The text of a manual · part 7 of 9
IS4120 ScanQuest Laser Scan Engine Programming Guide, pages 55 to 63
Pages 55 to 63 of 81
The original document is the PDF (241 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic IS4120
Page 55
Enter/Exit Program Mode
**Transmit Plessey Check Digits
R
1
When this option is selected, the scanner will transmit Plessey’s check digit(s) character. This option works with the Plessey Mod 10 and/or Plessey Mod 10/10 features. Enable this option and one or both of the Plessey Mod options in order for this feature to work.
2
Do Not Transmit Plessey Check Digits
R
1
3
UK Plessey Options Enable UK Plessey
R
7
When this option is enabled, the scanner will scan UK Plessey bar codes.
7
** Disable UK Plessey
R
7
8
Transmit UK Plessey Check Digit(s)
R
8
When this option is selected, the scanner will transmit Plessey’s check digit(s) character.
1
** Do Not Transmit UK Plessey Check Digit(s)
R
50
8
2
Page 56
Recall Defaults
D Enable UK Plessey Special Format
R
7
F
1
When this option is enabled, the scanner will output the data in the special format required by some UK libraries.
9
** Disable UK Plessey Special Format
R
8
0
Enable A to X Conversion (UK)
R
A
Y
**Disable A to Z Conversion (UK)
R
A
Z
Test Modes Scan Count
S
M
3
Scannability
S
M
2
When scanning this option, the scanner will enter the scan count test mode. The firmware number of the scanner will also transmit to the host device. Do not enable this feature unless a Metrologic representative instructs you to do so.
When this option is enabled, the scanner will enter the scannability test mode. Do not enable this feature unless a Metrologic representative instructs to do so.
51
Page 57
Enter/Exit Program Mode
Normal Scan/Operating
S
M
1
When this option is selected, the scanner will exit from the scannability or scan count test modes.
Transmit Scanner Parameters
I
B
6
When this option is selected, the scanner will transmit (at 9600 baud) its current configuration.
Special Features The special features options are for special applications. Do not enable any of the special features options unless instructed by a Metrologic representative. Default to ScanPal Communication Parameters When this option is selected, the scanner’s
I
B
5
Transmit Code ID
L
P parameters will automatically change to the default settings of the ScanPal data collector. The IS4120 is not completely hardware compatible with the ScanPal. When this mode is selected, the scanner will transmit a code type identifier before each bar code.
6
**Do Not Transmit Code ID
L
P
5
** Disable Sanyo 635 ECR Protocol
R
52
0
0
Page 58
Recall Defaults
D
F
1
Enable Sanyo 635 ECR Protocol
R
0
1
Enable Post Software ID Characters
R
0
8
** Disable Post Software ID Characters
R
0
9
Enable “NEWCODE” Mode “A”
R
1
4
** Disable “NEWCODE” Mode “A”
R
1
5
Enable “NEWCODE” Mode “B”
R
1
6
** Disable “NEWCODE” Mode “B”
R
1
7
Enable SNI Beetle Mode
R
2
5
** Disable SNI Beetle Mode
R
2
6 53
Page 59
Enter/Exit Program Mode
BIO DATA Mode
R
2
Recall Defaults to disable. Combines DTR and Special same symbol rescan handling.
8
Golden Bountiful Formatting
R
2
9
Enable Sineko Mode
R
4
5
Enable Caps Lock Mode (for the MI951 external wedge)
R
4
6
** Disable Caps Lock Mode
R
4
Once Sineko mode is enabled, the only way to disable this feature is by scanning the Recall Defaults bar code. Enable this option when Caps Lock is used on the keyboard. Once enabled, Metrologic’s MS951 (RS-232) handheld scanner will simulate Caps Lock keyboard input when used with Metrologic’s MI951 external keyboard wedge. This mode may not work with all applications.
7
Enable French Wyse 120V PC Term
R
6
6
** Disable French Wyse 120V PC Term
R
6
7
Enable Intermec Polling Mode D (limited function ) Disable Intermec Polling Mode D (limited function )
R
A
1 R
54
A
2
Page 60
Recall Defaults
D
F
1
Enable Rochford Thompson Mode
R
A
B
Disable Rochford Thompson Mode
R
A
C
Enable RTS Counter Toggle
R
A
When enabled, the RTS output line is pulsed high for approximately 15 milliseconds following the transmission of the bar code data to the host computer.
L
Disable RTS Counter Toggle
R
A
M
Enable BEEP on BEL RS-232
R
B
The scanner will beep upon receiving an ASCII Bell character (07H) via the RS232 port.
E
Disable BEEP on BEL
R
B
F
Enable Bancomer Mode
Locks on 16, 20, 23, 28 and 30 character bar codes. R
2
7
Disable Bancomer Mode
R Enable FedEx Parsing
R
B
I
9
8
This feature should be used with 32 character ITF Lock.
**Disable FedEx Parsing
R
B
J 55
Page 61
Enter/Exit Program Mode
Enable Retransmit of Same Code
R
A
P
**Disable Retransmit of Same Code
R
A
Q
User Programmable Prefix and Suffix ID Characters User selected prefix/suffix characters can be programmed into the scanner by scanning the 3 digit decimal equivalent of the ASCII character into the appropriate character location with the RB0-RB9 bar codes. For example, scan RAT, RB0, RB0, RB7 (007 = decimal equivalent of an ASCII "BEL" character) and the scanner will transmit an ASCII "BEL" character before each bar code. For single character prefixes or suffixes always configure the "1st" position. Use the ASCII Reference Table on pages 58-62 for the decimal equivalents. 1st Programmable Prefix ID
R
A
T
2nd Programmable Prefix ID
R
A
U
1st Programmable Suffix ID
R
A
V
2nd Programmable Suffix ID
R
A
W
Clear All Programmable Prefixes and Suffixes
R 56
A
X
Page 62
Recall Defaults
D
F
1
RB0 - RB9 Bar Codes A 3 digit decimal value must be entered for the desired ID Character. RB0 - 0
R
B
0
RB1 - 1
R
B
1
RB2 - 2
R
B
2
RB3 - 3
R
B
3
RB4 - 4
R
B
4
RB5 - 5
R
B
5
RB6 - 6
R
B
6
RB7 - 7
R
B
7
RB8 - 8
R
B
8
RB9 - 9
R
B
9
57
Page 63
ASCII Reference Table HEX Value
Decimal value
Character
Control Keyboard Eqv
00
0
NUL
@
01
1
SOH
A
02
2
STX
B
03
3
ETX
C
04
4
EOT
D
05
5
ENQ
E
06
6
ACK
F
07
7
BEL
G
08
8
BS
H
09
9
HT
I
0A
10
LF
J
0B
11
VT
K
0C
12
FF
L
0D
13
CR
M
0E
14
SO
N
0F
15
SI
O
10
16
DLE
P
11
17
DC1
Q
12
18
DC2
R
13
19
DC3
S
14
20
DC4
T
15
21
NAK
U
16
22
SYN
V
17
23
ETB
W
18
24
CAN
X
19
25
EM
Y
58