Page 19

AUDIBLE INDICATORS When the Voyager is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect® Single-Line Programming Guide (MLPN 00-02544) or MetroSet®2’s help files. One Beep When the scanner first receives power, the green LED will turn on, then the red LED will flash and the scanner will beep once. (The red LED will remain on for the duration of the beep.) The scanner is ready to scan. When the scanner successfully reads a bar code, the red LED will flash and the scanner beeps once (if programmed to do so). If the scanner does not beep once and the green light does not flash, then the bar code has not been successfully read. Razzberry Tone This tone is a failure indicator. Refer to “Failure Modes" page 17. Two Beeps – On Power Up When there is a Flash ROM upgrade needed, the scanner will beep twice followed by alternating flashing of the green and red LEDs. Three Beeps - During Operation When entering configuration mode, the red LED will flash while the scanner simultaneously beeps three times. The red and green LEDs will continue to flash while in this mode. Upon exiting configuration mode, the scanner will beep three times, and the LEDs will stop flashing. When configured, 3 beeps can also indicate a communications timeout during normal scanning mode. When using one-code-programming, the scanner will beep three times (the current selected tone), followed by a short pause then by a high tone and a low tone. This tells the user that the single configuration bar code has successfully configured the scanner. Three Beeps - On Power Up This is a failure indicator. Refer to “Failure Modes” on page 17.

15

Page 20

VISUAL INDICATORS The MS9540 has three LED indicators (green, red and yellow) located on the head of the scanner. The MS9520 has two LED indicators (green and red) located on the head of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner. Green, Red & Yellow (MS9540’s Only) LEDs are off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer. The scanner is stand-by mode, and CodeGate® is enabled. Present a bar code to the scanner and the green LED will turn on when the laser turns on.

Steady Yellow (MS9540’s Only) The CodeGate button is not active. If a bar code is in the scan field, the laser will turn on. The bar code will be decoded and transmitted to the host automatically.

Steady Green When the laser is active, the green LED is illuminated. The green LED will remain illuminated until the laser is deactivated. (Default Mode Only)

Steady Green and Single Red Flash When the scanner successfully reads a bar code, the red LED will flash and the scanner will beep once. If the red LED does not flash or the scanner does not beep once, then the bar code has not been successfully read. (Default Mode Only)

Steady Green and Steady Red After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s red LED will remain on until the data can be transmitted.

16

Page 21

VISUAL INDICATORS (CONTINUED) Alternating Flashing of Green and Red This indicates the scanner is program mode. A razzberry tone indicates that an invalid bar code has been scanned while in this mode. The scanner needs to have a Flash ROM upgrade if the alternating flashing of the red and green LEDs occurs during startup and is accompanied by three beeps.

Steady Red, Green off This indicates the scanner may be waiting for communication from the host.

17

Page 22

FAILURE MODES Flashing Green and one Razzberry Tone This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair to an authorized service center.

Flashing Red and Green with Two Razzberry Tones This indicates the scanner has experienced a scanning mechanism failure. Return the unit for repair to an authorized service center.

Continuous Razzberry Tone with all LEDs off If, upon power, the scanner emits a continuous razzberry tone, then the scanner has an experienced an electronic failure. Return the unit for repair to an authorized service center.

Three Beeps – on power up If the scanner beeps 3 times on power up then the nonvolatile memory (NovRAM) that holds the scanner configuration has failed. If the scanner does not respond after reprogramming, return the scanner for repair to an authorized service center.

18

Page 23

PROGRAMMING MODES The MS9500 Voyager has 3 modes of programming.

¾ Bar Codes Voyager or Voyager CG can be configured by scanning the bar codes located in the MetroSelect® Single-Line Programming Guide (MLPN 0002544). Please refer to this guide for instructions. This manual can be downloaded for FREE from Metrologic’s website (www.metrologic.com).

¾ MetroSet®2 This user-friendly Windows-based configuration program allows you to simply ‘point-and-click’ at the desired scanner options. This program can be downloaded for FREE from Metrologic’ website (www.metrologic.com), or set-up disks can be ordered by calling 1-800-ID-METRO.

¾ Serial Programming This mode of programming is ideal for OEM applications. This mode gives the end-user the ability to send a series of commands using the serial port of the host system. The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Single-Line Programming Guide (MLPN 00-02544). How does Serial Programming work? 1.

Each command sent to the scanner is the ASCII representation of each numeral in the configuration bar code. The entire numeric string is framed with an ASCII [stx] and an ASCII [etx]. EXAMPLE #1: Command for Disabling Codabar Command = [stx]100104[etx] String Sent to Scanner = 02h 31h 30h 30h 31h 30h 34h 03h (All values are hexadecimal).

2.

If the command sent to the scanner is valid, the scanner will respond with an [ack].

3.

If the command sent to the scanner in invalid, the scanner will respond with a [nak]. NOTE: If this occurs, the end-user must start over at the very beginning of the configuration sequence. Simply re-transmitting the invalid command will not work, you must start over.

19

Page 24

PROGRAMMING MODES (CONTINUED) 4.

During programming, the motor and laser turn off. YOU CANNOT SCAN A BAR CODE WHILE IN SERIAL PROGRAM MODE.

5.

There is a 20 second window between commands. If a 20 second timeout occurs, the scanner will send a [nak] and you must start over.

6.

To enter serial program mode, send the following command [stx]999999[etx].

7.

To exit serial program mode, send the following command [stx]999999[etx], the scanner will respond with an [ack] followed by 3 beeps.

8.

This mode uses the current Baud Rate, Parity, Stop Bits and Data Bits settings that are configured in the scanner. The default settings of the scanner are 9600, Space, 2, 7 respectively. If a command is sent to the scanner to change any of these settings, the change will NOT take effect until after serial program mode is exited. EXAMPLE #2: The following example will set the scanner to the factory default settings, Disable Scanning of Code 128 bar codes, change the beeper tone, and add a “G” as a programmable prefix.

FEATURE

HOST COMMAND

ASCII REPRESENTATION

SCANNER RESPONSE

Enter Program Mode [stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h [ack] or 06h

Load Defaults

[stx]999998[etx]

02h 39h 39h 39h 39h 39h 38h 03h [ack] or 06h

Disable Code 128

[stx]100113[etx]

02h 31h 30h 30h 31h 31h 33h 03h [ack] or 06h

Alternate Tone 1

[stx]318565[etx]

02h 33h 31h 38h 35h 36h 35h 03h [ack] or 06h

Prog. Prefix #1

[stx]903500[etx]

02h 39h 30h 33h 35h 30h 30h 03h [ack] or 06h

Code Byte 0

[stx]0[etx]

02h 30h 03h

[ack] or 06h

Code Byte 7

[stx]7[etx]

02h 37h 03h

[ack] or 06h

Code Byte 1

[stx]1[etx]

02h 31h 03h

[ack] or 06h

Exit Program Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h [ack] or 06h

The scanner will beep three times!

The commands sent to the scanner do not include the small superscripted ‘3’ that you see in front of each bar code string in the MetroSelect manual. THE ‘3’ SHOULD NOT BE SENT, IT IS A CODE TYPE DESIGNATION ONLY! As you will note for commands requiring additional bar codes to be scanned (such as prefixes, suffixes, timeouts, etc.), simply send the code bytes in the same order that you would normally scan the bar codes.

20

Page 25

PROGRAMMING MODES (CONTINUED) EXAMPLE #3: The following example shows the events that occur when an invalid bar code is sent. This sample will load the factory default settings and then set the baud rate to 19200. HOST

SCANNER

COMMAND

ASCII REPRESENTATION

Enter Program Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h [ack] or 06h

Load Defaults

[stx]99999:[etx]

02h 39h 39h 39h 39h 39h 3Ah 03h [nak] or 15h

FEATURE

RESPONSE

Invalid command was sent, you must start over! Enter Program Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h [ack] or 06h

Load Defaults

[stx]999998[etx]

02h 39h 39h 39h 39h 39h 39h 03h [ack] or 06h

19200 Baud Rate

[stx]415870[etx]

02h 34h 31h 35h 38h 37h 30h 03h [ack] or 06h

Exit Program Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h [ack] or 06h

The scanner will beep three times!

This example illustrates two important points. First, if an invalid command is sent from the host, the scanner responds with a [nak] and the end-user must start over from the beginning. Second, if a command is sent to change the Baud Rate, the new baud rate does not take effect until after the end-user exits program mode.

ABBREVIATED ASCII TABLE Character

Hex Value

Decimal Value

[STX]

02h

2

[ETX]

03h

3

[ACK]

06h

6

[NAK]

15h

21

0

30h

48

1

31h

49

2

32h

50

3

33h

51

4

34h

52

5

35h

53

6

36h

54

7

37h

55

8

38h

56

9

39h

57

21

Page 26

UPGRADING THE FLASH ROM FIRMWARE The Meteor program is a functional component of Metrologic’s new line of Flashbased scanners. This program allows the user of a Metrologic scanner to quickly upgrade to a new or custom version of software. It requires the use of a personal computer running under Windows 95 or greater and the use of a communication port. The user merely connects the scanner to a communications port of the PC, launches the Meteor program, and blasts off to new software upgrades. Each MS9500, regardless of the version number or communication protocol, can be upgraded. In other words, all RS232 (-41), keyboard wedge (-47), light pen (-41), laser emulation (-00), OCIA (-9) and IBM 468X/469X (-11) units can be upgraded. To upgrade all units, a power supply and PowerLink cable (MLPN 54-54012) are required. The upgrades and custom software versions will be supplied by Metrologic in files called Motorola S-record files. These files contain all the information needed to upgrade the scanner. Simply add this file to the working directory or retrieve from its current location. The program guides the user with its simplistic one click approach. The user must first select the file; once selected and verified, the file is ready to be used in the upgrade. Press the button to upgrade the scanner, the unit will go into a “flash mode” – both the green and red LEDs will be on. The user can follow the progress of the upgrade by watching the screen for details. When the upgrade is complete, the scanner will respond with its normal one beep on power up. If two beeps occur, the scanner did not upgrade properly. (Contact Metrologic for additional details).

22

Page 27

LABELS Each scanner has a label on the back of the unit. This label has the model number, date of manufacture, serial number, CE and caution information. The following is an example of this label: EVITER TOUTE EXPOSITION-Lumiere laser emis par cette overture AVOID EXPOSURE –Laser light is emitted from this aperture

Patent Information-See Manual FCC and ICES-003 Information-See Manual Warranty VOID if case opened. Contains no user serviceable components. Complies with 21CFR 1040.10 & 1040.11 NACH EN60825-1:1994/A11:1996 5V

MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. 2.

Spray glass cleaner onto lint free, non-abrasive cleaning cloth. Gently wipe the scanner window.