Page 21

AUDIBLE INDICATORS When the MS7320 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, use the Multi-Function Button or refer to the MetroSelect Configuration Guide. One Beep When the scanner first receives power, the green LED will turn on, the red LED will flash and the scanner will beep once. The red LED will remain on for the duration of the beep. The scanner is now ready to scan. When the scanner successfully reads a bar code, the red LED will flash and the scanner will beep once (if configured to do so). If the scanner does not beep once and the red light does not flash, then the bar code has not been successfully read. Razzberry Tone This is a failure indicator. Refer to failure modes on page 19. Three Beeps - during operation When placing the scanner in program mode, the red LED will flash while the scanner simultaneously beeps three times. The red and green LEDs will continue to flash until the unit exits program mode. Upon exiting program mode, the scanner will beep three times and the red LED will stop flashing. When configured, three beeps can also indicate a communications timeout during normal scanning mode. When using one-code-configuring, the scanner will beep three times (the current selected tone), followed by a short pause, a high tone and a low tone. This tells the user that the single configuration bar code has successfully configured the scanner. Three beeps will also occur during a manual adjustment of the beeper tone. With each short depression of the Multi-Function Button, the new tone will be heard, followed by a short pause then two more of the new current tones. Three Beeps - on power up This is a failure indicator. Refer to failure modes on page 19. 17

Page 22

VISUAL INDICATORS There is a red LED and green LED on the front of the MS7320. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner. Figure 12: LEDs

No Red or Green LED The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. Steady Green When the laser is active, the green LED is illuminated. The green LED will remain illuminated until the laser is deactivated. During the power save mode, the laser will turn on and off. During this period, the green LED remains illuminated. Steady Green and Single Red Flash When the scanner successfully reads a bar code, the red LED will flash and the scanner will beep once. If the red LED does not flash or the scanner does not beep once, then the bar code has not been successfully read. Steady Green and Steady Red After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s red LED will remain on until the data can be transmitted. Flashing Green then Flashing Red This indicates the scanner is in program mode. A razzberry tone indicates that an invalid bar code has been scanned in this mode. or If the unit is in sleep mode, each LED will flash once every 15 seconds. Steady Red, Green off This indicates the scanner may be waiting for communication from the host. 18

Page 23

FAILURE MODES

Figure 13: LEDs

Flashing Green and One Razzberry Tone This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair at an authorized service center.

Flashing Red and Green and Two Razzberry Tones This indicates the scanner has experienced a motor failure. Return the unit for repair at an authorized service center.

Continuous Razzberry Tone with both LEDs off If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an electronic failure. Return the unit for repair at an authorized service center.

Three Beeps - on power up If the scanner beeps 3 times on power up then, the nonvolatile memory that holds the scanner configuration has failed. Return the unit for repair at an authorized service center.

19

Page 24

POWER SAVE MODES AND THE MULTI-FUNCTION BUTTON The MS7320 has five configurable power save modes. Refer to the MetroSelect Configuration Guide for additional information on Power Save Modes. 1.

Blink Power Save Mode (Default): “Blinks” the laser OFF & ON after a configured period of non-use. When the scanner recognizes a bar code it will exit the Blink mode.

2.

Laser Off Power Save Mode: Turns the laser OFF after a configured period of non-use. The motor continues to spin allowing for a faster “wake” up time. Pressing the Multi-Function button will “wake” the scanner from the Laser Off power save mode (see figure 17).

3.

Laser & Motor Off Power Save Mode: Turns the laser and motor OFF after a configured period of non-use. Pressing the Multi-Function button will “wake” the scanner from the power save mode (see figure 17). This mode is the only power save mode that can be activated by the Multi-Function Button (see figure 16). This mode’s “wake up” time is slightly longer due to the motor’s need to restart.

4.

Dual Action Power Save Mode #1: “Blinks” the laser OFF & ON after a configured period of non-use turns the laser and motor OFF at thirty-minute intervals. Example: If the power save timeout is set to 15 minutes.

Last Scan

Laser starts “Blinking”

Laser & Motor turn OFF

Pressing the Multi-Function button will “wake” the scanner from the power save mode (see figure 17). 5.

Dual Action Power Save Mode #2: Turns the laser OFF after a configured period of non-use then turns the motor OFF after thirty-minute intervals. Example: If the power save timeout is set to 15 minutes.

Last Scan

Laser turns OFF

Motor turns OFF

Pressing the Multi-Function button will “wake” the scanner from the power save mode (see figure 17).

20

Page 25

POWER SAVE MODES AND THE MULTI-FUNCTION BUTTON

Figure 14: The Multi-Function Button

CHANGING THE BEEPER TONE A Short (<3 second) depression and the beeper tone will change. The new tone will be heard, followed by a short pause. Then two more of the new tones will be heard signifying the new setting has been stored in memory. The silent (no beep) tone is also selectable. Figure 15: Changing the Beeper Tone

PLACING THE UNIT IN LASER & MOTOR OFF POWER SAVE MODE Long (>3 seconds) depression The Laser & Motor Off Power Save Mode is the only power save mode that can be activated with the multi-function button. Figure 16: Laser & Motor Off Power Save Mode

WAKING THE UNIT FROM ALL POWER SAVE MODES The next button depression will awaken the scanner for normal operation. Figure 17: Normal Operation

21

Page 26

SCAN VOLUME (BASED ON 100% UPC BAR CODES)

Figure 18: Scan Area Top View (top) Side View (Bottom)

Specifications are subject to change without notice.

22

Page 27

DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH (BASED ON 100% UPC BAR CODES)

Figure 19: Depth of Field Top View

Minimum Bar Code Element Width mm mils

A B .13 .19 .26 .33 .48 5.2 7.5

C

D

E

10.4

13

19

Specifications are subject to change without notice.

23

Page 28

DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH (BASED ON 100% UPC BAR CODES)

Figure 20: Depth of Field Side View

Minimum Bar Code Element Width mm mils

A B .13 .19 .26 .33 .48 5.2 7.5

C

D

E

10.4

13

19

Specifications are subject to change without notice.

24

Page 29

FLEX STAND INSTALLATION Flex Stand (Optional), Kit Components a. Stand Base Cover ..................Qty. 1 b. Stand Base ............................Qty. 1 c. Small Flex Cover* ..................Qty. 1 d. Flex Pole*...............................Qty. 1 e. Large Flex Cover* ..................Qty. 1 f. #8 x 1.00" Wood Screw..........Qty. 4 g. ¼"-20 x ¾" Flat Head Screw ..Qty. 1 h. ¼" External Lock Washer.......Qty. 2 i.

¼" Flat Washer ..................... Qty. 1 Figure 21: Flex Stand Parts

* Flex pole length and flex cover quantities are kit dependent. Kit Number

Flex Pole Length (d.)

Flex Cover Qty. Small (c.)

Large (e.)

46-00174 3"

1

Not Applicable

46-00157 6"

1

1

46-00175 12"

2

1

Installation 1.

Drill four #39 pilot holes in the counter top for the stand base.

Figure 22: Hole Pattern

25

Page 30

FLEX STAND INSTALLATION 2.

Secure the base plate to the counter and attach the flex pole assembly. Slide the flex cover(s)* over the flex pole assembly.

Figure 23: Pole Assembly

3.

Figure 24: Cover Assembly

Remove the scanner’s cable cover if it was previously installed.

Figure 25: Cable Cover Removal

4.

Pull the tab on the scanner’s pedestal to release the lock. Slide the pedestal off the scanner.

Figure 26: Pedestal Removal

26