Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 5

IS6520/MS6520 Cubit Series Omnidirectional Bar Code Scanner Installation and User's Guide, pages 19 to 27

Pages 19 to 27 of 44

The original document is the PDF (880 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic IS6520

Page 19

PROGRAMMING MODES (CONTINUED) 6.

To enter serial program mode, send the following command [stx]999999[etx].

7.

To exit serial program mode, send the following command [stx]999999[etx], the scanner will respond with an [ack] and a long beep.

8.

This mode uses the current Baud Rate, Parity, Stop Bits and Data Bits settings that are configured in the scanner. The default settings of the scanner are 9600, Space, 2, 7 respectively. If a command is sent to the scanner to change any of these settings, the change will NOT take effect until after serial program mode is exited. EXAMPLE #2: The following example will set the scanner to the factory default settings, Disable Scanning of Code 128 bar codes, change the beeper tone, and add a “G” as a programmable prefix. HOST

SCANNER

FEATURE

COMMAND

ASCII REPRESENTATION

RESPONSE

Enter Program Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h

Load Defaults

[stx]999998[etx]

02h 39h 39h 39h 39h 39h 38h 03h

[ack] or 06h

Disable Code 128

[stx]100113[etx]

02h 31h 30h 30h 31h 31h 33h 03h

[ack] or 06h

Alternate Tone 1

[stx]318565[etx]

02h 33h 31h 38h 35h 36h 35h 03h

[ack] or 06h

Prog. Prefix #1

[stx]903500[etx]

02h 39h 30h 33h 35h 30h 30h 03h

[ack] or 06h

Code Byte 0

[stx]0[etx]

02h 30h 03h

[ack] or 06h

Code Byte 7

[stx]7[etx]

02h 37h 03h

[ack] or 06h

Code Byte 1

[stx]1[etx]

02h 31h 03h

[ack] or 06h

Exit Program Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h

The scanner will emit a long beep!

The commands sent to the scanner do not include the small superscripted ‘3’ that you see in front of each bar code string in the MetroSelect® manual. THE ‘3’ SHOULD NOT BE SENT, IT IS A CODE TYPE DESIGNATION ONLY! As you will note for commands requiring additional bar codes to be scanned (such as prefixes, suffixes, timeouts, etc.), simply send the code bytes in the same order that you would normally scan the bar codes.

13

Page 20

PROGRAMMING MODES (CONTINUED) EXAMPLE #3: The following example shows the events that occur when an invalid bar code is sent. This sample will load the factory default settings and then set the baud rate to 19200. HOST FEATURE

SCANNER

COMMAND

ASCII REPRESENTATION

RESPONSE

Enter Program Mode [stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h

Load Defaults

02h 39h 39h 39h 39h 39h 3Ah 03h

[nak] or 15h

[stx]99999:[etx]

Invalid command was sent, you must start over! Enter Program Mode [stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

Load Defaults

[stx]999998[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h [ack] or 06h

19200 Baud Rate

[stx]415870[etx]

02h 34h 31h 35h 38h 37h 30h 03h

[ack] or 06h

Exit Program Mode

[stx]999999[etx]

02h 39h 39h 39h 39h 39h 39h 03h

[ack] or 06h

The scanner will emit a long beep!

This example illustrates 2 important points. First, if an invalid command is sent from the host, the scanner responds with a [nak] and the end-user must start over from the beginning. Second, if a command is sent to change the Baud Rate, the new baud rate does not take effect until after the end-user exits program mode. ABREVIATED ASCII TABLE Character [STX]

14

Hex Value 02h

Decimal Value 2

[ETX]

03h

3

[ACK]

06h

6

[NAK]

15h

21

0

30h

48

1

31h

49

2

32h

50

3

33h

51

4

34h

52

5

35h

53

6

36h

54

7

37h

55

8

38h

56

9

39h

57

Page 21

LABELS Each scanner has a label on the back of the unit. This label has the model number, date of manufacture, serial number, CE and caution information. The following is an example of this label:

MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1.

Spray glass cleaner onto lint free, non-abrasive cleaning cloth.

2.

Gently wipe the scanner window.

15

Page 22

OPTIMAL LOW AND CLOSE DEPTH OF FIELD

WIDTH OF SCAN FIELD (mm) 250 123

225 200

J

105

175

95

150 125

82 H

G

100

73

DISTANCE: SCANNER FACE TO BAR CODE (mm)

75

D B

50 49 45 40

25 0

Minimum Bar Code Element Width A

B mm

-

.15

-

.17 mils

-

5.7

-

6.8

Note:

16

C

D

E

F

G

H

J

K

-

-

.25

.33

.53

-

-

-

10

13

21

-

The same depth of field is achieved when programming Cubit® for either Optimal Low Depth of Field or Close Depth of Field.

Page 23

OPTIMAL HIGH AND NORMAL DEPTH OF FIELD

WIDTH OF SCAN FIELD (mm) 250 123

225 200

105

175

95

150

J 82

H

G

100

73 68 D

B

DISTANCE: SCANNER FACE TO BAR CODE (mm)

125

75

58

50

49 45

25 0

Minimum Bar Code Element Width A

B mm

-

.15

-

.17 mils

-

5.7

-

6.8

Note:

C

D

E

F

G

H

J

K

-

-

.25

.33

.53

-

-

-

10

13

21

-

The same depth of field is achieved when programming Cubit® for either Optimal High Depth of Field or Normal Depth of Field.

17

Page 24

FAR DEPTH OF FIELD

WIDTH OF SCAN FIELD (mm) 250

J

H G

123

225

114

200

105

175

95 91

150 125

82 77 73

100

DISTANCE: SCANNER FACE TO BAR CODE (mm)

75 D B

50 49 45

25 0

Minimum Bar Code Element Width

18

A

B

C

D

E

F

G

H

J

K mm

-

.15

-

.17

-

-

.25

.33

.53

- mils

-

5.7

-

6.8

-

-

10

13

21

-

Page 25

TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms. All Interfaces

IS6520/MS6520 Series Troubleshooting Guide SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

No LEDs, beep or motor spin

No power is being supplied to the scanner

Check transformer, outlet and power strip. Make sure the cable is plugged in to the scanner

No LEDs, beep

No power is being supplied to the scanner front host

Some host system’s cannot supply enough current to power Omni-Quest. Use the power supply included with the scanner.

3 beeps on power up

Non-volatile RAM failure

Contact a Metrologic Representative, if the unit will not hold the programmed configuration

Continuous razz tone on power up

RAM or ROM failure

Contact a Metrologic Representative, if the unit will not function

Razz tone and green LED flash at power up

VLD failure

Contact a Metrologic Representative

Razz tone and both LEDs flash at power up

Scanner motor failure

Contact a Metrologic Representative

Unit scans, Communicates and beeps twice

Same symbol timeout set too short

Adjust same symbol timeout for a longer time

19

Page 26

TROUBLESHOOTING GUIDE (CONTINUED) All Interfaces

IS6520/MS6520 Series Troubleshooting Guide (continued) SYMPTOMS

POSSIBLE CAUSE(S)

The unit powers up, but does not scan and/or beep

Beeper disabled. No tone selected

Enable beeper. Select tone

The unit powers up, but does not scan and/or beep

Scanning a particular symbology that is not enabled

UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected

The unit powers up, but does not scan and/or beep

The scanner has been programmed for a character length lock, or a minimum length and bar code being scanned does not satisfy the programmed criteria

Verify that the bar code that is being scanned falls into the criteria. (Typical of NonUPC/EAN codes.) (The scanner defaults to a minimum of 4 character bar code)

The unit scans a bar code, but locks up after the first scan (red LED stays on)

The scanner is configured to support some form of host handshaking but is not receiving the signal

If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly

The unit scans, but the data transmitted to the host is incorrect

The scanner's data format does not match the host system requirements

Verify that the scanner's data format matches that required by the host. Make sure that the scanner is connected to the proper host port

20

SOLUTION

Page 27

TROUBLESHOOTING GUIDE (CONTINUED) All Interfaces

IS6520/MS6520 Series Troubleshooting Guide (continued) SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

The print quality of the bar code is suspect

Check print mode. The type of printer could be the problem. Change print settings. For example change to econo mode or high speed

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

The aspect ratio of the bar code is out of tolerance

Check print mode. The type of printer could be the problem. Change print settings, ie change to econo mode or high speed

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

The bar code may have been printed incorrectly

Check if it is a check digit, character, or border problem

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

The scanner is not configured correctly for this type of bar code

Check if check digits are set properly

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

The minimum symbol length setting does not work with the bar code

Check if the correct minimum symbol length is set

21