Page 1
METROLOGIC INSTRUMENTS, INC.
MS9500 Voyager® Series Single-Line Hand-Held Laser Scanner Installation and User’s Guide
Page 2
Page 3
LOCATIONS CORPORATE HEADQUARTERS North America
Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683
Customer Service: 1-800-ID-METRO Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Internet: www.metrologic.com
EUROPEAN HEADQUARTERS Germany, Middle East and Africa
Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany
Tel: +49 89 89019 0 Fax: +49 89 89019 200 Email: info@europe.metrologic.com Germany Email: info@de.metrologic.com
Spain
Metrologic Eria lbérica SL Julián Camarillo 29, D-1 Edificio Diapasón 28037 Madrid
Tel: +34 913 272 400 Fax: +34 913 273 829 Email: info@es.metrologic.com
Italy
Metrologic Instruments Italia srl Via Emilia 70 40064 Ozzano dell’Emilia (BO)
Tel: +39 0 51 6511978 Fax: +39 0 51 6521337 Email: info@it.metrologic.com
France
Metrologic Eria France SA 69 Rue de la Belle Etoile ZI Paris Nord II, BP 50057 95947 – ROISSY CDG CEDEX
Tel: +33 (0) 1 48.63.78.78 Fax: +33 (0) 1 48.63.24.94 Email: info@fr.metrologic.com
United Kingdom
Metrologic Instruments UK Limited 58 Tempus Business Centre Kingsclere Road, Basingstoke Hampshire RG21 6XG
Tel: +44 (0) 1256 365900 Fax: +44 (0) 1256 365955 Email: info@uk.metrologic.com
Singapore
Metrologic Asia (Pte) Ltd No. 8 Kaki Bukit Place 4th Floor Singapore 416186
Tel: 65-6842-7155 Fax: 65-6842-7166 Email: info@sg.metrologic.com
China
Metro (Suzhou) Technologies Co., Ltd. 221 Xing Hai Street Suzhou Industrial Park Suzhou, China 215021
Tel: 86-512-62572511 Fax: 86-512-62571517 Email: info@cn.metrologic.com
Japan
Metrologic Japan Co., Ltd. Matsunoya Building, 6 Floor 3-14-8 Higashiueno Taitou-Ku, Tokyo 110-0015 Japan
Tel: 81-03-3839-8511 Fax: 81-03-3839-8519 Email: info@jp.metrologic.com
Brazil
Metrologic do Brasil Ltda. Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil
Tel: 55-11-5182-8226 Fax: 55-11-5182-8315 Email: info@br.metrologic.com
Outside Brazil
Metrologic South America Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil
Tel: 55-11-5182-7273 Fax: 55-11-5182-7198 Email: info@sa.metrologic.com
ASIA
SOUTH AMERICA
Copyright © 2002 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.
ii
Page 4
TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories..................................................................................... 2 Operation Test...................................................................................................... 4 Installing the Scanner to the Host System MS9520-00/9/11/14/41 and MS9540-00/9/11/14/41......................................... 5 Keyboard Wedge MS9520-47 and MS9540-47................................................ 6 Stand Alone Keyboard...................................................................................... 7 Installation Notes for USB Interface ................................................................. 8 Disconnection the PowerLink Cable from the Scanner ........................................ 8 How to Use CodeGate® - MS9540 Series Only.................................................... 9 Stand Kits ........................................................................................................... 10 Assembling the Stands....................................................................................... 11 Scanner Parts..................................................................................................... 14 Audible Indicators............................................................................................... 15 Visual Indicators ................................................................................................. 16 Failure Modes..................................................................................................... 18 Programming Modes .......................................................................................... 19 Upgrading the Flash ROM Firmware .................................................................. 22 Labels................................................................................................................. 23 Maintenance....................................................................................................... 23 Depth of Field ..................................................................................................... 24 IR Activation ....................................................................................................... 25 Applications and Protocols ................................................................................. 26 Trouble Shooting Guide...................................................................................... 27 RS-232 Demonstration Program ........................................................................ 31 Design Specifications ......................................................................................... 32 Default Settings .................................................................................................. 33 Scanner and Cable Terminations Scanner Pinout Connections .......................................................................... 38 Cable Connector Configurations .................................................................... 40 Limited Warranty ................................................................................................ 42 Notices ............................................................................................................... 43 Patents ............................................................................................................... 44 Index................................................................................................................... 45 iii
Page 5
INTRODUCTION The Voyager® MS9500 Series single-line hand-held scanners include both the MS9520 and MS9540. The VoyagerCG® MS9540 features Metrologic’s patented CodeGate® technology. CodeGate is an intuitive scanning system that is ideal for all scanning applications, including menu-scanning, point-of-sale, document processing, and inventory control. CodeGate works hand-in-hand with Metrologic’s patented automatic-triggering scheme. Simply present a bar code to the scanner; the high-visibility 650-nanometer laser is automatically activated allowing the user to easily select the bar code to be scanned. Press the CodeGate button and the data is transmitted to the host system. Equipped with both ‘in-stand’ and ‘out-of-stand’ operation, Voyager can be used as both a hand-held and fixed projection scanner. Voyager automatically senses when it is placed in the stand and de-activates the CodeGate button. If the advantage of CodeGate technology is unnecessary in your application, then the MS9520 is the Voyager of choice. The MS9520 is packed with all of the same features as the MS9540, with the exception of CodeGate. Metrologic has included many standard features such as: user programmable Flash ROM, PowerLink user-replaceable cables, MetroSet®2 and MetroSelect® configuration, EMI rating of Class B, data editing (parsing) capability using Bits ‘n’ Pieces®, and a 5-year limited warranty.
VOYAGER
VOYAGERCG
INTERFACE
MS9520 – 00
MS9540 – 00
Laser Emulation RS-232 Transmit/Receive
MS9520 – 9
MS9540 – 9
OCIA
MS9520 – 11
MS9540 – 11
IBM 468X/469X, RS232-TXD, RXD, RTS, CTS
MS9520 – 14
MS9540 – 14
RS232 - TXD, RXD, RTS, CTS, DTR, DSR
MS9520 – 41
MS9540 – 41
RS-232/Light Pen Emulation
MS9520 – 47
MS9540 – 47
Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive
1
Page 6
SCANNER AND ACCESSORIES BASIC KIT Part #
Description
MS9500
Voyager Series Scanner
00-02561 or 00-02544
MetroSelect Programming Guide* or MetroSelect Single-Line Programming Guide*
00-02410
® MS9500 Voyager Series Single-Line Hand Held Laser Scanner Installation and User’s Guide
* Available on the Metrologic website - www.metrologic.com OPTIONAL ACCESSORIES Part #
Description
AC to DC Power Transformer- Regulated 5.2VDC @ 650 mA output. 45-45593
120V United States
45-45591
220V-240V Continental European
45-45592
220V-240V United Kingdom
54-54xxx
PowerLink Cable with built in power jack 2.1m (7') straight cord, short strain relief
53-53xxx
PowerLink Cable with built in power jack 2.7m (9') coiled cord, long strain relief xxx specifies connection to the host. MX009-2**
MX009 USB Converter Cable
MVC**
Metrologic Voltage Converter Cable +12VDC to +5.2VDC or -12VDC to +5.2VDC
**
Contact a Metrologic customer service representative for additional information on the MVC and MX009 converter cable series and the host connections available.
Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.
2
Page 7
SCANNER AND ACCESSORIES OPTIONAL ACCESSORIES Part #
Description
54-54002
Keyboard Wedge PowerLink Cable with Adapter Cable
54-54020
Stand Alone Keyboard Wedge PowerLink Cable
46-46128
Free-Standing Stand with Accessories
46-46351
Hard Mount Accessory Kit (used with kit #46-46128)
46-46433
Wall Mount Hanger Accessory Kit
Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.
3
Page 8
OPERATIONAL TEST 1.
Connect the 10-pin RJ45 male connector into the jack on the Voyager or VoyagerCG. You will hear a ‘click’ when the connection is made.
2.
Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable.
3.
Connect the power supply into an AC outlet. Make sure the AC input requirements of the power supply match the AC outlet.
p n 4.
Optional o
When the Voyager is ready to scan, the green LED will turn on, the red LED will flash and the scanner will beep once.
q 5.
Place a bar code in front of the scanning window. The scanner will beep once and flash the red (default mode only) LED if the bar code was successfully decoded. For the MS9540, press the CodeGate® button to transmit the data. (See page 8.)
r Voyager is shipped from the factory programmed with default settings. Refer to the MetroSelect® Programming Guide or MetroSet®2’s help files for instructions on how to configure the scanner. MS9520/9540-00 Units Only All MS9520/9540-00 units leave the factory with Laser Emulation Mode enabled. If you recall defaults while re-configuring your scanner the Laser Emulation Mode will no longer be enabled. Refer to the MS9520/9540-00 Laser Emulation Mode section of the MetroSelect Single-Line Configuration Guide (MLPN 00-02544A) for information on enabling the Laser Emulation Mode. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV ( Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
4
Page 9
INSTALLING THE SCANNER TO THE HOST SYSTEM MS9520-00/9/11/14/41 AND MS9540-00/9/11/14/41 1.
Turn off the host system.
2.
Connect the 10-pin RJ45 male connector into the jack on the Voyager or VoyagerCG. You will hear a ‘click’ when the connection is made. If the scanner is receiving power from the host system, skip to step #5.
3.
Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable.
4.
Make sure the AC input requirements of the power supply match the AC outlet. Connect the power supply into an AC outlet. The outlet should be near the equipment and easily accessible.
5.
Connect the PowerLink cable to the proper port on the host system.
6.
Turn on the host system. Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. The scanner is shipped from the factory programmed with default ® settings. Please refer to the MetroSelect Programming Guide ® (MLPN 00-02544) or MetroSet 2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol. All MS9520-00/MS9540-00 scanners leave the factory with the Laser Emulation Mode enabled. If you recall defaults while re-configuring your scanner the Laser Emulation Mode will no longer be enabled. Refer to the MS9520/9540-00 Laser Emulation Mode section of the MetroSelect Single-Line Configuration Guide (MLPN 00-02544A) for information on enabling the Laser Emulation Mode. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
5