Page 41

APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol.

SCANNER

VERSION IDENTIFIER

7320

COMMUNICATION PROTOCOL(S)

13

RS232, IBM 46xx, OCIA, Aux

37

RS232, Light Pen, Keyboard Wedge, Stand-Alone Keyboard, USB, Aux

The MS7320 with Built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. Many RS232 configurable functions available in other Metrologic scanners are also available as keyboard wedge functions. The following are the most important selectable options specific to the keyboard wedge. Keyboard Type • ** AT (includes IBM® PS2 models 50, 55, 60, 80) • XT • IBM PS2 (includes models 30, 70, 8556)

Keyboard Country Type • ** USA • Belgium • F rench • German • Hungarian **

• Italian • Japanese • Russian Cyrillic • Slovenian • Spanish

• Sw iss • Sw edish/Finnish • Tu rkish • United Kingdom

Refer to pages 40-45 for complete information on the factory default settings. Refer to the MetroSelect Configuration Guide (MLPN 00-02407) or MetroSet 2’s help files for information on how to change the default settings.

37

Page 42

CONFIGURATION MODES The MS7320 has three modes of configuration. •

Bar Codes The MS7320 can be configured by scanning the bar codes included in the Metrologic Configuration Guide shipped with the area imager. This manual can also be downloaded FREE from Metrologic’s website (www.metrologic.com).

•

MetroSet2 This user-friendly Windows-based configuration program allows you to simply ‘point-and-click’ at the desired scanner options. This program can be downloaded for FREE from Metrologic’ website (www.metrologic.com) or setup disks can be ordered by calling 1-800-ID-METRO.

•

Serial Programming This mode of configuration is ideal for OEM applications. This mode gives the end-user the ability to send a series of commands using the serial port of the host system. The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Configuration Guide (MLPN 00-02407).

38

Page 43

UPGRADING THE FIRMWARE The MS7320 is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires, a new firmware file supplied to the customer by a customer service representative and Metrologic's MetroSet2 software . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is required to complete the upgrade. Do not use the standard cable supplied with Keyboard Wedge or RS485 MS7320 interface kits for firmware upgrades. If using USB or RS232 for the upgrade process, the standard USB or RS232 cable provided with the scanner can be used. To upgrade the firmware in the MS7320: 1.

Plug the scanner into a serial communication port on the host system.

2.

Start the MetroSet2 software.

3.

Click on the plus sign (+) next to POS Scanners to expand the supported scanner list.

4.

Choose the MS7320 InVista from the list.

5.

Click on the Configure InVista/7320 Scanner button.

6. Choose Flash Utility from the options list located on the left side of the screen. 7.

Click on the Open File button in the Flash Utility window.

8.

Locate and open the flash upgrade file supplied by Metrologic.

9.

Select the COM port that the scanner is connected to on the host system.

10. Verify the settings listed in the Flash Utility window. 11. Click on the Flash Scanner button to begin the flash upgrade. 12. A message will appear on the screen when the upgrade is complete.

Metrologic's customer service department can be reached at 1-800-ID-METRO or 1-800-436-3876. MetroSet2 is available for download, at no additional cost, from http://www.metrologic.com/corporate/download.

39

Page 44

DEFAULT SETTINGS Many functions of the scanner can be "configured" - that is, enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled. Every communication does not support every parameter. If the communication supports a parameter listed in the charts on the following pages, a check mark ( ) will appear. PARAMETER UPC/EAN Code 128 Code 93 Codabar Interleaved 2 of 5 (ITF)

DEFAULT

* * * * *

MOD 10 Check on ITF Code 11 Code 39

*

Full ASCII Code 39 MOD 43 Check on Code 39 MSI-Plessey Airline (15 Digit) 2 of 5 Airline (13 Digit) 2 of 5 Matrix 2 of 5 Telepen UK Plessey STD 2 of 5 MSI-Plessey 10/10 Check Digit MSI-Plessey MOD 10 Check Digit

*

Paraf Support ITF Symbol Lengths Minimum Symbol Length

Variable 4

Symbol Length Lock

None

Bars High as Code 39

*

40

OCIA

RS232

LIGHT PEN

IBM 46XX

KBW

USB

Page 45

DEFAULT SETTINGS PARAMETER

DEFAULT

OCIA

RS232

LIGHT PEN

IBM 46XX

KBW

USB

Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS DTS/NIXDORF

*

NCR F NCR S Poll Light Pen Source Beeper Tone

Normal

Beep/Transmit Sequence

Before Transmit

Beeper Volume

Loudest

CommunicationTimeout

None

Razzberry Tone on Timeout Three Beeps on Timeout No Beeps on Timeout

*

Enter Power Save Mode

10 mins.

Blink Power Save Mode

*

Laser OFF Power Save Mode Laser & Motor OFF Power Save Mode Dual Action Power Save Mode #1 Dual Action Power Save Mode #2 Same Symbol Rescan Timeout: 200 msecs Same Symbol Rescan Timeout: 500 msecs Configurable in 50 msec steps (MAX 6.35 seconds)

*

Same Symbol Rescan Timeout: 1250 msecs

41

Page 46

DEFAULT SETTINGS PARAMETER

DEFAULT

Same Symbol Rescan Timeout: 2000 msecs Intercharacter Delay Configurable in 1 msec steps (MAX 255 msecs)

1 msecs 10 msecs in KBW

Number of Scan Buffers

1

Transmit EAN-8 Check Digit

*

Transmit EAN-13 Check Digit

*

Transmit UPC-A Check Digit

*

Transmit UPC-E Check Digit Expand UPC-E Convert UPC-A to EAN-13 UPC GTIN-14 Format Transmit Lead Zero on UPC-E Convert EAN-8 to EAN-13 Transmit UPC-A Number System

*

Transmit UPC-A Manufacturer ID#

*

Transmit UPC-A Item ID#

*

Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop/Start Characters Transmit Mod 10/ITF Transmit MSI-Plessey Check Characters Parity

Space

Baud Rate

9600

42

OCIA

RS232

LIGHT PEN

IBM 46XX

KBW

USB

Page 47

DEFAULT SETTINGS PARAMETER

DEFAULT

OCIA

RS232

LIGHT PEN

IBM 46XX

KBW

USB

8 Data Bits 7 Data Bits

*

Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Transmit AIM ID Characters STX Prefix ETX Suffix Carriage Return

*

Line Feed - disabled by default in KBW

*

Tab Prefix Tab Suffix "DE" Disable Command "FL" Laser Enable Command DTR Handshaking Support RTS/CTS Handshaking Character RTS/CTS

*

Message RTS/CTS XON/XOFF Handshaking ACK/NAK Two Digit Supplements as code 39

Five Digit Supplements as code 39

Bookland 978 as code 39

43

Page 48

DEFAULT SETTINGS PARAMETER

DEFAULT

OCIA

RS232

LIGHT PEN

Bookland 977 (2 digit) Supplemental Requirement Supplements are not Required

*

Two Digit Redundancy

*

Five Digit Redundancy 100 msec to Find Supplement Configurable in 100 msec steps (MAX 800 msec)

* as code 39

Coupon Code 128

Configurable Code Lengths

7 avail.

Configurable Prefix Characters

10 avail.

Suffix Characters Prefixes for individual Code Types Editing Inter Scan-Code Delay Configurable (100 µsec steps)

800 µsec

Function/Control Key Support Minimum Element Width Configurable in 5.6 µsec steps

1 msec

Depth of Field Variable Depth of Field

*

Normal Depth of Field

*

Extended Depth of Field Long Depth of Field Ultra Close Depth of Field

44

*

IBM 46XX

KBW

USB

Page 49

DEFAULT SETTINGS Default settings for “Aux” interface The secondary scanner and the MS7320 always communicate via RS232. Data is relayed to the host via various primary interfaces. PARAMETER

DEFAULT

Aux Baud Rate

38400

Aux parity space

Aux data bits

7

Aux stop bits

2

Aux character RTS

*

OCIA

RS232

LIGHT PEN

IBM 46XX

KBW

USB

Aux message RTS Aux Ack/Nak

*

Aux Xon/Xoff

*

Aux D/E commands Aux M/O commands Aux F/L commands Aux Intercharacter Delay

1 msec

Aux Port Data Format

None (Disabled)

45

Page 50

SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS7320 scanner interfaces terminate to 10-pin modular jacks located on the back of the unit. The serial number label indicates the model number of the scanner.

Figure 31: Scanner Interface Ports

MS732x-13 OCIA Pin Function 1 Ground 2 NC 3 NC 4 RDAT A 5 RDAT A Return 6 Clock in 7 Clock out Clock in Return/ 8 Clock out Rtrn 9 + 5VDC 10 Shield Ground

46

MS732x-13 IBM 46xx Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 DT R 7 IBM B- (D-) 8

IBM A+ (D+)

9 + 5V IN 10 NC