Page 41

DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER

DEFAULT OCIA USB

Supplements are not Required

*

Two Digit Redundancy

*

OR

RS232 TTL

LIGHT IBM PEN 46XX

KBW

LASER EMULATION

Five Digit Redundancy 100 msec to Find Supplement Configurable in 100msec steps (MAX 800 msec)

* as code 39

Coupon Code 128 Configurable Code Lengths

7 avail.

Configurable Prefix Characters

10 avail.

Configurable Suffix Characters

10 avail.

Prefixes for individual Code Types Editing Inter Scan-Code Delay Configurable (100 µsec steps)

800 µsec

Function/Control Key Support Configurable in 5.6 µsec steps Normal Depth of Field Reduced Depth of Field

38

1 msec

* as code 39

Page 42

DEFAULT SETTINGS - COMMUNICATION PARAMETERS RS232* PARAMETER

DEFAULT OCIA USB

Supplements are not Required

*

Two Digit Redundancy

*

OR

RS232 TTL

LIGHT IBM PEN 46XX

KBW

LASER EMULATION

Five Digit Redundancy 100 msec to Find Supplement Programmable in 100msec steps (MAX 800 msec)

* as code 39

Coupon Code 128 Programmable Code Lengths

7 avail.

Programmable Prefix Characters

10 avail.

Programmable Suffix Characters

10 avail.

Prefixes for individual Code Types Editing Inter Scan-Code Delay Programmable (100 µsec steps)

800 µsec

Function/Control Key Support Minimum Element Width Programmable in 5.6 µsec steps Normal Depth of Field Reduced Depth of Field

38

1 msec

* as code 39

Page 43

UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic’s new line of Flash- based scanners. This program allows the user of a Metrologic scanner to quickly upgrade to a new or custom version of firmware. It requires the use of a personal computer running Windows 95 or greater and the use of a serial port. The user merely connects the scanner to a serial port on the PC, launches the MetroSet2 program, and blasts off to new software upgrades. Each MS3580, regardless of the version number or communication protocol, can be upgraded. All RS232 (-41); keyboard wedge (-47); light pen (-41); OCIA (-9); IBM 468X/469X (-11); low speed USB (-38); integrated full speed USB (-40); and RS232 TTL, Laser Emulation (-104) units can be upgraded. To upgrade all units, a power supply and a PowerLink cable (MLPN 54-54014) are required. RS232 units can be upgraded using the standard PowerLink cable (MLPN 54-54000x-3). The program guides the user with its simplistic one click approach. The user must first select the file. Once the file is selected and verified, the scanner is ready to be upgraded. Press the “Flash Scanner” button to upgrade the scanner. The unit will go into a “flash mode” – both the blue and white LEDs will be on. The user can follow the progress of the upgrade by watching the screen for details. When the upgrade is complete, the scanner will respond with its normal one beep on power up. If two beeps occur, the scanner did not upgrade properly. Contact a Metrologic service representative for additional assistance.

39

Page 44

SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS3580 scanner interfaces terminate to a 10-pin modular socket. The serial # label indicates the interface enabled when the scanner is shipped from the factory.

Figure 19. Bottom View of MS3580 (Stand Removed)

MS3580-47 Keyboard Wedge and Stand-Alone Keyboard Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 PC Data 5 PC Clock 6 KB Clock 7 PC +5V 8 KB Data 9 +5VDC 10 Shield Ground

Pin 1 2 3 4 5 6 7 8 9 10

40

MS3580-40 Full Speed USB Function Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input USB D+ V USB USB D+5VDC Shield Ground

MS3580-41 RS232C and Light Pen Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input/LTPN Source 7 Reserved 8 LTPN Data 9 +5VDC 10 Shield Ground MS3580-38 RS232 Low Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 D+ 7 V USB 8 D9 +5VDC 10 Shield Ground

Page 45

SCANNER AND CABLE TERMINATIONS MS3580-11 IBM 468X/469X

MS3580-9 OCIA

Pin

Function

Pin

Function

1 2 3 4 5 6 7

Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input DTR Input IBM B-Transmit

1 2 3 4 5 6 7

8

IBM A+ Receive

8

9 10

+5VDC Shield Ground

9 10

Ground RS232 Transmit Output RS232 Receive Input RDATA RDATA Return Clock In Clock Out Clock in Return/ Clock out Rtrn +5VDC Shield Ground

MS3580-104 RS232 TTL, Laser Emulation Pin 1 2 3 4 5 6 7 8 9 10

Function Ground RS232 Transmit Output RS232 Receive Input RTS Output (TTL RS232) / Flip Sense CTS Input (TTL RS232) / Trigger Emulation Output DTR Input (TTL RS232) / Scan Enable Receive (TTL RS232) / Good Read Transmit (TTL RS232) / Scan Data +5VDC Shield Ground

41

Page 46

SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable MLPN 54-54000x -3 straight Pin

Function

1

Shield Ground

2

RS232 Transmit Output

3

RS232 Receive Input

4

DTR Input/Light Pen Source

5

Power/Signal Ground

6

Light Pen Data

7

CTS Input

8

RTS Output

9

+5VDC

9

5

6

1

9-Pin D-Type Connector

USB Power/Communication Cable MLPN 54-54213x-N-3, 54-54214x-N-3 or 54-54235x-N-3 Pin Function 1

PC +5V/V_USB

2

D-

3

D+

4

Ground

Shield Shield

USB Type A Locking with Power

USB Non-Locking

Stand Alone Keyboard PowerLink Cable MLPN 54-54020x-3 Pin 1 2 3 4 5 6

42

Function PC Data No Connect Power Ground +5VDC PC Power to KB PC Clock No Connect

6-Pin Male Mini-DIN Connector

Page 47

SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 54-54002x -3 Pin 1 2 3 4 5 Pin 1 2 3 4 5 6

Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC Function PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect

5-Pin DIN, Female

6-Pin DIN, Male

Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC. Keyboard Wedge Adapter Cable Pin

Function

1

PC Clock

2

PC Data

3

No Connect

4

Power Ground

5

+5 Volts DC

Pin

Function

1

Keyboard Data

2

No Connect

3

Power Ground

4

+5 Volts DC

5

Keyboard Clock

6

No Connect

5-Pin DIN, Male

6-pin Mini DIN, Female

43

Page 48

REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1

Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2

Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard.

Atención La modificación de los procedimientos, o la utilización de controles o ajustes distintos de los especificados aquí, pueden provocar una luz de láser peligrosa. Bajo ninguna circunstancia el usuario deberá realizar el mantenimiento del láser del escáner. Ni intentar mirar al haz del láser incluso cuando este no esté operativo. Tampoco deberá abrir el escáner para examinar el aparato. El hacerlo puede conllevar una exposición peligrosa a la luz de láser. El uso de instrumentos ópticos con el equipo láser puede incrementar el riesgo para la vista.

Attention L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou le laser. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez à une rayonnement laser qú êst hazardous. L'emploi d'appareils optiques avec cet équipement laser augmente le risque d'endommagement de la vision.

Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät hineinzusehen. Wenn Sie dies tun, können Sie sich einer gefährlichen Laserstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung.

Attenzione L’utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale può provocare delle esposizioni a raggi laser rischiose. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa. L’uso di apparecchi ottici, equipaggiati con raggi laser, aumenta il rischio di danni alla vista.

44

Page 49

REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022

Immunity CISPR 24, EN 55024

Class A Devices Unintentional Radiators The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3 métres (9.8 pieds) de long en extension maximale: Folgendes trifft zu, wenn das Scannerkabel länger als 3 Meter ist: This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense. Any unauthorized changes or modifications to this equipment could void the user’s authority to operate this device. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Notice This Class A digital apparatus complies with Canadian ICES-003.

Remarque Cet appareil numérique de classe A est conforme à la norme canadienne NMB-003.

European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Funkstöreigenschaften nach EN55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen. In diesem Fall kann vom Betreiber verlangt werden, angemessene Massnahmen durchzuführen.

Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure. Attention Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la cause d’interférences radio. Dans ce cas l’utiliseteur peut être amené à predre les mesures adéquates.

45

Page 50

REGULATORY COMPLIANCE EMC Class B Devices Unintentional Radiators The following is applicable when the scanner cable is less than 3 meters (9.8 feet) in length when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner ne dépassant pas 3 métres (9.8 pieds) de long en extension maximale: Folgendes trifft zu, wenn das Scannerkabel kürzer als 3 Meter ist: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help Notice This Class B digital apparatus complies with Canadian ICES-003. Remarque Cet appareil numérique de classe B est conforme à la norme canadienne NMB-003.

46