Page 28
DEPTH OF FIELD
Minimum Bar Code Element Width A
B mm
.13
.15
-
- mils
5.2
5.7
-
-
24
C
D
E
F
G
H
J
K
.19
-
.25
.33
.53
-
7.5
-
10
13
21
-
Page 29
IR ACTIVATION
2.5" [64 mm] Scan Width at Face Distance From Face __0.0" | [0 mm] Short Range IR | 6.2" [158 mm] 4, 4.0" +1.0" * | [102 mm +25.4 mm] Long Range IR 12.6" [320 mm] 11.0" +2.0", >.
Width of Scan Field
[229 mm +51 mm]
25
Page 30
APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. Scanner
Version Identifier
MS9520 MS9540
41
RS-232/Light Pen Emulation
MS9520 MS9540
47
Keyboard Wedge, Stand-Alone Keyboard and RS-232 Transmit/Receive
MS9520 MS9540
9
OCIA and RS-232 Transmit/Receive
MS9520 MS9540
11
IBM 468X/469X, RS232-TXD, RXD, RTS, CTS
MS9520 MS9540
00
Laser Emulation and RS-232 Transmit/Receive
MS9520 MS9540
14
RS232-TXD, RXD, RTS, CTS, DTR, DSR
Communication Protocol(s)
The MS9500 Series Hand-Held Laser Scanner with built-in PC Keyboard Wedge Interface is designed to be used for Keyboard emulation only. Many RS-232 programmable functions available in other Metrologic scanners are also available as keyboard wedge functions. The following are the most important selectable options specific to the keyboard wedge. Keyboard Type • • •
**AT (includes IBM® PS2 models 50, 55, 60, 80) XT IBM PS2 (includes models 30, 70, 8556) Keyboard Country Type
• • •
**USA Belgium French
• • •
German Italian Japanese
• • •
Spanish Swiss United Kingdom
**Default setting. Refer to pages 30-34 for default settings. Refer to the MetroSelect® Single-Line Programming Guide (MLPN 00-02544) or MetroSet®2’s help files for information on how to change the default settings.
26
Page 31
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. All Interfaces
MS9500 Series Troubleshooting Guide Symptoms
Possible Causes
Solution
No LEDs, beep or laser
No power is being supplied to the scanner
Check transformer, outlet and power strip. Make sure the cable is plugged into the scanner.
No LEDs, beep, or laser
No power is being supplied to the scanner from host
Some host systems cannot supply enough current to power Voyager. A power supply may be needed.
2 Beeps with alternately flashing LEDs on Power up
Possible ROM failure
Flash ROM Upgrade Required
3 Beeps on power up
Non-volatile RAM failure
Contact a Metrologic Representative, if the unit will not hold the programmed configuration.
Continuous razz tone on power up
RAM or ROM failure
Contact a Metrologic Representative, if the unit will not function.
Razz tone and green LED flash at power up
VLD failure
Contact a Metrologic Representative
Razz tone, red and green LEDs flash at power up
Scanning mechanism failure
Contact a Metrologic Representative
Unit scans, Communicates and beeps twice
Same symbol timeout set too short
Adjust same symbol timeout for a longer time.
The unit powers up, but does not scan/or beep
Beeper disabled. No tone selected
Enable beeper. Select tone. 27
Page 32
TROUBLESHOOTING GUIDE (CONTINUED) Symptoms
Possible Causes
Solution
The unit powers up, but does not scan and/or beep
Scanning a particular symbology that is not enabled
UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected.
The unit powers up, but does not scan and/or beep
The scanner has been programmed for a character length lock, or a minimum length and bar code being scanned does not satisfy the programmed criteria
Verify that the bar code that is being scanned falls into the criteria (Typical of Non-UPC/EAN codes) The scanner defaults to a minimum of 3 character bar code.
The unit scans a bar code, but locks up after the first scan red LED stays on
The scanner is configured to support some form of host handshaking but is not receiving the signal
If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.
The unit scans, but the data transmitted to the host is incorrect
The scanner’s data format does not match the host system requirements
Verify that the scanner’s data format matches that required by the host. Most sure that the scanner is connected to the proper host port.
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The print quality of the bar code is suspect
Check print mode. The type of printer could be the problem. Change print settings. i.e. change to econo mode or high speed.
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The aspect ratio of the bar code is out of tolerance
Check print mode. The type of printer could be the problem. Change print settings. i.e. change to econo mode or high speed.
28
Page 33
TROUBLESHOOTING GUIDE (CONTINUED) Symptoms
Possible Causes
Solution
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The bar code may have been printed incorrectly
Check if it is a check digit/character/or border problem.
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The scanner is not configured correctly for this type of bar code
Check if check digits are set properly.
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The minimum symbol length setting does not work with the bar code
Check if the correct minimum symbol length is set.
The unit scans the bar code but there is no data
Configuration is not correct
Make sure the scanner is configured for the appropriate mode.
Configuration is correct
Make sure that the proper PC type AT, PS2 or XT is selected. Verify correct country code and data formatting are selected. Adjust inter-character delay symptom.
Configuration is not correct
Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.
The unit scans but the data is not correct
The unit is transmitting each character twice
29
Page 34
TROUBLESHOOTING GUIDE (CONTINUED) Symptoms
Possible Causes
Solution
Alpha characters show as lower case
Computer is in Caps Lock mode
Enable Caps Lock detect setting of the scanner to detect whether the PC is operating in Caps Lock.
Everything works except for a couple of characters
These characters may not be supported by that country’s key look up table
Try operating the scanner in Alt mode.
Power-up OK and scans OK but does not communicate properly to the host
Com port at the host is not working or configured properly
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232” data.
Power-up OK and scans OK but does not communicate properly to the host
Cable not connected to the proper com port
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232” data.
Power-up OK and scans OK but does not communicate properly to the host
Cable not connected to the proper com port
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232” data.
The host is receiving data but the data does not look correct
The scanner and host may not be configured for the same interface parameters
Check that the scanner and the host are configured for the same interface parameters
Characters are being dropped
Inter-character delay needs to be added to the transmitted output
Add some inter-character delay to the transmitted output by using the MetroSelect Single-Line Programming Guide MLPN 00-02544.
30
Page 35
RS-232 DEMONSTRATION PROGRAM If an RS-232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the com port is working, and the scanner is working. If the bar code data displays on the screen while using this program, it only demonstrates that the hardware interface and scanner are working. At this point, investigate whether the application software and the scanner configuration match. If the application does not support RS-232 scanners, a software wedge program that will take RS-232 data and place it into a keyboard buffer may be needed. This program tells the PC to ignore RTS-CTS, Data Set Ready (DSR) and Data Carrier Detect (DCD) signals. If the demonstration program works and yours still does not, jumper RTS to CTS and Data Terminal Reading (DTR) to DCD and DSR on the back of your PC. 10 20 30 35 40 50 60 70 100 110 32766 32767
CLS ON ERROR GOTO 100 OPEN “COM1:9600,S,7,1,CSO,DSO,CD0,LF” AS#1 PRINT “SCAN A FEW BAR CODES” LINE INPUT #1, BARCODE$ PRINT BARCODE$ K$ = INKEY$: IF K$ = CHR$(27) THEN GOTO 32766 GOTO 40 PRINT “ERROR NO.”; ERR ;“PRESS ANY KEY TO TERMINATE.” KK$ = INKEY$: IF K$ = “”THEN GOTO 110 CLOSE: SYSTEM END
31
Page 36
DESIGN SPECIFICATIONS OPERATIONAL Light Source:
Visible Laser Diode 650 nm ± 10 nm
Laser Power:
Less than 1 mW (peak)
Depth of Scan Field:
0 mm – 203 mm (0” – 8”) for 0.330 mm (13 mil) bar code at default setting
Scan Speed:
72 scan lines per second
Scan Pattern:
Single scan line
Minimum Bar Width:
0.127 mm (5.0 mil)
InfraRed Activation:
Long Range: 0 mm – 279 mm ± 51 mm (0” – 11” ± 2”) Short Range: 0 mm – 102 mm ± 25 mm (0” – 4” ± 1”)
Decode Capability:
Autodiscriminates all standard bar codes for others call a Metrologic service representative
System Interfaces:
RS232, PC Keyboard Wedge, Stand-Alone Keyboard, OCIA, IBM 468X/469X, Light Pen Emulation, Laser Emulation, RS232 with DSR
Print Contrast:
35% minimum reflectance difference
Number Characters Read: Roll, Pitch, Yaw:
42°, 68°, 52°
Beeper Operation:
7 tones or no beep
Indicators (LED) Default Settings:
Up to 80 data characters (Maximum number will vary based on symbology & density)
Green = laser on, ready to scan; Red = good read; Yellow (MS9540 Only) = CodeGate button is inactive (on). CodeGate button is active (off)
MECHANICAL Length:
198 mm (7.8”)
Width:
Handle - 45 mm (1.8”), Head - 78 mm (3.1”)
Depth:
40 mm (1.6”)
Weight:
149 g (5.25 oz)
Input Voltage:
5VDC ± 0.25V
ELECTRICAL Power:
Operating = 0.825 W, Standby = 0.600 W
Current:
Operating = 165 mA @ 5VDC, Standby = 120 mA @ 5VDC
DC Transformers: Laser Class: EMC:
Class 2; 5.2V @ 650 mA CDRH: Class II; EN60825-1:1994/A11:1996 Class 1 FCC Class B
ENVIRONMENTAL Temperature: Humidity: Light Levels: Shock: Contaminants: Ventilation:
32
Operating = 0°C to 40° (32° to 104°F) Storage = -40°C to 60°C (-40°F to 140°F) 5% to 95% relative humidity, non-condensing Up to 4842 Lux (450 footcandles) Designed to withstand 1.5 m (5’) drops Sealed to resist airborne particulate contaminants None required