The text of a manual · part 1 of 6

MS3780 Fusion Omni/Single Line Scanner Installation and User's Guide, pages 1 to 10

Pages 1 to 10 of 56: MS3780 Fusion®; Manual Date Code

The original document is the PDF (3.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MS3780

Page 1 read from a scan by OCR; it may hold reading errors

Metrologic

We really work for you.™

METROLOGIC INSTRUMENTS, INC.

MS3780 Fusion® Omni/Single Line Scanner Installation and User’s Guide

Page 2

Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc. or their respective companies.

Page 3

TABLE OF CONTENTS Introduction Product Overview ............................................................................................. 1 Scanner and Accessories................................................................................. 2 Scanner Components....................................................................................... 4 Caution and Serial Number Labels................................................................... 5 Stand Specifications ......................................................................................... 5 Cable Removal................................................................................................. 6 Cable Connection Warning............................................................................... 6 Maintenance..................................................................................................... 6 Installation RS232 or Light Pen .......................................................................................... 7 RS485 or OCIA ................................................................................................ 8 Keyboard Wedge.............................................................................................. 9 Stand-Alone Keyboard Wedge ....................................................................... 10 Full Speed or Low Speed USB (Integrated) ................................................... 11 EAS Deactivation ........................................................................................... 12 Scanner Operation The Scan Pattern Mode Select Button ........................................................... 13 How to Use CodeGate and the Manual Activation Mode ............................... 14 Indicators Audible ....................................................................................................... 15 Visual ......................................................................................................... 16 Failure ........................................................................................................ 17 Depth of Field Specifications Normal Scan Zone ..................................................................................... 18 Reduced Scan Zone................................................................................... 19 Depth of Field by Bar Code Element Width Normal Scan Zone ..................................................................................... 20 Reduced Scan Zone................................................................................... 21 IR Activation Range........................................................................................ 22 ii

Page 4

TABLE OF CONTENTS Troubleshooting Guide ....................................................................................... 23 Design Specifications ......................................................................................... 27 Applications and Protocols ................................................................................. 29 Default Settings - Communication Parameters................................................... 30 Configuration Modes ...................................................................................... 35 Bar Codes .................................................................................................. 35 MetroSet2................................................................................................... 35 Serial Configuration .................................................................................... 35 Upgrading the Firmware ................................................................................. 36 Scanner and Cable Terminations ....................................................................... 37 Regulatory Compliance ...................................................................................... 41 Limited Warranty ................................................................................................ 44 Patents ............................................................................................................... 45 Index .................................................................................................................. 46 Contact Information and Office Locations........................................................... 48 iii

Page 5

INTRODUCTION ® The MS3780 Fusion is a hand-held, omnidirectional bar code scanner with optional single-line scanning capabilities. It utilizes the powerful Metrologic QuantumE® scan engine to provide an outstanding scan performance on all standard 1D bar code symbologies, including RSS. Designed for retail applications, the Fusion includes additional key product features like:

• • • • • • • • • • • •

Fully Automatic Scanning Operation Single-Line Mode for Menu Reading Custom Configurable Scan Pattern User-Replaceable Single-Cable Interface to Host (PowerLink Compatible) User Configurable Depth of Field Easy Bar Code Configuration Data Editing 7 Beeper Tones Firmware updates are easily loaded into Flash memory OPOS and JPOS System Compatible CodeGate® Sunrise 2005 Compliant

SCANNER

INTERFACE

MS3780-9

OCIA and RS232 Transmit/Receive

MS3780-11

RS485S and Full RS232

MS3780-38

RS232 Low Speed USB*, Keyboard Emulation Mode or USB Serial Emulation Mode

MS3780-40

Full Speed USB

MS3780-41

RS232/Light Pen Emulation

MS3780-47

Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive

MS3780-48

Stand Alone Keyboard and RS232 Transmit/Receive

MS3780-120

USB and RS232 Transmit/Receive with EAS

* Configurable for Keyboard Emulation Mode or Serial Emulation Mode. The default setting is Keyboard Emulation Mode. S

®

Applicable for IBM Host applications.

1

Page 6

INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No.

Description

MS3780

Fusion Scanner

00-02099

MS3780 Installation and User’s Guide *

00-02407

MetroSelect® Configuration Guide *

* Guides also available for download at www.metrologic.com.

OPTIONAL ACCESSORIES Part No.

Description

AC to DC Power Transformer - Regulated 5.2VDC @ 1A output. 46-00525

90VAC – 255VAC United States, Canada and Japan

46-00526

90VAC – 255VAC Continental European

46-00527

90VAC – 255VAC United Kingdom

46-00528

90VAC – 255VAC Australia

46-00529

90VAC – 255VAC China

46-00530

90VAC – 255VAC India

The following cables are for Fusion models not equipped with EAS.

53-53000x-3

RS232 PowerLink Cable with Built in Power Jack coiled cord, long strain relief, black

53-53002x-3

Keyboard Wedge PowerLink cable with Adapter Cable coiled cord, long strain relief, black

53-53020x-3

Stand Alone Keyboard PowerLink Cable coiled cord, long strain relief, black

MVC-3MPC-IB9

Metrologic Voltage Converter Cable, ±12VDC to +5.2VDC For IBM Applications

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s customer service department at 1-800-436-3876.

2

Page 7

INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No.

Description

MVC-3MNC-N7052

Metrologic Voltage Converter Cable, ±12VDC to +5.2VDC For OCIA Applications

53-53213x-N-3

USB Full Speed Cable, Locking Plus-Power™Type A straight cord, short strain relief USB Full Speed Cable, Locking Plus-Power™Type A straight cord, short strain relief

53-53214x-N-3 This cable is for use with full speed USB (-40) interface only. USB Low Speed Communication Cable, Type A (Non-Locking) Connector straight cord, short strain relief

53-53235x-N-3

The following cables are for Fusion models equipped with EAS.

59-59000x-E-3

RS232 PowerLink Cable with Built in Power Jack and EAS Connection Wire long strain relief, straight cable, black

59-59006x-E-3

RS485S PowerLink Cable with Built in Power Jack and EAS Connection Wire long strain relief, straight cable, black

55-55809x-N-E-3

USB, Keyed, Type A, EAS Connection Wire Long strain relief, straight cable, black

46-00225

Stand

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s customer service department at 1-800-436-3876. S

®

Applicable for IBM Host applications.

3

Page 8

INTRODUCTION Scanner Components

Figure 1. Scanner Components

ITEM NO.

4

DESCRIPTION

1

Red Output Window, Laser Aperture (See page 41)

2

Mode Select Button (See page 13)

3

Beeper (See page 15)

4

Blue LED, Single-Line Mode / Menu Reading (See page 15)

5

White LED (See page 15)

6

Blue LED, All Scan Lines On / Omnidirectional Reading (See page 15)

7

Amber LED, CodeGate (See page 15)

8

CodeGate Button (See page 14)

9

Pin Hole for Cable Release (See page 6)

10

10-Pin RJ45, Female Socket (See page 37)

Page 9

INTRODUCTION Caution and Serial Number Labels

Figure 2. Caution and Serial Labels Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source.

Stand Specifications

Figure 3. Stand Specifications

5

Page 10

INTRODUCTION Maintenance Smudges and dirt on the unit's window can interfere with the unit's performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, nonabrasive cleaning cloth then gently wipe the window clean. If the unit's case requires cleaning, use a mild cleaning agent that does not contain strong oxidizing chemicals. Strong cleaning agents may discolor or damage the unit's exterior.

Cable Removal Disconnect the power supply from the PowerLink cable and turn off power to the host system before removing the cable from the scanner. 1.

2. 3.

4.

Locate the small ‘pin-hole’ beneath the Fusion logo on the front side of the scanner near the end of the handle. Bend an ordinary paperclip into the shape shown in figure 4. Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’. There will be a faint ‘click’ when the connector’s lock releases. Pull gently on the cable’s strain-relief to remove the cable.

Figure 4.

Cable Connection Warning Important: If the PowerLink cable is not fully latched the unit can power intermittently.

Figure 5.

6

Figure 6.