The text of a manual · part 5 of 9

IS4120 ScanQuest Laser Scan Engine Programming Guide, pages 37 to 45

Pages 37 to 45 of 81

The original document is the PDF (241 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic IS4120

Page 37

Enter/Exit Program Mode

** Enable Interleaved 2 of 5

C

T

M

Disable Interleaved 2 of 5

C

T

N

Enable Matrix 2 of 5

R

B

M

*Disable Matrix 2 of 5

R

B

N

Enable Code 11

R

4

1

** Disable Code 11

R

4

2

Enable Hong Kong Matrix 2 of 5

R

B

U

Disable Hong Kong Matrix 2 of 5

R

32

B

V

Page 38

Recall Defaults

D

F

1

Enable Airline 2 of 5

R

6

4

** Disable Airline 2 of 5

R

6

5

Minimum Code Length for All Code Types The minimum number of characters can be specified in the bar code that will be scanned by scanning one of the following bar codes. For example, when the minimum is 3, the scanner will not scan bar codes that have less than 3 characters.

Minimum 1 Character

E

X

7

** Minimum 3 Characters

E

X

8

Minimum 6 Characters

E

X

9

33

Page 39

Enter/Exit Program Mode

Code Length Minimum Feature A custom minimum character length can be configured for non-UPC/EAN type bar codes. Scan RBA followed by the digits in the RB0-RB9 range (on page 57) that match the 3 digit decimal number for the minimum. (e.g. RBA, RB0, RB1, RB6 for a 16 character minimum) The scanner will not scan codes with fewer than the configured minimum of characters.

Set minimum character length

A custom character lock length can be configured for non-UPC/EAN type bar codes. Scan RBB followed by the digits in the RB0-RB9 range that match the 3 digit decimal number for the lock length. (e.g. RBB, RB0, RB1, RB2 for a 12 character lock length) The scanner will only scan bar codes with the number of characters that match the configured lock length.

Set character lock length

R

R

B

B

A

B

UPC/EAN Code UPC and EAN are typical bar code types. These enable the default settings for UPC and EAN.

** Enable UPC

C

T

A

Disable UPC

C

34

T

B

Page 40

Recall Defaults

D

F

1

** Enable EAN

C

T

C

Disable EAN

UPC-A Options

C

T

D

When this option is selected , the scanner will transmit the UPC-A number system character. Metrologic strongly discourages the disabling of this feature because duplicate numbers may result in the database when the scanner is programmed not to transmit the UPC-A number system character. **Transmit UPC-A Number Sys

L

Z

5

Do Not Transmit UPC-A Number Sys

L

Z

6

When this option is on, the scanner will transmit the UPC-A check digit. **UPC-A Check Digit On

C

K

4

UPC-A Check Digit Off

C

K

3

35

Page 41

Enter/Exit Program Mode

Convert UPC-A to EAN-13

L

Z

When this option is selected , the scanner will convert UPC-A to EAN-13 by transmitting a leading zero before the bar code.

3

** Do Not Convert UPC-A to EAN-13

L

Z

4

UPC-E Options When this option is selected, the scanner will expand UPC-E to the 12 digit equivalent UPC-A.

Expand UPC-E

E

X

1

** Do Not Expand UPC-E

E

X

2

UPC-E Check Digit On

C

K

2

When this option is on, the scanner will transmit the UPC-E check digit.

** UPC-E Check Digit Off

C

K

1

UPC-E Leading 0 On

L

Z

1

When this option is on, the scanner will output a zero before each UPC-E bar code. ** UPC-E Leading 0 Off

L

36

Z

2

Page 42

Recall Defaults

D

F

1

Disable EAN-8 Check Digit Transmission

R

3

6

** Enable EAN-8 Check Digit Transmission

R

3

7

Disable EAN-13 Check Digit Transmission

R

3

8

** Enable EAN-13 Check Digit Transmission

R

3

9

Convert EAN-8 to EAN-13

R

5

When this option is selected , the scanner will convert EAN-8 to EAN-13 by transmitting five zeroes before the bar code.

2

** Do Not Convert EAN-8 to EAN-13

R

5

3

Enable “$” Prefix ID for UPC/EAN

R

7

0

** Disable “$” Prefix ID for UPC/EAN

R

7

1

37

Page 43

Enter/Exit Program Mode

Supplemental UPC Options Enable 2 Digit Supps

S

P

1

When this option is enabled, the scanner will scan 2 digit supplementals. ** Disable 2 Digit Supps

S Enable 5 Digit Supps

S

P

7

P

2

When this option is enabled, the scanner will scan 5 digit supplementals. ** Disable 5 Digit Supps

S

P

4

Enable Bookland

S

P

5

When this option is enabled, the scanner will require that a 5-digit supplement be scanned whenever an EAN-13 code begins with 978. ** Disable Bookland

S

P

6

Supplement Required

When this option is selected, all UPC/EAN labels that are to be scanned must have a supplement. S

P

3 ** Supplement Not Required

S

38

P

8

Page 44

Recall Defaults

D

F

1

Supplemental ISBN Options These features convert Bookland bar codes to a variety of International Standard Book Number (ISBN) formats. Enable Bookland to ISBN

R

A

F

**Disable Bookland to ISBN

R

A

G

Enable Transmit ISBN CD

R

A

H

**Disable Transmit ISBN CD

R

A

I

Enable ISBN Reformatting

R

A

J

**Disable ISBN Reformatting

R

A

K

Coupon Code 128 Supplemental scanning - perform in program mode - up to 80 numeric characters is automatic. Enable Coupon Code 128 *Disable Coupon Code 128

R

A

3

R

A

4

39

Page 45

Enter/Exit Program Mode

Enable ] C1 Transmit Coupon C128

R

A

5

*Disable ] C1 Transmit Coupon C128

R

A

6

Disable Coupon 128 Group Separator

R

C

0

Enable Coupon 128 Group Separator

R

C

1

Code 39 **Enable Code 39

C

T

When this option is enabled, the scanner will scan Code 39 bar codes.

E

Disable Code 39

C

T

F

Enable Mod 43 Check Digit

M

D

1

** Disable Mod 43 Check Digit

M

40

D

2

When this option this enabled, the scanner will only scan Code 39 bar codes that have a Modulo 43 check digit.