The text of a manual · part 4 of 6
MS3580 QuantumT Installation and User's Guide, pages 31 to 40
Pages 31 to 40 of 60
The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS3580
Page 31
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 46.
Symptoms
Possible Cause(s)
Solution
All Interfaces The unit has no LEDs, beeper or motor spin.
No power is being supplied to the scanner.
Check the transformer, outlet and power strip. Make sure the cable is plugged into the scanner.
The unit has no LEDs and / or beeper.
No power is being supplied to the scanner from host.
Some host systems cannot supply enough current to power the MS3580. Use the power supply included with the scanner.
There are multiple scans upon presentation of code.
The same symbol timeout is set too short.
Adjust the same symbol timeout for a longer time increment.
The beeper is disabled.
Enable the beeper.
No tone is selected.
Select a tone.
The unit is trying to scan a particular symbology that is not enabled.
UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected
The unit powers up but does not beep.
The unit powers up but does not scan and/or beep.
The scanner has been configured for a character length lock, or a minimum length and bar code being scanned does not satisfy the configured criteria.
Verify that the bar code that is being scanned falls into the criteria. Typical of Non-UPC/EAN codes. The scanner defaults to a minimum of 4 character bar code.
27
Page 32
TROUBLESHOOTING GUIDE Symptoms
Possible Cause(s)
Solution
The unit scans a bar code, but locks up after the first scan (the white LED stays on).
The scanner is configured to support some form of host handshaking but is not receiving the signal.
If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.
The unit scans but the data transmitted to the host is incorrect.
The scanner’s data format does not match the host system requirements.
Verify that the scanner’s data format matches the format required by the host. Make sure that the scanner is connected to the proper host port.
All Interfaces
Scanner beeps at some bar codes and NOT for others of the same bar code symbology.
28
The print quality of the bar code is suspect.
The type of printer and/or the printer settings could be the problem.
The aspect ratio of the bar code is out of tolerance.
Check the print mode or change the printer settings. For example, change to econo mode or high speed.
The bar code may have been printed incorrectly.
Check if it is a check digit, character or border problem.
The scanner is not configured correctly for the type of bar code.
Check if check digits are set properly.
The minimum symbol length setting does not work with the bar code.
Check if the correct minimum symbol length is set.
Page 33
TROUBLESHOOTING GUIDE Symptoms
Possible Cause(s)
Solution
All Interfaces During power up the unit beeps 3 times.
There is a non-volatile RAM failure.
Contact a Metrologic service representative.
During power up the unit razzes continuously.
There is a RAM or ROM failure.
Contact a Metrologic service representative.
During power up the unit razzes once and the blue LED flashes.
There is a VLD failure.
Contact a Metrologic service representative.
During power up the unit razzes twice and both LEDs flash.
There is a scanner motor failure.
Contact a Metrologic service representative.
RS232 Only
The unit powers up OK and scans OK but does not communicate properly to the host.
The com port at the host is not working or is not configured properly. The cable is not connected to the proper com port.
Check to make sure that the baud rate and parity of the scanner and the communication port match and that the program is looking for RS232 data.
The com port is not operating properly.
29
Page 34
TROUBLESHOOTING GUIDE Symptoms
Possible Cause(s)
Solution
RS232 Only The host is The scanner and host receiving data may not be configured but the data does for the same interface. not look correct. Characters are being dropped.
The intercharacter delay needs to be added to the transmitted output.
Check that the scanner and the host are configured for the same interface. Add some intercharacter delay to the transmitted output by using the MetroSelect Configuration Guide (MLPN 00-02407).
Keyboard Wedge Only The unit scans the bar code but there is no data.
The unit scans but the data is not correct.
The unit may not be configured correctly.
The unit may not be configured correctly.
Make sure the scanner is configured for the appropriate mode. Make sure that the proper PC type (ie. AT, PS2 or XT) is selected. Verify correct country code and data formatting are selected. Adjust the intercharacter delay.
The unit is not transmitting each character.
The unit may not be configured correctly.
Increase the interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try both settings.
Alpha characters The computer is in show as lower caps lock mode. case.
Enable caps lock detect setting of the scanner to detect whether the PC is operating in caps lock.
Everything works except for a couple of characters.
Try operating the scanner in Alt Mode.
30
These characters may not be supported by the current country’s key look up table.
Page 35
DESIGN SPECIFICATIONS MS3580 Operational Light Source: Laser Power:
Visible Laser Diode (VLD) @ 650 nm 1.1 mW
Normal Depth of Field:
19 mm - 273 mm (.75"- 10.75")
Reduced Depth of Field:
19 mm - 146 mm (.75"- 5.75")
0.33 mm (13 mil) bar code
Omni Scan Scan Speed: No. of Scan Lines:
1650 scan lines per second 20
Single-Line Scan Speed: No. of Scan Lines:
80 scan lines per second 1
Raster Scan Speed: No. of Scan Lines:
320 scan lines per second 4
Motor Speed:
5000 RPM
Min Bar Width:
0.127 mm (5.0 mil)
Decode Capability:
All standard 1-D bar codes including RSS-14, RSS-Expanded, and RSS-14 Limited
System Interfaces:
RS232, Keyboard Wedge, Stand-Alone Keyboard, Light Pen Emulation, IBM468x/469x, USB (low speed and full speed), Laser Emulation, RS232 TTL, OCIA
Print Contrast: No. Characters Read: Beeper Operation: Indicators (LED):
35% minimum reflectance difference Up to 80 data characters Maximum number will vary based on symbology and density. 7 tones or no beep Blue = laser on, ready to scan White = good read, decoding
Specifications subject to change without notice.
31
Page 36
DESIGN SPECIFICATIONS MS3580 Mechanical Width:
63 mm (2.48")
Depth:
50 mm (1.97")
Height:
68 mm (2.68")
Weight:
6 oz (170 g)
Electrical Voltage Supply:
5VDC ± 0.25V
Operating Power:
1.375 W
Standby Power:
1.0 W
Operating Current:
275 mA typical at 5VDC
Standby Current:
230 mA typical at 5VDC
DC Transformers:
Class II; 5.2VDC @ 1 A
For regulatory compliance information, see pages 44 - 46
Environmental Operating Temperature:
-20°C to 40°C (-4°F to 104°F)
Storage Temperature:
-40°C to 60°C (-40°F to 140°F)
Humidity: Contaminants: Ventilation:
5% to 95% relative humidity, non-condensing Sealed to resist airborne particulate contaminants None required
Specifications subject to change without notice.
32
Page 37
APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER
VERSION IDENTIFIER
MS3580
COMMUNICATION PROTOCOL(S)
9
OCIA and RS232 Transmit/Receive
11
IBM 46XX and Full RS232C
38
RS232 Low Speed USB, Keyboard Emulation or Serial Emulation
40
Full-Speed USB
41
Full RS232C/Light Pen Emulation
47
Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive
104
RS232, Transistor - Transistor Logic (TTL), Laser Emulation
The MS3580 scanner with built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. Many RS232 configurable functions (e.g. formatting) available in other Metrologic scanners are also available as keyboard wedge functions. The following are the most important selectable options specific to the keyboard wedge. Keyboard Type • • •
** AT (includes IBM® PS2 models 50, 55, 60, 80) XT IBM PS2 (includes models 30, 70, 8556)
Keyboard Country Type • • •
USA ** Belgium French
• • •
**
Default setting. For a complete list of default settings, see Default Settings Communication Parameters starting on page 34 of this guide. Refer to the MetroSelect® Configuration Guide (MLPN 00-02407) or MetroSet2’s help files for information on how to change the default settings.
German Italian Japan
• • •
Spanish Swiss United Kingdom
33
Page 38
DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled. Every interface does not support every parameter. If the interface supports a parameter listed in the charts on the following pages, a check mark ( ) will appear. RS232* PARAMETER
DEFAULT
UPC/EAN
*
Code 128
*
Code 93
*
Codabar
*
Interleaved 2 of 5 (ITF)
*
MOD 10 Check on ITF Code 11 Code 39
*
Full ASCII Code 39 MOD 43 Check on Code 39 MSI-Plessey MSI-Plessey 10/10 Check Digit MSI-Plessey MOD 10 Check Digit Paraf Support ITF Symbol Lengths Minimum Symbol Length Symbol Length Lock
Variable 4 None
RSS14 Enable RSS14 ID “]e0”
*
RSS14 App ID “01”
*
RSS14 Check Digit
*
RSS Expanded Enable
34
OCIA USB
OR
RS232 TTL
LIGHT IBM PEN 46XX
KBW
LASER EMULATION
Page 39
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER Expanded ID “]e0”
DEFAULT
OCIA USB
OR
RS232 TTL
LIGHT IBM PEN 46XX
KBW
LASER EMULATION
*
RSS Limited Enable RSS Limited ID “]e0”
*
RSS Limited App ID “01”
*
RSS Limited Check Digit
*
Bars High as Code 39
*
Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS DTS/NIXDORF
*
NCR F NCR S Poll Light Pen Source Beeper Tone
Normal
Beep/Transmit Sequence
Before Transmit
Communication Timeout
None
Razzberry Tone on Timeout Three Beeps on Timeout No Beeps on Timeout
*
Enter Power Save Mode
5 mins.
Same Symbol Rescan Timeout: 500 msecs Configurable in 50 msec steps (MAX 6.35 seconds)
*
Intercharacter Delay Configurable in 1 msec steps (MAX 255 msecs)
1 msecs 10 msecs in KBW
Number of Scan Buffers
1
35
Page 40
DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER Transmit UPC-A Check Digit
DEFAULT
*
Transmit UPC-E Check Digit Expand UPC-E Convert UPC-A to EAN-13 Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 Transmit UPC-A Number System
*
Transmit UPC-A Manufacturer ID#
*
Transmit UPC-A Item ID#
*
Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop/Start Characters Transmit Mod 10/ITF Transmit MSI-Plessey Check Characters Parity
Space
Baud Rate
9600
8 Data Bits 7 Data Bits
*
Stop Bits
2
Transmit Sanyo ID Characters
36
OCIA USB
OR
RS232 TTL
LIGHT IBM KBW PEN 46XX
LASER EMULATION