Page 11

INSTALLATION FOR USB INTERFACE 1.

Turn off the host system.

2.

Determine if your application requires USB Keyboard communication protocols or USB Point-of-Sale communication protocols.

3.

If you require USB Keyboard communication protocols, skip to step 4. If you require USB Point-of-Sale communication protocols set the dip switches shown in figure 4a to positions 1 and 2.

4.

Connect the PowerLink cable to the 10-pin nd USB interface jack. It is the 2 round opening from the left side of the MS7320 (see figure 4b).

5.

Connect the other end of the USB cable to the host.

Figure 4a: POS Dip Switch

Before continuing verify that the USB cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner. Plugging the scanner into the USB port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication. 6. Scan the Enable USB Defaults bar code to configure the MS7320 for USB communication. 7.

Turn on the host system.

8.

Snap on the cable cover.

Figure 4b: USB, Interface Enable USB Defaults

³

9

9

9

9

7

8

See SELV Power Source caution statement located on page 16 of this manual.

7

Page 12

INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES 1.

Turn off the host system.

2.

Connect the PowerLink cable to the 10-pin RS232/Light Pen interface jack. It is the 1st round opening from the left side of the MS7320 (see figure 5).

3.

Connect the other end of the PowerLink cable to the host. Before continuing verify that the PowerLink cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner.

4.

Connect the external power supply to the power jack on the PowerLink Cable.

5.

Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.

6.

Connect AC power to the transformer. The outlet should be near the equipment and easily accessible.

7.

Scan the appropriate bar codes on page 9 to configure the MS7320 for RS232 or Light Pen communication.

8.

Turn on the host system.

9.

Snap on the cable cover.

Figure 5: RS232 or Light Pen Interface

See SELV Power Source caution statement located on page 16 of this manual.

8

Page 13

INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES Codes needed for Step 7 on page 8.

For RS232 Communication: Recall Defaults

Scan 1st

³

9

9

9

9

9

8

Enable RS-232

Scan 2nd

³

4

1

5

5

5

4

For Light Pen Communication: Recall Defaults

Scan 1st

³

9

9

9

9

9

8

Enable Light Pen/Wand

Scan 2nd

³

4

1

5

5

2

4

9

Page 14

INSTALLATION FOR IBM 46XX INTERFACE 1.

Turn off the host system.

2.

Connect the MVC cable to the 10-pin IBM 46xx interface jack. It is the 1st round opening from the left side of the MS7320 (see figure 6).

3.

Connect the other end of the MVC cable to the host. Before continuing verify that the MVC cable is connected to the proper communication jack on the scanner. Incorrect cable connection can cause communication problems or potential damage to the scanner. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.

4.

Turn on the host system.

5. Scan the Load 46xx IBM Defaults bar code to configure the MS7320 for RS232/IBM communication. 6.

Figure 6: IBM 46xx Interface

Snap on the cable cover For additional communication options for IBM interfaces refer to the MetroSelect Configuration Guide (MLPN 00-02407).

Load 46xx IBM Defaults

³

9

9

9

9

9

See SELV Power Source caution statement located on page 16 of this manual.

10

5

Page 15

INSTALLATION OF A SECONDARY SCANNER 1.

Turn off the host system.

2.

Connect the round end of the PowerLink RS232 AUX cable [ MLPN 54-54667 ] to the RS232 jack of the auxiliary scanner (see figure 7).

3.

Connect the other end of the PowerLink RS232 AUX cable into the 1st jack from the left side of the MS7320. The Aux jack has a square opening. The following Metrologic scanners can be used in the “Aux” input of the MS7320: the MS9520, MS9540, MS6220, MS7120, MS6520, MS6720, MS7220 or another MS7320. Important: The MS7320 aux port requires the signals: transmit, receive, RTS & CTS from the auxiliary scanner.

4.

Connect the MS7320/Host PowerLink* cable to the appropriate interface jack on the back of the MS7320.

5.

Connect the other end of the MS7320/Host PowerLink cable to the Host.

6.

Connect the external power supplies for the auxiliary scanner and the MS7320 to the power jacks on the two PowerLink cables. Before continuing verify that the PowerLink cables are connected to the appropriate interface jacks on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner.

7.

Check the AC input requirements of both power supplies to make sure the voltage matches the AC outlets.

8.

Snap on the cable cover.

9.

Connect AC power to the transformers. The outlets should be near the equipment and easily accessible.

10. Configure the MS7320 for the appropriate interface configuration settings.* Continued on page 12.

* The MS7320/host cable connection is interface dependent. Refer to the installation steps provided for the type of interface (RS232, IBM 46xx, etc.) required for your application.

See SELV Power Source caution statement located on page 16 of this manual.

11

Page 16

INSTALLATION OF A SECONDARY SCANNER 11. Scan the following bar code to configure the auxiliary port on the MS7320 to accept a Metrologic scanner as the secondary scanner. The following bar codes do not apply when using an MS6720 as a secondary scanner. Contact a Metrologic representative for additional information on the MS6720. If the secondary scanner is not a Metrologic scanner refer to Section O of the MetroSelect Configuration Guide. Enable Aux Port

³

4

3

7

3

3

0

The auxiliary input port’s data format must match the main output format of the secondary scanner. 12. Scan the following bar codes, in order, to configure the secondary scanner to match the auxiliary port’s data format. 1st

2nd

Enable AUX Output

³

1

2

4

8

Secondary Scanner Data Format

1

7

3rd

Enable Comm Timeouts

³

1

1

8

4

1

2

13. Turn on the host system. 12

³

4

3

7

5

3

0

4th (Optional)

Turn OFF Secondary Scanner’s Beeper

³

3

1

8

5

0

5

Page 17 read from a scan by OCR; it may hold reading errors

INSTALLATION OF A SECONDARY SCANNER

AUX EAS RS232 OCIA 7320-13 IBM

AUX EAS RS232 KBWEDGE 7320-37 LIGHT PEN uss

Figure 7: Connector Orientation (Top) Auxiliary Scanner Setup (Bottom)

* The MS7320/host cable connection is interface dependent.

Refer to installation steps provided for the type of interface required for your application.

NUVEQCCeSeCeeeeeerereutee? TOTTI)

>

Connect to the Secondary Scanner

13

Page 18

SCANNER PARTS

Figure 8: Scanner Parts

Output Window (Laser Aperture) Speaker Replaceable Window Face Plate Red LED (Top LED) Green LED (Bottom LED) Multi-Function Button (see page 21) Cable Connection and Dip Switch Area Cable Cover Pedestal Base/Stand Foot

MAINTENANCE Smudges and dirt on the unit’s window can interfere with the unit’s performance. If the glass window requires cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, nonabrasive cleaning cloth then gently wipe the window clean. If the red window requires cleaning use mild soap and water with a lint free, non-abrasive cleaning cloth then gently wipe the window clean. If the unit’s case requires cleaning, use a mild cleaning agent that does not contain strong oxidizing chemicals. Strong cleaning agents may discolor or damage the unit’s exterior. 14

Page 19

CABLE COVER INSTALLATION AND REMOVAL Figure 9: Installing the Cable Cover (left). Removing the Cable Cover (bottom right).

FACE PLATE REMOVAL

Figure 10: Face Plate Removal

15

Page 20

SCANNER LABELS The MS7320 has 2 labels on the back of the unit. These labels contain the model number, date of manufacture, serial number, and caution information. An additional caution label is located under the window faceplate and a label noting the jack interfaces is located under the connector cover. The following are examples of these labels. Figure 11: Scanner Labels

To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source.

16