Page 21

SCANNER OPERATION Configurable Button Functions

5.

To scan and transmit additional bar codes, repeat steps 2 through 4.

6.

The primary scan pattern will automatically reactivate after the button is released and no bar code is present in the scan field.

17

Page 22

SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the unit’s* primary scan pattern has been set to all scan lines (omnidirectional reading) and the secondary pattern has been set to single-line (menu reading) with a 5 second button click timeout configured.

18

1.

The primary scan pattern is active when the scanner starts.

2.

To activate the secondary scan pattern, press and hold the button.

3.

To scan and transmit the bar code, align the laser line over the bar code while continuing to hold down the button. The scanner will beep once to indicate the bar code has been scanned and transmitted.

4.

The primary scan pattern will automatically reactivate after the button is released and no bar code is present in the scan field.

Page 23

SCANNER OPERATION Audible Indicators When the MS3580 is in operation, it provides audible feedback to indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). For instructions on how to change the tone of the beeper, refer to the MetroSelect Configuration Guide (00-02407).

One Beep When the scanner first receives power the white LED will flash, the blue LED will turn on and the scanner will beep once (the white LED will remain on for the duration of the beep). The scanner is now ready to scan. When the scanner successfully reads a bar code, the white LED will flash and the scanner will emit a beep (if configured to do so). If the scanner does not beep once and the white light does not flash, then the bar code has not been successfully read.

Razzberry Tone This is a failure indicator. Refer to Failure Mode Indicators on page 21.

Three Beeps - during operation When placing the scanner in configuration mode, the white LED will flash while the scanner simultaneously beeps three times. The white and blue LEDs will continue to flash until the unit exits configuration mode. Upon exiting configuration mode, the scanner will beep three times and the white LED will stop flashing. When configured, 3 beeps can also indicate a communications timeout during normal scanning mode. When using one-code-configuring, the scanner will beep three times: the current selected tone, followed by a short pause, a high tone and a low tone. This tells the user that the single configuration bar code has successfully configured the scanner.

Three Beeps - on power up This is a failure indicator. Refer to Failure Mode Indicators on page 21.

19

Page 24

SCANNER OPERATION Visual Indicators The QuantumT is equipped with a blue and white LED that indicates the scanner’s state and the status of the current scan when the unit is in operation.

Figure 13. Speaker Location and LED Location

No LEDs The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. They are also not illuminated when the laser is turned off for any reason. Steady Blue When the laser is active, the blue LED is illuminated. The blue LED will remain illuminated until the laser is deactivated. Steady Blue and Single White Flash When the scanner successfully reads a bar code, the white LED will flash and the scanner will beep once. If the white LED does not flash or the scanner does not beep once, then the bar code has not been successfully read. Steady White and Blue After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s white LED will remain on until the data can be transmitted. Alternating Blue and White Flashes This indicates the scanner is in configuration mode. A razzberry tone indicates that an invalid bar code has been scanned in this mode. Steady White, Blue Off This indicates the scanner may be waiting for communication from the host.

20

Page 25

SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsystem failure. Return the unit to an authorized service center for repair.

Flashing Blue and White and Two Razzberry Tones This indicates that the scanner has experienced a motor failure. Return the unit to an authorized service center for repair.

Continuous Razzberry Tone with Both LEDs Off If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an electronic failure. Return the unit to an authorized service center for repair.

Three Beeps - On Power Up If the scanner beeps 3 times on power up, then the nonvolatile memory that holds the scanner configuration has failed. Return the unit to an authorized service center for repair.

21

Page 26

SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code.

†

Figure 14. MS3580 Normal Depth of Field

* All specifications are subject to change without notice. † MS3580 shown with pedestal stand.

22

Page 27

SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code.

†

Figure 15. MS3580 Reduced Depth of Field

* All specifications are subject to change without notice. † MS3580 shown with pedestal stand.

23

Page 28

SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone

MINIMUM BAR CODE ELEMENT WIDTH A

B

C

D

E

F mm

.13

.15

.19

.25

.33

.66 mils

5.2

5.7

7.5

10

13

26

Figure 16. Normal Scan Zone by Bar Code Element Width

* All specifications are subject to change without notice.

24

Page 29

SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone

MINIMUM BAR CODE ELEMENT WIDTH A

B

C

D

E

F mm

.13

.15

.19

.25

.33

.66 mils

5.2

5.7

7.5

10

13

26

Figure 17. Reduced Scan Zone by Bar Code Element Width

* All specifications are subject to change without notice.

25

Page 30

SCANNER OPERATION IR Activation Range* QuantumT‘s default power save mode† is Laser OFF. This power save mode turns the laser off after a configured period of non-use. Any movement detected by the IR in the activation area will cause the scanner to exit power save mode. The laser will automatically turn back on preparing the scanner for bar code recognition, decoding and transmission.

Figure 18. Normal IR Activation Range

* All specifications are subject to change without notice. †

Refer to the MetroSelect Configuration Guide (00-02407) for additional information on configurable power save modes.