The text of a manual · part 1 of 7
MS7320 InVista Series Installation and User's Guide, pages 1 to 10
Pages 1 to 10 of 64: MS7320 InVista®; Manual Date Code
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS-7320
Page 1
Metrologic
We really work for you.™
METROLOGIC INSTRUMENTS, INC.
MS7320 InVista® Series Installation and User’s Guide
Page 2
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc. or their respective companies.
Page 3
TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories..................................................................................... 2 Installation For OCIA Interface............................................................................................ 4 For Keyboard Wedge Interface......................................................................... 5 For Stand-Alone Keyboard Interface ................................................................ 6 For USB Interface ............................................................................................. 7 For RS232 or Light Pen Interfaces ................................................................... 8 For IBM 46xx Interface ................................................................................... 10 Of a Secondary Scanner................................................................................. 11 Scanner Parts..................................................................................................... 14 Maintenance....................................................................................................... 14 Cable Cover Installation and Removal ............................................................... 15 Face Plate Removal ........................................................................................... 15 Scanner Labels .................................................................................................. 16 Indicators Audible............................................................................................................ 17 Visual.............................................................................................................. 18 Failure Mode................................................................................................... 19 Power Save Modes and the Multi-Function Button............................................. 20 Scan Volume ...................................................................................................... 22 Depth of Field by Minimum Bar Code Element Width......................................... 23 Flex Stand Installation ........................................................................................ 25 EAS Deactivation Antenna ................................................................................. 28 Troubleshooting Guide ....................................................................................... 29 Design Specifications ......................................................................................... 34 RS232 Demonstration Program.......................................................................... 36 Applications and Protocols ................................................................................. 37 Configuration Modes .......................................................................................... 38 Upgrading the Firmware ..................................................................................... 39 ii
Page 4
TABLE OF CONTENTS Default Settings .................................................................................................. 40 Scanner and Cable Terminations Scanner Pinout Connections .......................................................................... 46 Cable Connector Configurations (Host End)................................................... 48 Limited Warranty ................................................................................................ 50 Regulatory Compliance Safety ............................................................................................................. 51 EMC................................................................................................................ 52 Patents ............................................................................................................... 55 Index................................................................................................................... 56 Contact Information And Office Locations .......................................................... 58 iii
Page 5
INTRODUCTION The MS7320 InVista® offers an outstanding combination of features, versatility, performance, and durability. This fixed mount laser bar code scanner provides ease of use and high throughput speeds by featuring a large, dynamic, and aggressive scan volume. Firmware updates are easily loaded into Flash memory. The MS7320 is equipped with a multitude of standard features including: •
Automatic Scanning Operation
•
EAS Deactivation Antenna
•
A Configurable Depth of Field
•
Supports Multiple Interfaces Including USB and Keyboard Wedge
•
Custom Edit the Bar Code Data
•
OPOS and JPOS System Compatible
•
RS232 Auxiliary Port for Adding Peripherals
•
PowerLink, User Replaceable Cables
•
Field Replaceable Outer Window
•
Sunrise 2005 Compliant
SCANNER
INTERFACE
MS7320-13
RS232, IBM 46xx, OCIA, Aux
MS7320-37
RS232, Light Pen, Keyboard Wedge, Stand-Alone Keyboard, USB, Aux
1
Page 6
SCANNER AND ACCESSORIES B ASIC K IT Part #
Description
MS7320 InVista
Series Scanner
00-02407 MetroSelect
®
Configuration Guide
00-02896
MS7320 InVista Series Installation and User’s Guide
52-52511
24" EAS Cable
Guides also available for download at www.metrologic.com.
O PTIONAL A CCESSORIES Part # 59-59xxx*
Description Straight PowerLink Cable with built in power jack. 2.1 m (7') cord with short strain relief xxx* specifies connection to the host. Contact a customer service representative for additional information.
**
2
59-59002
Keyboard Wedge PowerLink Cable with Adapter Cable
MVC**
Metrologic Voltage Converter Cable, ±12VDC to +5.2VDC
Contact a Metrologic Customer Service representative for additional information on Metrologic’s MVC cable series and the host connections available. 59-59020
Stand Alone Keyboard Wedge PowerLink Cable
59-59165
USB PowerLink Cable (Type A)
54-54667
RS232 AUX PowerLink Cable
Page 7
SCANNER AND ACCESSORIES O PTIONAL A CCESSORIES Part #
Description
AC to DC Power Transformer - Regulated 5.2V@ 1A output 46-46759
120V United States
46-46616
220V – 240V Continental European
46-46615
220V – 240V United Kingdom
46-46984
220V – 240V China
46-46985
220V – 240V Australia
46-00174
3" Flex Stand
46-00157
6" Flex Stand
46-00175
12" Flex Stand
R EPLACEMENT P ARTS Part #
Description
46-46925
Standard Red Window Face Plate
46-46852
Pedestal Base For use with 46-00174, 46-00175, and 46-00157 flex stands.
Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.
3
Page 8
INSTALLATION FOR OCIA INTERFACE 1.
Turn off the host system.
2.
Connect the MVC cable to the 10-pin OCIA interface jack. It is the 2nd round opening from the left side of the MS7320 (see figure 1).
3.
Connect the other end of the MVC cable to the host. Before continuing verify that the MVC cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration settings are also required for proper communication.
4.
Turn on the host system.
Figure 1: OCIA, Interface
5. Scan the Load OCIA Defaults bar code to configure the MS7320 for OCIA communication. 6.
Load OCIA Defaults
Snap on the cable cover. ³
9
9
9
9
9
For additional communication options for OCIA interfaces refer to the MetroSelect Configuration Guide (MLPN 00-02407).
See SELV Power Source caution statement located on page 16 of this manual.
4
3
Page 9
INSTALLATION FOR KEYBOARD WEDGE INTERFACE 1.
Turn off the host system.
2.
Disconnect the keyboard from the host.
3.
Connect the PowerLink cable to the 10-pin nd KBW interface jack. It is the 2 round opening from the left side of the MS7320 (see figure 2).
4.
Connect the “Y” end of the PowerLink cable to the keyboard and the keyboard port on the host. If necessary use the male/female adapter cable supplied with the scanner for proper connections. Before continuing verify that the PowerLink cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner.
5.
Connect the external power supply to the power jack on the PowerLink cable.
6.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.
7.
Connect AC power to the transformer. The outlet should be near the equipment and easily accessible.
Figure 2: Keyboard Wedge Interfaces
8. Scan the Load Keyboard Wedge Defaults bar code to configure the MS7320 for Keyboard Wedge communication. 9.
Load Keyboard Wedge Defaults
Turn on the host system.
10. Snap on the cable cover.
³
9
9
9
9
9
4
See SELV Power Source caution statement located on page 16 of this manual.
5
Page 10
INSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE 1.
Turn off the host system.
2.
Disconnect the keyboard from the host.
3.
Connect the PowerLink cable to the 10-pin Stand-Alone Keyboard interface jack. It is the 2nd round opening from the left side of the MS7320 (see figure 3).
4.
Connect the other end of the PowerLink cable to the keyboard port on the host. Before continuing verify that the PowerLink cable is connected to the appropriate interface jack on the scanner. An incorrect cable connection can cause communication problems or potential damage to the scanner.
5.
Connect the external power supply to the power jack on the PowerLink cable.
6.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.
7.
Connect AC power to the transformer. The outlet should be near the equipment and easily accessible.
8.
Figure 3: Stand-Alone Keyboard Interface Load Keyboard Wedge Defaults
Scan 1
St
Scan the two bar codes in numbered sequence in order to configure the MS7320 for Stand-Alone Keyboard communication.
³
Note: When scanning the bar codes, cover the code not being scanned to ensure the codes are read in the proper sequence. 9.
Turn on the host system.
10. Snap on the cable cover.
9
9
9
9
4
Enable Stand-Alone Keyboard Wedge
Scan 2 nd
³
5
1
5
5
See SELV Power Source caution statement located on page 16 of this manual.
6
9
1
5
3