Page 46
Recall Defaults
D
F
1
Enable Italian Pharmaceutical
R
4
3
** Disable Italian Pharmaceutical
R
4
4
**Transmit Mod 43 Check Digit
M
D
When this option is selected, the scanner will transmit to the host the Modulo 43 check digit of Code 39.
3
Do Not Transmit Mod 43 Check Digit
M
D
4
Enable Full ASCII Code 39
R
1
When this option is enabled, the scanner will scan full ASCII Code 39 bar codes.
0
** Disable Full ASCII Code 39
R
1
1
Enable Reserved Feature
R
7
4
Disable Reserved Feature
R
3
3
41
Page 47
Enter/Exit Program Mode
Codabar **Enable Codabar
C
T
I
When this option is enabled, the scanner will scan Codabar bar codes. Disable Codabar
C Transmit Start/Stop
C
B
T
J
When this option is selected, the scanner will transmit Codabar’s start and stop characters before and after each bar code.
2 ** Do Not Transmit Start/Stop
C
B
1
Enable CLSI Editing
C
B
4
When this option is enabled, the scanner will perform CLSI library type editing before the information transmits to the host. This editing only works with 14 digit Codabar type labels. ** Disable CLSI Editing
C
42
B
3
Page 48
Recall Defaults
D
F
1
Interleaved 2 of 5 (ITF) When this option is enabled, the scanner will scan Interleaved 2 of 5 (ITF) bar codes.
** Enable ITF
C
T
M
Disable ITF
C
T
N
Enable ITF Check Digit
I
T
When these options are enabled, the scanner will scan ITF bar codes that have a Modulo 10 check digit.
2
** Disable ITF Check Digit
I
T
1
Transmit MOD 10 ITF
R
5
4
When the transmit option is chosen, the scanner will transmit the ITF MOD 10 check character. This feature works with the ITF check digit option. In order for this feature to work both must be enabled.
** Do Not Transmit MOD 10 ITF Check Digit
R
5
5
43
Page 49
Enter/Exit Program Mode
Interleaved 2 of 5 (ITF) Symbol Lengths Specify the number of ITF digits in the bar codes that will be scanned by scanning the appropriate bar codes. Specify a maximum of two bar code lengths. If all of the bar codes that will scan are variable lengths, program the scanner to VARIABLE LENGTH. ** Variable Length
I
0
0
2 Digits
I
0
2
4 Digits
I
0
4
6 Digits
I
0
6
8 Digits
I
0
8
10 Digits
I
1
0
12 Digits
I
44
1
2
Page 50
Recall Defaults
D
F
1
14 Digits
I
1
4
16 Digits
I
1
6
18 Digits
I
1
8
20 Digits
I
2
0
22 Digits
I
2
2
24 Digits
I
2
4
26 Digits
I
2
6
28 Digits
I
2
8
45
Page 51
Enter/Exit Program Mode
30 Digits
I
3
0
32 Digits
I
3
2
34 Digits
I
3
4
36 Digits
I
3
6
38 Digits
I
3
8
40 Digits
I
4
0
42 Digits
I
4
2
44 Digits
I
46
4
4
Page 52
Recall Defaults
D
F
1
46 Digits
I
4
6
48 Digits
I
4
8
50 Digits
I
5
0
ITF Minimum Symbol Length Test A custom minimum character length can be configured for only ITF bar codes. This leaves shorter minimum lengths for other code types possible. The scanner will not scan codes with fewer than the configured minimum of characters. To activate, first scan an ITF character lock length. Then scan RBC-enable minimum test. This feature overrides ITF character locking. Enable ITF Minimum Symbol Length Test
R
B
C
Disable ITF Minimum Symbol Length Test
R
B
D
47
Page 53
Enter/Exit Program Mode
Matrix 2 of 5 Enable Matrix 2 of 5
R
B
M
*Disable Matrix 2 of 5
R
B
N
Transmit Matrix 2 of 5 Check Digit
R
B
O
Do Not Transmit Matrix 2 of 5 Check Digit
R
B
P
Enable Hong Kong Matrix 2 of 5
R
B
U
Disable Hong Kong Matrix 2 of 5
R
48
B
V
Page 54
Recall Defaults
D
F
1
MSI - Plessey Check Digit Enable MSI - Plessey
R
0
When this option is enabled, the scanner will scan Plessey bar codes. ** Disable MSI - Plessey
2
R
0
3
**Enable MSI - Plessey Test of Check Digit
R
0
4
When this option is enabled, the scanner will check the Plessey bar code for a proper check digit. Disable MSI - Plessey Test of Check Digit
R
0
5
**Enable Plessey Mod 10 Check Digit
R
0
6
When this option is enabled, the scanner will scan Plessey bar codes that have a single Modulo 10 check digit.
Plessey Mod 10/10 Check Digit
R
0
7
When this option is selected, the scanner will scan Plessey bar codes that have a double Modulo 10 check digit.
49