Page 51

User Configurable Suffixes, All Data Note: Scan the Enter/Exit Configuration mode code before trying to set this feature. Refer to Multi-Code Method on page 1–1. ~ Configurable Suffix Character #1 – A suffix ID can be added and assigned for data transmission. Use this code with a 3 code byte sequence, on page 16–1, which represents the desired character.

³

9

0

4

5

0

0

³

9

0

4

6

0

0

~ Configurable Suffix Character #2 – Assigns a second configurable suffix character.

³

9

0

4

7

0

0

~ Configurable Suffix Character #3 – Assigns a third configurable suffix character.

³

9

0

4

8

0

0

~ Configurable Suffix Character #4 – Assigns a fourth configurable suffix character.

³

9

0

4

9

0

0

~ Configurable Suffix Character #5 – Assigns a fifth configurable suffix character.

³

9

0

5

0

0

0

~ Configurable Suffix Character #6 – Assigns a sixth configurable suffix character.

³

9

0

5

1

0

0

~ Configurable Suffix Character #7 – Assigns a seventh configurable suffix character.

³

9

0

5

2

0

0

~ Configured Suffix Character #8 – Assigns an eighth configurable suffix character.

³

9

0

5

3

0

0

~ Configurable Suffix Character #9 – Assigns a ninth configurable suffix character.

³

9

0

5

4

0

0

~ Configurable Suffix Character #10 – Assigns a tenth configurable suffix character.

³

9

9

9

9

8

4

* Clear All User Configurable Suffixes

8–9

Page 52

Special Formats Enable SINEKO Mode ³

1

0

7

9

1

4

³

1

0

7

9

0

4

³

1

1

6

7

1

1

³

1

1

6

7

0

1

³

1

1

6

7

1

0

³

1

1

6

7

0

0

³

1

0

8

0

1

7

³

1

0

8

0

0

7

³

1

1

6

7

1

3

³

1

1

6

7

0

3

³

1

2

4

7

1

5

³

1

2

4

7

0

5

* Disable SINEKO Mode Enable Newcode Formatting Mode A * Disable Newcode Formatting Mode A Enable Newcode Formatting Mode B * Disable Newcode Formatting Mode B Remove All Leading Zero’s * Do Not Remove Leading Zero’s Enable MS951 CAPS Lock * Disable MS951 CAPS Lock Enable HCA Parsing Disable HCA Parsing

8–10

Page 53

9 Code Formatting UPC/EAN Formatting * Transmit UPC-A Check Digit ³

1

0

7

5

1

7

³

1

0

7

5

0

7

³

1

0

7

5

1

6

³

1

0

7

5

0

6

³

1

0

7

5

1

5

³

1

0

7

5

0

5

³

1

0

7

6

0

2

³

1

0

7

6

1

2

³

1

0

7

5

1

0

³

1

0

7

5

0

0

³

1

0

7

5

1

4

³

1

0

7

5

0

4

Do Not Transmit UPC-A Check Digit Transmit UPC-E Check Digit * Do Not Transmit UPC-E Check Digit Expand UPC-E to 12 Digits – Expand UPC-E bar codes to the 12 digit equivalent, UPC-A bar codes. * Do Not Expand UPC-E to 12 Digits * Send Number System on Expanded UPC E Do Not Send Number System on Expanded UPC E Enable GTIN Formatting * Disable GTIN Formatting Convert UPC-A to EAN-13 – The scanner converts UPC-A to EAN-13 by transmitting a leading zero before the bar code. * Do Not Convert UPC-A to EAN-13

9–1

Page 54

³

1

0

7

5

1

3

³

1

0

7

5

0

3

³

1

0

7

5

1

2

³

1

0

7

5

0

2

³

1

0

7

5

1

1

³

1

0

7

5

0

1

³

1

0

7

6

1

1

³

1

0

7

6

0

1

³

1

0

7

6

1

0

³

1

0

7

6

0

0

³

1

0

7

9

1

0

³

1

0

7

9

0

0

³

1

0

7

9

1

2

³

1

0

7

9

0

2

Transmit Lead Zero on UPC-E – This option will transmit a zero before each UPC-E bar code. Do Not Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 – The scanner will transmit five zeros before the bar code to convert EAN-8 to EAN-13. * Do Not Convert EAN-8 to EAN-13 * Transmit UPC-A Number System Do Not Transmit UPC-A Number System * Transmit UPC-A MFR # Do Not Transmit UPC-A MFR # * Transmit UPC-A ITEM # Do Not Transmit UPC-A ITEM # * Transmit EAN-8 Check Digit Do Not Transmit EAN-8 Check Digit * Transmit EAN-13 Check Digits – The scanner will transmit EAN-13 Check Digit. Do Not Transmit EAN-13 Check Digit.

9–2

Page 55

Codabar Formatting ³

1

0

7

7

1

7

³

1

0

7

7

0

7

³

1

1

5

1

0

0

³

1

1

5

1

1

0

³

1

0

7

7

1

6

³

1

0

7

7

0

6

³

1

0

0

4

1

0

³

1

0

0

4

0

0

³

1

0

0

4

1

1

³

1

0

0

4

0

1

³

1

0

8

0

0

6

³

1

0

8

0

1

6

Transmit Codabar Start/Stop Characters – Transmits Codabar’s Start/stop characters before and after each bar code. * Do Not Transmit Codabar Start/Stop * Normal Codabar Start/Stop Characters Enable Transmit Codabar Start/Stop Characters as Lower Case Characters Enable CLSI Editing – Works only with 14 digit Codabar type lengths. This option will perform CLSI type editing before the information is transmitted to the host. * Do Not Enable CLSI Editing Enable Codabar Mod-16 Check Digit * Disable Codabar Mod-16 Check Digit Enable Codabar “7-Check” Check Digit * Disable Codabar “7-Check” Check Digit * Transmit Codabar Check Digit Don’t Transmit Codabar Check Digit

9–3

Page 56

Code 39 Formatting ³

1

0

7

7

1

5

³

1

0

7

7

0

5

³

1

0

7

7

1

0

³

1

0

7

7

0

0

³

1

0

7

7

1

2

³

1

0

7

7

0

2

Transmit Mod 43 Check Digit on Code 39 – This feature works in conjunction with Mod 43 Check Digit on Code 39 option, on page 2–2. Both must be enabled for this feature to work. * Do Not Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop/Start Characters – The scanner transmits Code 39’s start and stop characters before and after each bar code. * Do Not Transmit Code 39 Stop/Start Characters Transmit an “A” (41H) Prefix if Italian Pharmaceutical * Do not Transmit an “A” (41H) Prefix if Italian Pharmaceutical

Code 11 Formatting ³

1

0

7

7

1

3

³

1

0

7

7

0

3

Transmit Code 11 Check Digit – This bar code will transmit Code 11 check characters when used with Enabled Code 11 on page 2–6. * Do Not Transmit Code 11 Check Digit

Telepen Enable Convert Telepen ^L to E ³

1

0

7

8

1

4

³

1

0

7

8

0

4

* Disable Convert Telepen ^L to E

9–4

Page 57

Plessey ³

1

0

7

8

1

6

³

1

0

7

8

0

6

³

1

0

7

8

1

5

³

1

0

7

8

0

5

³

1

0

7

7

1

1

³

1

0

7

7

0

1

Transmit UK Plessey Check Digit – The scanner will transmit UK Plessey Check Digit characters and must be used with the UK Plessey option. * Do Not Transmit UK Plessey Check Digit Enable UK Plessey Special Format Disable UK Plessey Special Format Transmit MSI Plessey Check Digit – This option works in conjunction with one or both of the Enabled MSI Plessey Mod options on page 2–7. * Do Not Transmit MSI Plessey Check Digit

2 of 5 Code Formatting ³

1

0

7

7

1

4

³

1

0

7

7

0

4

³

1

0

7

8

1

2

³

1

0

7

8

0

2

Transmit Mod 10 Check Digit on ITF – The scanner transmits interleaved 2 of 5 (ITF) Mod 10 check character. * Do Not Transmit Mod 10 Check Digit on ITF – Works in conjunction with Mod 10 check on ITF. Both must be enabled for this feature to work. Transmit Matrix 2 of 5 Check Digit * Do Not Transmit Matrix 2 of 5 Check Digit

9–5

Page 58

9–6

Page 59

10 RS232 ³

4

1

5

5

5

* Enable RS232 Mode – The scanner will work with RS232 +/-12V serial output.

4

Parity Features A parity bit is an extra data bit used to help catch data transmission errors. The scanner’s parity must match the host’s parity. No Parity ³

3

1

6

0

4

5

³

3

1

6

0

0

5

³

3

1

6

0

1

5

³

3

1

6

0

2

5

Even Parity – Select to set the parity bit to either a 1 or 0 to ensure an even number of bits are 1s.

³

3

1

6

0

3

5

Mark Parity – Select Mark Parity to set the parity bit always to 1.

Odd Parity – Select to set the parity bit to either a 1 or a 0 to ensure an odd number of bits are 1s. * Space Parity – Select to set the parity bit always to 0.

Baud Rate ³

4

1

5

8

1

0

0

³

4

1

5

8

9

0

³

4

1

5

8

8

0

³

4

1

5

8

7

0

³

4

1

5

8

6

0

115200 BAUD Rate (Not available with Voyager) 57600 BAUD Rate (Not available with Voyager) 38400 BAUD Rate 19200 BAUD Rate 14400 BAUD Rate

10–1

Page 60

* 9600 BAUD Rate ³

4

1

5

8

5

0

³

4

1

5

8

4

0

³

4

1

5

8

3

0

³

4

1

5

8

2

0

³

4

1

5

8

1

0

³

4

1

5

8

0

0

4800 BAUD Rate 2400 BAUD Rate 1200 BAUD Rate 600 BAUD Rate 300 BAUD Rate

Data/Stop Bits ³

1

1

6

0

1

3

³

1

1

6

0

0

3

³

1

1

6

0

1

4

³

1

1

6

0

0

4

8 Data Bits – The number of data bits transmitted for each character. * 7 Data Bits 1 Stop Bit * 2 Stop Bits

Hardware Handshaking ³

1

1

5

8

1

6

³

1

1

5

8

0

6

Enable RTS/CTS Handshaking – Output a Request to Send (RTS) signal and wait for a Clear to Send (CTS) signal before transmitting data. * Disable RTS/CTS Handshaking.

10–2