The text of a manual · part 5 of 12
MetroSelect Single-Line Scanner Configuration Guide, pages 41 to 50
Pages 41 to 50 of 116
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Metrologic MS1690
Page 41
³
1
1
5
9
1
6
³
1
1
5
9
0
6
³
1
1
8
1
1
1
³
1
1
8
1
0
1
³
1
1
8
3
1
1
³
1
1
8
3
0
1
³
9
9
9
9
6
9
³
1
1
8
2
1
3
³
1
1
8
2
0
3
³
1
2
5
0
1
6
³
1
2
5
0
0
6
³
1
2
5
0
1
3
³
1
2
5
0
0
3
Transmit Scanner ID byte with receipt of an “i” (69H) via RS232 – The ID byte is transmitted as 3 bytes (i.e. 0, 0, 1). * Don’t Transmit Scanner ID byte with receipt of an “i” (69H) via RS232 Transmit NO READ if DC2 Activated * Do Not Transmit NO READ if DC2 Activated No Green LED During NO READ Transmit * Green LED During NO READ Transmit Transmit Serial Number Enable Motor On/Off Commands * Disable Motor On/Off Commands Disable RS232 Receive Normal RS232 Receive Enable Banco Control Mode Disable Banco Control Mode
7–9
Page 42
³
1
4
1
7
1
5
³
1
4
1
7
0
5
³
1
1
9
9
1
7
³
1
1
9
9
0
7
Use Protocol Prefix and Suffix for Bar Code Transmission * No Protocol Prefix and Suffix for Bar Code Transmission Enable RTS on No Read – After a NOREAD occurs, the scanner will activate the RTS line for 20 milliseconds. The duration of the RTS activation can be loaded in address 199 bits 6–0 in 10 millisecond steps. * Disable RTS on No Read
Test Modes ³
1
1
8
0
1
6
³
1
1
8
0
0
6
³
1
1
5
5
1
2
³
1
1
5
5
0
2
Scan Count Mode ON – The scanner will enter scan count test mode and the scanner’s firmware number will transmit to the host. Do not enable unless instructed by a Honeywell representative. * Scan Count Mode OFF
7–10
Power-Up with Saved Interface – Do not enable unless instructed by a Honeywell representative. * Power-Up with Board Interface – Do not enable unless instructed by a Honeywell representative.
Page 43
8 Prefixes/Suffixes Scan the Enter Configuration Mode bar code before trying to set these features (see the Multi-Code Method on page 1–1).
User Configurable Prefixes, All Data ~ Configurable Prefix Character #1 – A prefix ID can be added and assigned for data transmission. Use this code with a code byte sequence, on page 16–1, which represents the desired character.
³
9
0
3
5
0
0
³
9
0
3
6
0
0
~ Configurable Prefix Character #2 – Assigns a second configurable prefix character.
³
9
0
3
7
0
0
~ Configurable Prefix Character #3 – Assigns a third configurable prefix character.
³
9
0
3
8
0
0
~ Configurable Prefix Character #4 – Assigns a fourth configurable prefix character.
³
9
0
3
9
0
0
~ Configurable Prefix Character #5 – Assigns a fifth configurable prefix character.
³
9
0
4
0
0
0
~ Configurable Prefix Character #6 – Assigns a sixth configurable prefix character.
³
9
0
4
1
0
0
~ Configurable Prefix Character #7 – Assigns a seventh configurable prefix character.
³
9
0
4
2
0
0
~ Configurable Prefix #8 – Assigns an eighth configurable prefix character.
³
9
0
4
3
0
0
~ Configurable Prefix Character #9 – Assigns a ninth configurable prefix character.
³
9
0
4
4
0
0
~ Configurable Prefix Character #10 – Assigns a tenth configurable prefix character.
³
9
9
9
9
8
5
* Clear All User Configurable Prefixes
8–1
Page 44
User Configurable ID Characters, Code Specific ³
1
0
5
5
0
7
³
1
0
5
5
1
7
* Use Configurable Code ID Bytes as Prefixes – User configured, code specific ID bytes are transmitted before the data. If using prefixes, user configured suffixes cannot be used. Use Configurable Code ID Bytes as Suffixes – User configured, code specific ID bytes are transmitted after the data. If using suffixes, user configured prefixes cannot be used.
‡ Enter configuration mode then scan this bar code followed by the three code byte bar codes (on page 16–1) that represent a unique ID character to be associated with this bar code type. ~ Configurable UPC-A ID ‡ ³
9
0
5
6
0
0
³
9
0
5
7
0
0
³
9
0
5
8
0
0
³
9
0
5
9
0
0
³
9
0
6
0
0
0
³
9
0
6
1
0
0
³
9
0
6
3
0
0
³
9
0
6
4
0
0
³
9
0
6
2
0
0
~ Configurable UPC-E ID ‡ ~ Configurable EAN-8 ID ‡ ~ Configurable EAN-13 ID ‡ ~ Configurable Code 39 ID ‡ ~ Configurable Code 128 ID ‡ ~ Configurable Code 93 ID ‡ ~ Configurable Code 11 ID ‡ ~ Configurable Telepen ID ‡
8–2
Page 45
‡
Enter configuration mode then scan this bar code followed by the three code byte bar codes (on page 16–1) that represent a unique ID character to be associated with this bar code type. ~ Configurable TRI-OPTIC ID ‡ ³
9
0
7
2
0
0
³
9
0
7
1
0
0
³
9
0
6
7
0
0
³
9
0
6
8
0
0
³
9
0
6
9
0
0
³
9
0
6
5
0
0
³
9
0
7
0
0
0
³
9
0
6
6
0
0
³
9
9
9
9
8
3
³
1
0
5
5
1
6
³
1
0
5
5
0
6
³
1
2
4
7
1
6
³
1
2
4
7
0
6
~ Configurable Standard 2 of 5 ID ‡ ~ Configurable Interleaved 2 of 5 ID ‡ ~ Configurable Matrix 2 of 5 ID ‡ ~ Configurable Airline 2 of 5 ID ‡ ~ Configurable MSI Plessey ID ‡ ~ Configurable UK Plessey ID ‡ ~ Configurable Codabar ID ‡ * Clear All Configurable Code Specific ID’s – Clears all unique ID characters previously identified. Enable Teraoka ID * Disable Teraoka ID Enable Taiwan 7-11 ID * Disable Taiwan 7-11 ID
8–3
Page 46
Standard Prefix Characters ³
1
1
6
6
1
5
³
1
1
6
6
0
5
³
1
0
5
5
1
3
³
1
0
5
5
0
3
³
1
0
7
9
1
5
³
1
0
7
9
0
5
³
1
1
6
6
1
7
³
1
1
6
6
0
7
³
1
0
7
9
1
1
³
1
0
7
9
0
1
³
9
4
1
5
0
0
³
1
0
7
9
1
7
³
1
0
7
9
0
7
Enable STX Prefix – The scanner will transmit a Start of TeXt (ASCII 02H) before each bar code. * Disable STX Prefix Enable Rochford-Thomson Mode * Disable Rochford-Thomson Mode Enable AIM ID Characters * Disable AIM ID Characters Enable UPC Prefix ID – A prefix will be transmited before any UPC/EAN code. The prefixes are A (UPC-A), E0 (UPC-E), F (EAN-13), and FF (EAN-8). * Disable UPC Prefix ID. Enable NCR Prefix ID – A prefix will be transmitted before the following code types. The prefixes are as follows: A (UPC-A), E0 (UPC-E), FF (EAN-8), F (EAN 13), B1 (Code 39) B2 (ITF), B3 (Code 128 and other codes). * Disable NCR Prefix ID Enable NCR Prefix Character Enable Nixdorf ID Characters – This option transmits code identities before each bar code for many Siemen/Nixdorf registers. * Disable Nixdorf ID Characters
8–4
Page 47
Enable SANYO ID Characters ³
1
0
7
9
1
6
³
1
0
7
9
0
6
³
1
0
5
5
1
2
³
1
0
5
5
0
2
³
1
0
5
5
1
1
³
1
0
5
5
0
1
³
1
0
5
5
1
0
³
1
0
5
5
0
0
³
1
1
6
6
1
1
³
1
1
6
6
0
1
³
1
1
6
1
1
1
³
1
1
6
1
0
1
³
1
1
6
1
1
3
³
1
1
6
1
0
3
* Disable SANYO ID Characters Enable Manufacturer ID Prefix * Disable Manufacturer ID Prefix Enable “C” Prefix * Disable “C” Prefix Enable “$” Prefix ID for UPC/EAN * Disable “$” Prefix ID for UPC/EAN Enable Tab Prefix – The scanner will transmit a TAB (ASCII 09H) before each bar code. * Disable Tab Prefix Enable SNI Beetle Mode * Disable SNI Beetle Mode Enable Cipher 1021 IDs * Disable Cipher 1021 IDs
8–5
Page 48
Enable Tec 7-11 IDs ³
1
2
4
6
1
0
³
1
2
4
6
0
0
* Disable Tec 7-11 IDs
Standard Suffix Characters * Enable CR Suffix – The scanner transmits a ³
1
1
6
6
1
3
³
1
1
6
6
0
3
³
1
1
6
6
1
2
³
1
1
6
6
0
2
³
1
1
6
6
1
0
³
1
1
6
6
0
0
³
1
1
6
6
1
4
³
1
1
6
6
0
4
³
1
1
6
6
1
6
³
1
1
6
6
0
6 carriage return after each bar code. Disable CR Suffix.
* Enable LF Suffix – The scanner transmits a line feed after each bar code. Disabled when keyboard wedge defaults are loaded. Disable LF Suffix. Enable Tab Suffix – The scanner will transmit a TAB (ASCII 09H) after each bar code. * Disable Tab Suffix Enable ETX Suffix – The scanner will transmit End of TeXt (ASCII 03H) after the bar code date. * Disable ETX Suffix Enable UPC Suffix ID – The scanner will transmit a suffix after any UPC/EAN bar code. The suffixes are A (UPC-A), E (UPC-E), F (EAN-13) and F (EAN-8). * Disable UPC Suffix ID
8–6
Page 49
Enable NCR Suffix Character ³
9
4
1
6
0
0
Longitudinal Redundancy Check A Longitudinal Redundancy Check (LRC) is an error checking character that is calculated across a sequence of data characters. It is determined by eXclusive ORing (XOR) the characters to be checked, starting with an initial value of 00H. The result, an “LRC byte” is then transmitted following the data stream and used by the receiving computer to determine if the information was received correctly. In the scanner’s case, XOR is performed prior to adding parity bits. When the LRC is enabled, the scanner defaults to starting the LRC on the second byte of information transmitted. Optionally, the calculation can start on the first byte transmitted.
³
1
0
7
8
1
1
³
1
0
7
8
0
1
³
1
0
7
8
0
0
³
1
0
7
8
1
0
Enable Transmit of LRC Calculation – The scanner outputs on LRC check character after the bar code. * Disable Transmit of LRC Calculation. * Start LRC on First Byte – The scanner will calculate the LRC check digit starting with the first character. Start LRC on Second Byte – The scanner will calculate the LRC check digit starting with the second character.
Block Check Character * Enable NCR BCC ³
1
4
1
4
0
0
³
1
4
1
4
1
0
Disable NCR BCC
8–7
Page 50
Character Replacements To replace a character: 1.
Scan the enter/exit configuration mode bar code (on page 1–1).
2.
Scan the character to replace code (shown below).
3.
Scan the ASCII code byte value of the character you wish to replace. Refer to the ASCII Reference Table in the Code Byte Usage section of this manual.
4.
Scan the replacement character bar code (shown below).
5.
Scan the ASCII code byte value of the replacement character.
6.
Scan the enter/exit configuration mode bar code (on page 1–1). ~ Character to Replace
³
9
3
8
6
0
0
³
9
3
8
7
0
0
³
8
3
8
6
0
0
~ Replacement Character
No Replacement
8–8