The text of a manual · part 3 of 5
IS6520/MS6520 Cubit Series Omnidirectional Bar Code Scanner Installation and User's Guide, pages 19 to 27
Pages 19 to 27 of 44
The original document is the PDF (880 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic IS6520
Page 19
PROGRAMMING MODES (CONTINUED) 6.
To enter serial program mode, send the following command [stx]999999[etx].
7.
To exit serial program mode, send the following command [stx]999999[etx], the scanner will respond with an [ack] and a long beep.
8.
This mode uses the current Baud Rate, Parity, Stop Bits and Data Bits settings that are configured in the scanner. The default settings of the scanner are 9600, Space, 2, 7 respectively. If a command is sent to the scanner to change any of these settings, the change will NOT take effect until after serial program mode is exited. EXAMPLE #2: The following example will set the scanner to the factory default settings, Disable Scanning of Code 128 bar codes, change the beeper tone, and add a “G” as a programmable prefix. HOST
SCANNER
FEATURE
COMMAND
ASCII REPRESENTATION
RESPONSE
Enter Program Mode
[stx]999999[etx]
02h 39h 39h 39h 39h 39h 39h 03h
[ack] or 06h
Load Defaults
[stx]999998[etx]
02h 39h 39h 39h 39h 39h 38h 03h
[ack] or 06h
Disable Code 128
[stx]100113[etx]
02h 31h 30h 30h 31h 31h 33h 03h
[ack] or 06h
Alternate Tone 1
[stx]318565[etx]
02h 33h 31h 38h 35h 36h 35h 03h
[ack] or 06h
Prog. Prefix #1
[stx]903500[etx]
02h 39h 30h 33h 35h 30h 30h 03h
[ack] or 06h
Code Byte 0
[stx]0[etx]
02h 30h 03h
[ack] or 06h
Code Byte 7
[stx]7[etx]
02h 37h 03h
[ack] or 06h
Code Byte 1
[stx]1[etx]
02h 31h 03h
[ack] or 06h
Exit Program Mode
[stx]999999[etx]
02h 39h 39h 39h 39h 39h 39h 03h
[ack] or 06h
The scanner will emit a long beep!
The commands sent to the scanner do not include the small superscripted ‘3’ that you see in front of each bar code string in the MetroSelect® manual. THE ‘3’ SHOULD NOT BE SENT, IT IS A CODE TYPE DESIGNATION ONLY! As you will note for commands requiring additional bar codes to be scanned (such as prefixes, suffixes, timeouts, etc.), simply send the code bytes in the same order that you would normally scan the bar codes.
13
Page 20
PROGRAMMING MODES (CONTINUED) EXAMPLE #3: The following example shows the events that occur when an invalid bar code is sent. This sample will load the factory default settings and then set the baud rate to 19200. HOST FEATURE
SCANNER
COMMAND
ASCII REPRESENTATION
RESPONSE
Enter Program Mode [stx]999999[etx]
02h 39h 39h 39h 39h 39h 39h 03h
[ack] or 06h
Load Defaults
02h 39h 39h 39h 39h 39h 3Ah 03h
[nak] or 15h
[stx]99999:[etx]
Invalid command was sent, you must start over! Enter Program Mode [stx]999999[etx]
02h 39h 39h 39h 39h 39h 39h 03h
Load Defaults
[stx]999998[etx]
02h 39h 39h 39h 39h 39h 39h 03h
[ack] or 06h [ack] or 06h
19200 Baud Rate
[stx]415870[etx]
02h 34h 31h 35h 38h 37h 30h 03h
[ack] or 06h
Exit Program Mode
[stx]999999[etx]
02h 39h 39h 39h 39h 39h 39h 03h
[ack] or 06h
The scanner will emit a long beep!
This example illustrates 2 important points. First, if an invalid command is sent from the host, the scanner responds with a [nak] and the end-user must start over from the beginning. Second, if a command is sent to change the Baud Rate, the new baud rate does not take effect until after the end-user exits program mode. ABREVIATED ASCII TABLE Character [STX]
14
Hex Value 02h
Decimal Value 2
[ETX]
03h
3
[ACK]
06h
6
[NAK]
15h
21
0
30h
48
1
31h
49
2
32h
50
3
33h
51
4
34h
52
5
35h
53
6
36h
54
7
37h
55
8
38h
56
9
39h
57
Page 21
LABELS Each scanner has a label on the back of the unit. This label has the model number, date of manufacture, serial number, CE and caution information. The following is an example of this label:
MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1.
Spray glass cleaner onto lint free, non-abrasive cleaning cloth.
2.
Gently wipe the scanner window.
15
Page 22
OPTIMAL LOW AND CLOSE DEPTH OF FIELD
WIDTH OF SCAN FIELD (mm) 250 123
225 200
J
105
175
95
150 125
82 H
G
100
73
DISTANCE: SCANNER FACE TO BAR CODE (mm)
75
D B
50 49 45 40
25 0
Minimum Bar Code Element Width A
B mm
-
.15
-
.17 mils
-
5.7
-
6.8
Note:
16
C
D
E
F
G
H
J
K
-
-
.25
.33
.53
-
-
-
10
13
21
-
The same depth of field is achieved when programming Cubit® for either Optimal Low Depth of Field or Close Depth of Field.
Page 23
OPTIMAL HIGH AND NORMAL DEPTH OF FIELD
WIDTH OF SCAN FIELD (mm) 250 123
225 200
105
175
95
150
J 82
H
G
100
73 68 D
B
DISTANCE: SCANNER FACE TO BAR CODE (mm)
125
75
58
50
49 45
25 0
Minimum Bar Code Element Width A
B mm
-
.15
-
.17 mils
-
5.7
-
6.8
Note:
C
D
E
F
G
H
J
K
-
-
.25
.33
.53
-
-
-
10
13
21
-
The same depth of field is achieved when programming Cubit® for either Optimal High Depth of Field or Normal Depth of Field.
17
Page 24
FAR DEPTH OF FIELD
WIDTH OF SCAN FIELD (mm) 250
J
H G
123
225
114
200
105
175
95 91
150 125
82 77 73
100
DISTANCE: SCANNER FACE TO BAR CODE (mm)
75 D B
50 49 45
25 0
Minimum Bar Code Element Width
18
A
B
C
D
E
F
G
H
J
K mm
-
.15
-
.17
-
-
.25
.33
.53
- mils
-
5.7
-
6.8
-
-
10
13
21
-
Page 25
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms. All Interfaces
IS6520/MS6520 Series Troubleshooting Guide SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
No LEDs, beep or motor spin
No power is being supplied to the scanner
Check transformer, outlet and power strip. Make sure the cable is plugged in to the scanner
No LEDs, beep
No power is being supplied to the scanner front host
Some host system’s cannot supply enough current to power Omni-Quest. Use the power supply included with the scanner.
3 beeps on power up
Non-volatile RAM failure
Contact a Metrologic Representative, if the unit will not hold the programmed configuration
Continuous razz tone on power up
RAM or ROM failure
Contact a Metrologic Representative, if the unit will not function
Razz tone and green LED flash at power up
VLD failure
Contact a Metrologic Representative
Razz tone and both LEDs flash at power up
Scanner motor failure
Contact a Metrologic Representative
Unit scans, Communicates and beeps twice
Same symbol timeout set too short
Adjust same symbol timeout for a longer time
19
Page 26
TROUBLESHOOTING GUIDE (CONTINUED) All Interfaces
IS6520/MS6520 Series Troubleshooting Guide (continued) SYMPTOMS
POSSIBLE CAUSE(S)
The unit powers up, but does not scan and/or beep
Beeper disabled. No tone selected
Enable beeper. Select tone
The unit powers up, but does not scan and/or beep
Scanning a particular symbology that is not enabled
UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected
The unit powers up, but does not scan and/or beep
The scanner has been programmed for a character length lock, or a minimum length and bar code being scanned does not satisfy the programmed criteria
Verify that the bar code that is being scanned falls into the criteria. (Typical of NonUPC/EAN codes.) (The scanner defaults to a minimum of 4 character bar code)
The unit scans a bar code, but locks up after the first scan (red LED stays on)
The scanner is configured to support some form of host handshaking but is not receiving the signal
If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly
The unit scans, but the data transmitted to the host is incorrect
The scanner's data format does not match the host system requirements
Verify that the scanner's data format matches that required by the host. Make sure that the scanner is connected to the proper host port
20
SOLUTION
Page 27
TROUBLESHOOTING GUIDE (CONTINUED) All Interfaces
IS6520/MS6520 Series Troubleshooting Guide (continued) SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The print quality of the bar code is suspect
Check print mode. The type of printer could be the problem. Change print settings. For example change to econo mode or high speed
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The aspect ratio of the bar code is out of tolerance
Check print mode. The type of printer could be the problem. Change print settings, ie change to econo mode or high speed
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The bar code may have been printed incorrectly
Check if it is a check digit, character, or border problem
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The scanner is not configured correctly for this type of bar code
Check if check digits are set properly
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The minimum symbol length setting does not work with the bar code
Check if the correct minimum symbol length is set
21