Page 10
INSTALLING THE SCANNER TO THE HOST SYSTEM KEYBOARD WEDGE MS9520-47 AND MS9540-47 1.
Turn off the PC.
2.
Connect the 10-pin RJ45 male connector into the jack on the Voyager or the VoyagerCG. You will hear a ‘click’ when the connection is made.
3.
Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable. If the scanner is receiving power from the host system, skip to step #5.
4.
Make sure the AC input requirements of the power supply match the AC outlet. Connect the power supply into an AC outlet. The outlet should be near the equipment and easily accessible.
5.
Disconnect the keyboard from the PC.
6.
The PowerLink cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other. Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC.
7.
Connect to the PowerLink cable to the keyboard and the keyboard port on the PC.
8.
Power up the PC. Powering the MS9520-47/MS9540-47 directly from the computer can sometimes cause interference with the operation of the scanner or the computer. Not all computers supply the same current through the keyboard port, explaining why a scanner would work on one computer and not another. Contact a Metrologic Customer Service Representative if you require an external power supply. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
6
Page 11
INSTALLING THE SCANNER TO THE HOST SYSTEM STAND ALONE KEYBOARD 1.
Turn off the host system.
2.
Connect the 10-pin RJ45 male connector into the jack on the Voyager or VoyagerCG. You will hear a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5.
3.
Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable.
4.
Make sure the AC input requirements of the power supply match the AC outlet. Connect the power supply into an AC outlet. The outlet should be near the equipment and easily accessible.
5.
Connect the PowerLink cable to the keyboard port on the host system.
6.
Turn on the host system.
Powering the MS9520-47/MS9540-47 directly from the computer can sometimes cause interference with the operation of the scanner or the computer. Not all computers supply the same current through the keyboard port, explaining why a scanner would work on one computer and not another. Contact a Metrologic Customer Service Representative if you require an external power supply.
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
7
Page 12
INSTALLING THE SCANNER TO THE HOST SYSTEM INSTALLATION NOTES FOR USB INTERFACE Metrologic’s MX009 USB cable is a device that converts serial RS232 formatted data to either USB Keyboard or USB Point-of Sale communication protocol. Please refer to the MX009 USB Converter Cable Programming Guide (MLPN 00-02574A) supplied with your MX009 cable for detailed installation and programming guidelines.
DISCONNECTING THE POWERLINK CABLE FROM THE SCANNER Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disconnected from the PowerLink cable.
o& p q n 1.
Locate the small ‘pin-hole’ on the top of the unit near the bottom of the Voyager logo.
2.
Bend an ordinary paperclip into the shape shown above.
3.
Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’.
4.
You will here a faint ‘click’. Pull gently on the strain-relief of the PowerLink cable and it will slide out of the scanner.
8
Page 13
HOW TO USE CODEGATE® –MS9540 SERIES ONLY 1
• Auto trigger activates the laser
2
• Place the laser line on the bar code
3
• Press the CodeGate button to transmit the data
TWO MODES OF OPERATION
• Auto-trigger while in the stand • Bar code is automatically decoded and transmitted
• CodeGate activates when removed from the stand • Bar code data is transmitted when the CodeGate button is pressed
9
Page 14
STAND KITS c.
Free Standing Kits #46-46128 Contains:
a.
a. Stand (MLPN 36-00454) ................................ Qty 1 b. Apron (MLPN 50-50440) ................................ Qty 1 c. Screw, M3 x 6 mm (MLPN 18-18670)............ Qty 2 d. Washer, #5 x .5 OD (MLPN 18-18671).......... Qty 2 e. Stand Anchor (MLPN 50-50449).................... Qty 1 f. M3 x 20 mm Set Screw (MLPN 18-18672) .... Qty 1 a.
This kit, used in conjunction with the stand kit (#46-46128), can be used to bolt/hard mount the MS9500 to the countertop. Contains:
Optional Wall Mount Hanger Accessory Kit #46-46433 Contains: a. Screw #8 Round Head (MLPN 18-18057) ..... Qty.2 b. Wall Mount Hanger (MLPN 18-18057)........... Qty.1
Optional Wall Mount Hanger Kit #46-46508 Contains: a. Wall Mount Hanger ( MLPN 36-00611 ) ....... Qty. 1 b. Wall Mount Base (MLPN 36-00812) ........... Qty. 1 c. 4.8 x 13 mm, Self Tapping Screw ............. Qty. 2 (MLPN 18-18233) d. Double-Sided Adhesive Tape ..................... Qty. 1 (MLPN 36-00821) e. #8 Wood Screw (MLPN 18-18057) .............. Qty. 2
10 e. f.
Optional Hard Mount Accessory Kit #46-46351 a. Screw, #8 Round Head (MLPN 18-18057) .... Qty 4 b. Base (MLPN 36-36080) ................................. Qty 1 d.
b.
b..
Page 15
ASSEMBLING THE STANDS There are 2 options for assembling the stand. The first option allows the stand to be self-supporting and moved freely or placed anywhere on the countertop. The second option is used if the stand will be bolted/hard-mounted to the countertop.
Stand Option 1: Self-supported For use with kit #46-46128 Step 1
Apron
Slide the apron (MLPN 50-50440) over the stand (MLPN 36-00454).
Stand
Step 2 Apron Position the stand so it sits under the tab on the apron. Then secure Tab the apron to the stand using the M3 x 6 mm screws (MLPN 18-18670) and the #5 M3 x 6 mm washers (MLPN 18-18671) provided. Screw
Stand
#5 Washer
Stand Option 2: Hard-mounted to countertop For use with kit #46-46351 2.00 in Step 1 2.00 in
Drill four #39 holes in the countertop.
#8 Wood Screw
Step 2
Base
Secure the base (MLPN 36-36080) to the countertop with the four #8 wood screws (MLPN 18-18057) provided.
Continued on next page
11
Page 16
ASSEMBLING THE STAND (CONTINUED) Stand Option 2: Hard-mounted to countertop (continued) For use with kits #46-46128, #46-46351 and MS951 Stand Replacements
Anchor from Kit #46-46128 Base Assembly from Kit #46-46351 or MS951 Stand Base
Step 3 Screw the stand anchor (MLPN 50-50449) onto the base assembly until it sits flush.
Step 4 Remove the logo plate on the stand by gently using an exacto knife to release the plate hook.
Step 5 Position the stand over the base assembly.
Step 6 Secure the stand to the base assembly by installing and tightening the M3 set screw (MLPN 18-18672) under the logo plate as shown.
Step 7 Snap the logo plate back into place.
12
Page 17
ASSEMBLING THE STAND (CONT.) Wall Mount, Option 1: For Kit #46-46433 or Kit #46-46508
Step 1: Drill two #39 pilot holes 3.00” apart.
Step 2: Attach the Wall Mount Hanger to the wall with the two #8 wood screws provided.
Wall Mount, Option 2: Kit #46-46508
Step 1: Attach the Wall Mount Base to the Wall Mount Hanger with the two 4.8 x 13 mm self-tapping screws.
Step 2: Remove one side of the protective backing from the double-sided adhesive tape.
Step 3: Attach the tape to the back of the Wall Mount Hanger as shown.
Step 4: Remove the protective backing from the double-sided adhesive tape and apply hook to the wall.
13
Page 18
SCANNER PARTS Yellow LED* CodeGate Button* Red LED Green LED
MS9500 Top View
Output Window
Cable Connection
MS9500 Side View
* This feature is not available on the MS9520
14