS3780.

3.

Disconnect the keyboard from the host device.

4.

Connect the “Y” end of the PowerLink cable to the keyboard and the keyboard port on the host PC. If necessary use the male/female adapter cable supplied with the scanner for proper connections.

5.

Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.

6.

Connect AC power to the transformer.

7.

Turn on the host device.

Figure 9.

When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will emit one beep. Powering the MS3780 directly from the host device can sometimes cause interference with the operation of the scanner or the computer. Not all computers supply the same current through the keyboard port. For this reason, Metrologic recommends using an external power supply. For additional information contact a Metrologic customer service representative.

See Caution statement on page 5.

9

Page 14

INSTALLATION Stand-Alone Keyboard 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS3780.

3.

Connect the other end of the PowerLink cable to the keyboard port on the host device.

4.

Plug the external power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.

5.

Connect AC power to the transformer.

6.

Turn on the host device.

Figure 10.

When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will emit one beep.

Powering the MS3780 directly from the host device can sometimes cause interference with the operation of the scanner or the computer. Not all computers supply the same current through the keyboard port. For this reason, Metrologic recommends using an external power supply. For additional information contact a Metrologic customer service representative.

See Caution statement on page 5.

10

Page 15

INSTALLATION Full Speed or Low Speed USB (Integrated) 1.

Turn off the host device.

2.

Plug the male 10-pin RJ45 end of the USB PowerLink cable into the 10-pin socket on the MS3780.

3.

Plug the other end of the USB interface cable into the host device’s USB port.

4.

Turn on the host device.

Figure 11.

As a default, the MS3780-38 leaves the factory with USB Keyboard Emulation Mode enabled. For information on configuring the MS3780-38 for USB Serial Emulation Mode, please refer to the USB: Low Speed section of the MetroSelect Configuration Guide (MLPN 00-02407).

When the scanner first receives power the white LED will flash, one blue LED will turn on and the scanner will emit one beep.

Plugging the scanner into the USB port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.

See Caution statement on page 5.

11

Page 16

INSTALLATION EAS Deactivation SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is a list of Checkpoint recommended switch bank settings. Checkpoint Recommended Switch Bank Settings For RS232 and IBM SW1 SW2 Switch 1 and 6

ON

Switch 1 and 6

ON

Switch 2, 3, 4, and 5

OFF

Switch 2, 3, 4, and 5

OFF

Checkpoint Recommended Switch Bank Settings For USB SW1

SW2

Switch 1

ON

Switch 1

ON

Switch 2, 3, 4, 5, and 6

OFF

Switch 2, 3, 4, 5, and 6

OFF

All Fusion models equipped with EAS capabilities have an EAS designation in their model numbers. The cable supplied with these units will have additional wires for connection to the Checkpoint Device.

Figure 12. EAS Cable

Figure 13 shows the location of the EAS deactivation area for Fusion. It is important to pass the entire tag through this area to deactivate the security tag.

Figure 13. EAS Deactivation Area

12

Page 17

SCANNER OPERATION The Scan Pattern Mode Select Button There are two configurable scan pattern modes available with the MS3780. •

The primary scan pattern mode is the default scan pattern active when the scanner starts. By default, the primary scan pattern is set to all-scan-lines for omnidirectional reading.

•

Pressing the scan pattern mode button (see figure below) activates the secondary scan pattern mode. By default, the secondary scan pattern is set to single-line mode for menu reading. Please refer to the MetroSelect Configuration Guide for information on changing the default scan pattern settings.

To Change Scan Pattern Modes 1.

To activate the secondary scan pattern, press and release the mode select button. Press and Release the Mode Select Button

Pattern Mode LED Switches to New Active Pattern

Figure 14.

Figure 15.

Activating a pattern mode when the scanner is out of its stand does not change the in-stand pattern mode. When the scanner is returned to the stand it will automatically revert to the most recent scan pattern selected during in-stand operation. 2.

To re-activate the primary scan pattern, press and release the mode select button again.

13

Page 18

SCANNER OPERATION How to Use CodeGate and the Manual Activation Mode For illustration purposes the unit’s scan pattern has been set to single-line (menu reading) mode.

CODEGATE

MANUAL ACTIVATION MODE*

*

Figure 16.

Factory Defaults:

This feature is not a default setting. Refer to the MetroSelect Configuration Guide for instructions on enabling the Manual Activation Mode.

Figure 17.

In-Stand, CodeGate is not active (Amber LED is On) Out-of-Stand, CodeGate is active (Amber LED is Off)

For information on how to change the factory defaults, refer to the MetroSelect Configuration Guide (00-02407).

14

Page 19

SCANNER OPERATION Audible Indicators When the MS3780 is in operation, it can provide audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). For instruction on how to change the tone of the beeper, refer to the MetroSelect Configuration Guide (00-02407).

One Beep When the scanner first receives power; the white LED will flash, one blue LED will turn on and the scanner will emit a beep (the white LED will remain on for the duration of the beep). The scanner is now ready to scan. When the scanner successfully reads a bar code, the white LED will flash and the scanner will emit one beep (if configured to do so). If the scanner does not emit one beep and the white light does not flash, then the bar code has not been successfully read.

Razzberry Tone This is a failure indicator. Refer to Failure Mode Indicators on page 17.

Three Beeps - during operation When placing the scanner in configuration mode, the white and blue LEDs will flash while the scanner emits three beeps. The white and blue LEDs will continue to flash until the unit exits the configuration mode. Upon exiting the configuration mode, the scanner will emit three beeps and the white LED will stop flashing. When configured, three beeps can also indicate a communications timeout during normal scanning mode. When using one-code-programming, the scanner will emit three beeps: the current selected tone, followed by a short pause then a high tone and a low tone. This tells the user that the single code configuration has successfully configured the scanner.

Three Beeps - on power up This is a failure indicator. Refer to Failure Mode Indicators on page 17.

15

Page 20

SCANNER OPERATION Visual Indicators There are four LEDs located on the top of the MS3780. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner.

Figure 18. LED Indicators

No LEDs The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. They are also not illuminated when all lasers are turned off for any reason. Steady Blue Single-Line LED Indicates the laser is active and the scanner is in Single-Line Mode. The blue LED will remain illuminated until the laser is deactivated. Steady Blue Omni LED Indicates the laser is active and the scanner is in the Omnidirectionsl Mode. The blue LED will remain illuminated until the laser is deactivated. Steady Blue Single-Line or Omni LED and a Single White LED Flash When the scanner successfully reads a bar code, the white LED will flash and the scanner will beep once. If the white LED does not flash or the scanner does not beep, then the bar code has not been successfully read. Steady White and Blue Single-Line or Omni LED After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s white LED will remain on until the data can be transmitted. Alternate Flashing of Both Blue LEDs and the White LED This indicates the scanner is in program mode. A razzberry tone indicates that an invalid bar code has been scanned in this mode. Steady Amber LED Indicates that CodeGate is not active (in-stand default). 16