Page 31

FLEX STAND INSTALLATION 5.

Attach the scanner pedestal to the flex pole.

Figure 27: Attach Pedestal to Pole

6.

Slide the scanner onto the pedestal until it clicks locking the scanner to the stand.

Figure 28: Install Pedestal to Scanner

7.

Before installing the scanner’s cable cover, refer to pages 4-13 for instructions on the proper cable connections.

8.

Install the scanner’s cable cover.

Figure 29:Install Cable Cover

27

Page 32

EAS DEACTIVATION ANTENNA SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. Metrologic recommends end users program the MS7320 to the Fixed for Low Density Codes - Depth of Field*, so that the unit does not scan out beyond the deactivation range. Unit #

Checkpoint Recommended Switch Bank Settings

MS7320 Depth of Field Recommended Settings Fixed for Low Density Codes Depth of Field Adjustments*

MS7320

SW1 - 2, 3, 4, 5, 6 set to ON & SW2 - 2, 3, 4, 5, 6 set to ON ³

4

1

8

7

2

0

* Note: Minimum element width changes to 6.8 mil when in this mode.

Figure 30: EAS Deactivation Antenna

Contact Checkpoint Systems directly for additional EAS support.

28

Page 33

TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms.

MS7320 SERIES TROUBLESHOOTING GUIDE SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

All Interfaces No LEDs, beep or motor spin.

No power is being supplied to the scanner.

Check transformer, outlet and power strip. Make sure the cable is plugged into the scanner.

No LEDs, beep.

No power is being supplied to the scanner from host.

Some host systems cannot supply enough current to power MS7320 series scanner. Use the power supply included with the scanner.

3 beeps on power up.

Non-volatile RAM failure.

Contact a Metrologic Representative, if the unit will not hold the configuration.

Continuous razz tone on power up.

Diagnostic Failure.

Contact a Metrologic Representative, if the unit will not function.

VLD failure.

Contact a Metrologic Representative.

Scanner motor failure.

Contact a Metrologic Representative.

Multiple scans upon presentation of code.

Same symbol timeout set too short.

Adjust same symbol timeout for a longer time.

The unit powers up but does not beep.

Beeper disabled No volume is selected No tone is selected.

Enable beeper Select volume (configurable) Select tone.

Razz tone and green LED flash at power up.

29

Page 34

TROUBLESHOOTING GUIDE SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

Scanning a particular symbology that is not enabled.

UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected.

The scanner has been configured for a character length lock, or a minimum length and bar code being scanned does not satisfy the configured criteria.

Verify that the bar code that is being scanned falls into the criteria. (Typical of Non-UPC/EAN codes. The scanner defaults to a minimum of 4 character bar code.)

The unit scans a bar code, but locks up after the first scan (red LED stays on).

The scanner is configured to support some form of host handshaking but is not receiving the signal.

If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.

The unit scans, but the data transmitted to the host is incorrect.

The scanner’s data format does not match the host system requirements.

Verify that the scanner’s data format matches that required by the host. Make sure that the scanner is connected to the proper host port.

The unit powers up, but does not scan and/or beep.

30

Page 35

TROUBLESHOOTING GUIDE SYMPTOMS

Scanner beeps at some bar codes and NOT for others of the same bar code symbology.

Multi-Function Button is not working.

POSSIBLE CAUSE(S)

SOLUTION

The bar code may have been printed incorrectly.

Check if it is a check digit/character/or border problem.

The scanner is not configured correctly for this type of bar code.

Check if check digits are set properly.

The minimum symbol length setting does not work with the bar code.

Check if the correct minimum symbol length is set.

Dirt could be preventing Make sure the button area is clean and the button can move the button from freely. compressing fully. A faulty push button switch.

Contact a Metrologic Customer Service Representative.

Keyboard Wedge Only Configuration is not correct.

Make sure the scanner is configured for the appropriate mode.

The unit scans but the data is not correct.

Configuration is not correct.

Make sure that the proper PC type AT, PS2 or XT is selected. Verify correct country code and data formatting are selected. Adjust the intercharacter delay SYMPTOM.

The unit is transmitting each character.

Configuration is not correct.

Increase the interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.

Alpha characters show as lower case.

Computer is in Caps Lock mode.

Enable Caps Lock detect setting of the scanner to detect whether the PC is operating in Caps Lock.

The unit scans the bar code but there is no data.

31

Page 36

TROUBLESHOOTING GUIDE SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

Everything works except for a couple of characters.

These characters may not be supported by that country’s key look up table.

Try operating the scanner in Alt mode.

The unit is transmitting each character.

Configuration is not correct.

Increase the interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.

Alpha characters show as lower case.

Computer is in Caps Lock mode.

Enable the caps lock detect setting of the scanner to detect if the PC is operating in Caps Lock.

Everything works except for a couple of characters.

These characters may not be supported by that country’s key look up table.

Try operating the scanner in Alt mode.

RS232 Only

Power-up OK and scans OK but does not communicate properly to the host.

Com port at the host is not working or configured properly.

Com port not operating properly.

Cable not connected to the proper com port.

32

Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS232" data.

Page 37

TROUBLESHOOTING GUIDE SYMPTOMS

POSSIBLE CAUSE(S)

The host is The scanner and host receiving data but may not be configured the data does not for the same interface. look correct. Intercharacter delay needs to be added to the transmitted output.

Characters are being dropped.

SOLUTION Check that the scanner and the host are configured for the same interface. Add some intercharacter delay to the transmitted output by using the MetroSelect Configuration Guide (MLPN 00-02407).

Aux Port Operation with any Interface Trouble with the secondary scanner.

Secondary scanner powers up but data is not relayed to the host.

*

Refer to the user guide provided with the secondary scanner. Cable [MLPN 54-54667] may not be connected to the proper port.

The “Aux” com port may not be operating properly.

Ensure the secondary scanner is connected to the MS7320 com port marked “Aux” port. * The MS7320 must be configured to enable the “Aux” port. The secondary scanner must be configured to send ‘secondary’ formatted data (reserve code 32).

®

Use MetroSet . For the Auxiliary interface, choose “HoloTrak Decode”. All remaining parameters will be automatically chosen.

USB Only The scanner Powers up ok, scans ok but does not communicate.

The USB Port is not operating correctly.

The scanner emits a razz tone The USB port is not and the LEDS flash three times operating correctly. when configured for USB.

Check that the scanner is configured for USB operation. Check that the host’s USB port is enabled. Disconnect then reconnect the USB cable at the host end. Contact a Metrologic Representative if symptoms persist.

33

Page 38

DESIGN SPECIFICATIONS MS7320 SERIES DESIGN SPECIFICATIONS OPERATIONAL Light Source:

Visible Laser Diode (VLD) @ 650 nm

Laser Power:

0.678 mW (peak)

Depth of Field: Width of Scan Field:

0 mm to 215 mm (0"- 8.5") for 0.33 mm (13 mil) bar code 38 mm (1.5") @ 15 mm (0.6"); 135 mm (5.3") @ 191 mm (7.5")

Scan Speed:

2000 scans/second

Scan Pattern:

5 fields of 4 parallel lines (omnidirectional)

Scan Lines: Min Bar Width:

20 0.127 mm (5.0 mil)

Decode Capability:

Autodiscriminates all standard bar codes; for other symbologies call Metrologic

System Interfaces:

PC Keyboard Wedge, RS232, OCIA, Light Pen, Stand Alone PC Keyboard, USB, IBM 468x/469x

Print Contrast: No. Characters Read: Roll, Pitch, Yaw:

35% minimum reflectance difference up to 80 data characters (Maximum number will vary based on symbology and density) 360°, 60°, 60°

Beeper Operation:

7 tones or no beep

Indicators (LED):

green = laser on, ready to scan red = good read, decoding

MECHANICAL Dimensions: Footprint of Stand Weight: Termination: Cable:

185 mm (7.3") H, 99 mm (3.9") D, 168 mm (6.6") W 64 mm (2.5") x 64 mm (2.5") 1.2 Kg (2.65 lbs) Three 10-pin modular RJ45 jacks Standard 2.1m (7') straight; for other cables call Metrologic

Specifications are subject to change without notice.

34

Page 39

DESIGN SPECIFICATIONS MS7320 SERIES DESIGN SPECIFICATIONS ELECTRICAL Input Voltage:

5.2VDC ± 0.25V

Power: 1.9

W

Operating Current:

360 mA

DC Transformers:

Class II; 5.2 VDC @ 1A

For Regulatory Compliance Information refer to pages 51 -54.

ENVIRONMENTAL Operating Temperature:

0°C to 40°C (32°F to 104°F)

Storage Temperature:

-40°C to 60°C (-40°F to 140°F)

Humidity: Light Levels: Contaminants:

5% to 95% relative humidity, non-condensing Up to 4842 LUX (450 foot candles) Sealed to resist airborne particulate contaminants

Ventilation: None required

Specifications are subject to change without notice.

35

Page 40

RS232 DEMONSTRATION PROGRAM If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the com port is working, and the scanner is working. If the bar code data displays on the screen while using this program, it only demonstrates that the hardware interface and scanner are working. At this point, investigate whether the application software and the scanner configuration match. If the application does not support RS232 scanners, a software wedge program that will take RS232 data and place it into a keyboard buffer may be needed. This program tells the PC to ignore RTS-CTS, Data Set Ready (DSR) and Data Carrier Detect (DCD) signals. If the demonstration program works and yours still does not, jumper RTS to CTS and Data Terminal Reading (DTR) to DCD and DSR on the back of your PC.

10 CLS 20 ON ERROR GOTO 100 30 OPEN “COM1:9600,S,7,1,CS0,DS0,CD0,LF” AS #1 35 PRINT “SCAN A FEW BAR CODES” 40 LINE INPUT #1, BARCODE$ 50 PRINT BARCODE$ 60 K$ = INKEY$: IF K$ = CHR$(27) THEN GOTO 32766 70 GOTO 40 100 PRINT “ERROR NO.”; ERR; “ PRESS ANY KEY TO TERMINATE.” 110 K$ = INKEY$: IF K$ = “” THEN GOTO 110 32766 CLOSE: SYSTEM 32767 END

36