Page 61
* Character RTS/CTS – Activates/Deactivates RTS signal for each character.
³
1
1
5
8
1
5
³
1
1
5
8
0
5
³
1
2
4
5
1
0
³
1
2
4
5
0
0
³
1
2
4
5
1
1
³
1
2
4
5
0
1
³
1
2
4
5
1
2
³
1
2
4
5
0
2
* Activate RTS, Wait for CTS – Wait for CTS after activating RTS.
³
1
2
4
5
1
3
Test CTS Not Present Before RTS (RSV4) – Do not activate RTS if CTS is already present.
³
1
2
4
5
0
3
³
1
1
5
8
1
7
³
1
1
5
8
0
7
Message RTS/CTS – Activates RTS before sending the first character and leaves it active until after the last character has been transmitted. Invert RTS Polarity (RSV1) -12V = Active +12V = Inactive * Standard RTS Polarity – Use standard RTS polarity -12V = Inactive +12V = Active Invert CTS Polarity (RSV2) -12V = Active, +12V = Inactive, OK to send Do not send * Standard CTS Polarity -12V = Inactive, Do not send
+12V = Active, OK to send
Activate RTS, Do Not Wait for CTS (RSV3) – Activate RTS for transmission but do not wait for CTS to send.
* Do Not Test for CTS Present Before RTS
Enable DTR Support – The scanner will stop scanning when the Data Terminal Ready (DTR) signal goes inactive. * Disable DTR Support
10–3
Page 62
³
1
1
5
9
1
5
³
1
1
5
9
0
5
³
1
1
5
9
1
4
³
1
1
5
9
0
4
Enable RTS Counter Toggle – The scanner will toggle the RTS line on a good decode. * Disable RTS Counter Toggle
Enable XON/XOFF Handshaking – The scanner will stop transmission whenever on XOFF (ASCII 13H) is received. Transmission will resume after an XON (ASCII 11H) is received. * Disable XON/XOFF Handshaking.
Software Handshaking ³
1
1
5
9
1
3
³
1
1
5
9
0
3
³
1
1
5
9
1
1
³
1
1
5
9
0
1
³
1
1
8
0
1
3
³
1
1
8
0
0
3
Enable ACK/NAK – After transmitting data, wait for an ACK (06H) or a NAK (15H) response from the host. If ACK is received, complete the communications cycle and look for more bar codes. If NAK is received, retransmit the last set of bar code data and wait for ACK/NAK again. * Disable ACK/NAK Support BEL/CAN in ACK/NAK – When BEL (07H) is received, the scanner beeps 3 times and exits the communications loop. If a CAN (18H) is received, then the scanner will exit the communications loop, silently. * Ignore BEL/CAN in ACK/NAK – Ignore BEL/CAN characters in communication loop. Enable 5 Retries on ACK/NAK Time Out – Allow up to 5 NAK retransmissions of the data before dropping out of the communications loop. * Disable 5 Retries on ACK/NAK Time Out
10–4
Page 63
³
1
1
5
8
1
4
³
1
1
5
8
0
4
³
1
2
5
2
1
0
³
1
2
5
2
0
0
Enable 5 NAK Retries Allow up to 5 retransmissions of the data if a NAK is received. * Disable 5 NAK Retries Enable GLS Handshaking – Accept ]V for the ACK acknowledgement. ACK will no longer be accepted but NAK and any additional ACK/NAK protocol characters enabled are still accepted. * Disable GLS Handshaking
Miscellaneous ³
1
1
6
1
1
0
³
1
1
6
1
0
0
³
1
4
1
4
1
6
³
1
4
1
4
0
6
Enable French PC Term – The scanner transmits PC type make/break scan codes instead of ASCII data characters. The scan codes match a WYSE French PC Term. * Disable French PC Term Enable NCR Scanner – Only Commands
* Disable NCR Scanner – Only Commands
10–5
Page 64
10–6
Page 65
11 Keyboard Enable Keyboard Emulation Load Keyboard Wedge Defaults – Loads the default settings for keyboard wedge mode.
³
9
9
9
9
9
4
³
5
1
5
5
1
5
3
³
5
1
5
5
1
4
3
Enable Stand-Alone Keyboard Emulation – Use this with special stand-alone models that are not cabled for an external keyboard. Scan this bar code to enable the Stand-Alone Mode. The scanner will send keyboard “power on” information and configure hardware to simulate a constant keyboard connection. * Enable Keyboard Wedge Emulation – Use this with an external keyboard. Transmit in wedge made to allow standard PC keyboards to communicate when no bar code data is available.
Country/Scan Code Table Selects * USA Keyboard ³
4
1
6
2
6
0
³
4
1
6
2
8
0
³
4
1
6
2
5
0
³
4
1
6
2
4
0
³
4
1
6
2
3
0
³
4
1
6
2
2
0
³
4
1
6
2
1
0
Switzerland Keyboard Spain Keyboard Italy Keyboard Germany Keyboard France Keyboard UK Keyboard
11–1
Page 66
Belgium Keyboard ³
4
1
6
2
0
0
³
4
1
6
2
1
0
³
4
1
6
2
7
0
³
4
1
6
2
9
0
³
4
1
6
2
1
Japan Keyboard 0
IBM 4700 Financial Keyboard Sweden/Finland Keyboard Slovenian Keyboard 1
0
Keyboard/System Type * AT Keyboard – Includes IBM PS/2 and compatible models 50, 55, 60, 80.
³
2
1
6
2
1
5
³
2
1
6
2
0
5
³
2
1
6
2
2
5
³
2
1
6
2
3
5
³
1
1
6
3
0
7
Enable XT Keyboard for Mode 1 – Special firmware in Voyager.
³
1
1
6
3
1
7
Enable XT Keyboard for Mode 2 – Special firmware in Voyager.
XT Keyboard – Special firmware in Voyager.
PS/2 Keyboard – Includes IBM PC and compatible models 30, 70, 8556. Enable Terminal Keyboard Emulation.
11–2
Page 67
‘Dumb’ Terminal Selections Note: The following terminals may require custom cables. IBM Terminal Keyboards ³
3
1
6
4
0
0
³
3
1
6
4
1
0
³
3
1
6
4
2
0
³
3
1
6
4
3
0
³
3
1
6
4
4
0
³
3
1
6
4
5
0
³
3
1
6
4
6
0
³
3
1
6
4
7
0
³
1
1
6
7
1
4
³
1
1
6
7
0
4
³
1
1
6
7
1
5
³
1
1
6
7
0
5
Reserved Terminal Keyboard #2 Reserved Terminal Keyboard #3 Reserved Terminal Keyboard #4 Reserved Terminal Keyboard #5 Reserved Terminal Keyboard #6 Reserved Terminal Keyboard #7 Reserved Terminal Keyboard #8
Lower Case Lock On – transmit all data as lower case. * Lower Case Lock Off
Spanish Keyboard Ñ Substitution – the following two characters will translate as follows: # to Ñ and ^ to ñ. * No Spanish Keyboard Ñ Substitution
11–3
Page 68
Special Keyboard Features ³
1
1
6
3
1
1
Transmit Make Code Only – Not available on all models.
³
1
1
6
3
0
1
* Transmit Make/Break Code – Not available on all models.
³
1
1
6
3
1
0
* Transmit FOH Break Code – The scanner will transmit the FOH in the break-code sequence.
³
1
1
6
3
0
0
³
1
1
6
3
1
5
³
1
1
6
3
0
5
³
1
1
6
2
1
7
³
1
1
6
2
0
7
Do Not Transmit FOH Break Code
Transmit Cleanup Bit – Use for certain NEC computers. * Do Not Transmit Cleanup Bit
Enable Alt-Mode – See Enable ALT-Mode (Normal) for description. * Disable Alt-Mode – Caution: If host software application uses the right Alt key as a “Hot” key, Alt-mode must be disabled.
† These settings only apply if the Alt-Mode (shown above) is enabled. †
³
1
1
6
7
0
6
³
1
1
6
7
1
6
* Enable Alt-Mode (Normal) The scanner will duplicate the following keyboard sequence; Hold down the Alt key and Type the three digit decimal number that corresponds to the appropriate character. †
11–4
Enable Alt-Mode (Advanced) The scanner will duplicate the following keyboard sequence; Hold down the Alt key and Type the four digit decimal number that corresponds to the appropriate character.
Page 69
Enable Auto Detect Mode (AT/PS2) – Automatically detects caps lock status.
³
1
1
6
2
1
4
³
1
1
6
2
0
4
³
1
1
6
2
1
4
³
1
1
6
2
0
4
³
1
1
6
3
1
6
³
1
1
6
3
0
6
³
1
1
6
4
1
0
³
1
1
6
4
0
0
³
1
1
6
3
0
3
* Use Extended ASCII To Send Extended Key Codes – Use extended ASCII characters to send PC keyboard keys e.g., F1, F2.
³
1
1
6
3
1
3
Use Extended ASCII Characters as Extended ASCII> – Transmit extended ASCII codes via Alt Mode.
³
1
1
6
3
0
4
³
1
1
6
3
1
4
* Disable Auto Detect Mode (AT/PS2)
Enable Caps Lock (XT)
* Disable Caps Lock (XT) Send Numbers as Keypad Data – All data is sent as if it has been entered on a keypad. * Send Numbers as Normal Data
Enable Reserved Feature
* Disable Reserved Feature
* Character KB Inhibit
Message KB Inhibit
11–5
Page 70
Enable Right Alt Key Sequencing ³
1
1
6
3
0
2
³
1
1
6
3
1
2
³
1
1
6
4
1
3
Enable LaCaixa Special Keyboard Prefix & Suffix Scan Codes
³
1
1
6
4
0
3
* Disable LaCaixa Special Keyboard Prefix & Suffix Scan Codes
Disable Right Alt Key Sequencing
InterScan Code Delays ³
8
1
6
5
8
³
8
1
6
5
7
³
8
1
³
9
11–6
6
1
5
6
1
5
* InterScan Code Delay 800 msec – The time specified represents the amount of time between individual 11-bit scan codes. This parameter may need to be adjusted for operation with certain PC keyboard BIOS.
0
5
0
5
0
0
0
0
InterScan Code Delay 7.5 msec – This time specified represents the amount of time between individual 9-bit scan codes. This parameter may need to be adjusted for operation with certain PC keyboard BIOS. InterScan Code Delay 15 msec – The time specified represents the amount of time between individual 11-bit scan codes. This parameter may need to be adjusted for operation with certain PC keyboard BIOS. ~ Variable InterScan Code Delay msec – Refer to Multi-Code Method on page 1–1. Sets value in 100 microsecond increments.