The text of a manual · part 4 of 6
IS1650 FocusE Area Imaging Bar Code Scanner Installation and User's Guide, pages 28 to 36
Pages 28 to 36 of 52
The original document is the PDF (6.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic IS1650
Page 28
SCANNER OPERATION FAILURE MODES Long Razzberry Tone – During Power Up Failed to initialize or configure the scanner. If the scanner does not respond after reprogramming, return the scanner for repair. Short Razzberry Tone – During Scanning An invalid bar code has been scanned when in configuration.
24
Page 29
SCANNER OPERATION DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH
MINIMUM BAR CODE ELEMENT WIDTH 1D
A
B
C
D
E
F
G mm
.132
.191
.254
.330
.533
.254
.381 mils
5.2
7.5
10.4
13
21
10
15.9
Figure 17. Depth of Field by Minimum Bar Code Element Width Specifications are subject to change without notice.
25
Page 30
SCANNER OPERATION IR ACTIVATION RANGE The IS1650 has a built in object detection sensor that instantly turns on the scanner when an object is presented within the scanner’s IR activation Area.
Figure 18. IR Activation Area Specifications are subject to change without notice.
26
Page 31
MAINTENANCE DAILY MAINTENANCE Smudges and dirt on the unit's window can interfere with the unit's performance. If the window requires cleaning, use only a mild glass cleaner containing no ammonia. When cleaning the window, spray the cleaner onto a lint free, nonabrasive cleaning cloth then gently wipe the window clean. If the unit's case requires cleaning, use a mild cleaning agent that does not contain strong oxidizing chemicals. Strong cleaning agents may discolor or damage the unit's exterior.
27
Page 32
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. All Interfaces
IS1650 Series Troubleshooting Symptom / Solution Chart Symptoms
Possible Causes
Solution
No power is being supplied to the scanner.
Check transformer, outlet and power strip. Make sure the cable is plugged into the scanner.
No power is being supplied to the scanner from the host.
Some host systems cannot supply enough current to power the 1650. A power supply may be required.
The wrong communication cable has been used.
Check that the communication cable matches the unit type and scanner configuration.
There has been a scanner configuration failure.
Contact a Metrologic service representative, if the unit will not hold the saved configuration.
There has been a diagnostic failure.
Contact a Metrologic service representative, if the unit will not function.
Long Razz tone when exiting configuration mode
There was a failure saving the new configuration.
Re-try to configure the scanner. Contact a Metrologic service representative if the unit will not hold the saved configuration.
Long Razz tone
There is a scanning mechanism failure.
Contact a Metrologic service representative.
Short Razz tone in configuration mode
An invalid bar code has been scanned.
Scan a valid bar code or quit configuration mode.
No LEDs, beep or illumination
Long Razz tone on power up
28
Page 33
TROUBLESHOOTING GUIDE Symptoms
Possible Causes
Solution
The unit powers The beeper is up, but does not disabled and no tone beep when bar is selected. code is scanned.
Enable the beeper and select a tone.
The unit powers up, but does not scan and/or beep.
The bar code symbology trying to be scanned is not enabled.
UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128, Codabar and PDF are enabled by default. Verify that the type of bar code being read has been selected.
The unit powers up, but does not scan and/or beep.
The scanner is trying to scan a bar code that does not match the configured criteria.
Verify that the bar code being scanned falls into the configured criteria (i.e. character length lock or minimum bar code length settings).
The following item is only relevant for RS232 and serial emulation USB Interfaces.
The unit scans a bar code, but locks up after the first scan and the white LED stays on.
The scanner is configured to support some form of host handshaking but is not receiving the signal.
If the scanner is setup to support ACK/NAK, RTS/CTS, or XON/XOFF, verify that the host cable and host are supporting the handshaking properly.
The unit scans, but the data transmitted to the host is incorrect.
The scanner’s data format does not match the host system requirements.
Verify that the scanner’s data format matches that required by the host. Make sure that the scanner is connected to the proper host port.
29
Page 34
TROUBLESHOOTING GUIDE Symptoms
The unit beeps at some bar codes and NOT for others of the same bar code symbology.
The unit scans the bar code but there is no data.
Possible Causes
Solution
The bar code may have been printed incorrectly.
Check if it is a check digit/character/or border problem.
The scanner is not configured correctly for this type of bar code.
Check if check digits are set properly.
The minimum symbol length setting does not work with the bar code.
Check if the correct minimum symbol length is set.
The configuration is not set correctly.
Make sure the scanner is configured for the appropriate mode.
The next four items are only relevant for a Keyboard Wedge interface.
The unit scans but the data is not correct.
30
The configuration is not set correctly.
Make sure that the proper PC type AT, or PS2 is selected. Verify correct country code and data formatting are selected. Adjust inter-character delay symptom.
The scanner and host may not be configured for the same interface parameters.
Check that the scanner and the host are configured for the same interface parameters.
Page 35
TROUBLESHOOTING GUIDE Symptoms
Possible Causes
Solution
The unit is transmitting each character twice.
The configuration is not set correctly.
Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.
Alpha characters show as lower case.
The computer is in Caps Lock mode.
Enable Caps Lock detect setting of the scanner to detect if the PC is operating in Caps Lock.
Everything works except for a couple of characters.
These characters may not be supported by that country’s key look up table.
Try operating the scanner in Alt mode.
The following item is only relevant for an RS232 interface.
The com port at the host is not working or The unit powers not configured up OK and scans properly. OK but does not communicate properly with the The cable is not host. connected to the correct com port.
Characters are being dropped.
Inter-character delay needs to be added to the transmitted output.
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS232” data.
Check to make sure that the cable is connected to the correct com port.
Add some inter-character delay to the transmitted output by using the Configuration Guides (MLPN 00-02544 and 00-02281).
31
Page 36
DEFAULT SETTINGS Many functions of the scanner can be “configured” – that is, enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages. If an asterisk is not in the default column then the default setting is OFF or DISABLED. Not every interface supports every parameter. If the interface supports a parameter listed in the charts on the following pages, a check mark ( ) will appear. PARAMETER
DEFAULT
Multi-Try Trigger, Out-of-Stand Presentation Mode, In-Stand
*
Presentation Mode, Out-of-Stand
*
Continuous Trigger Single Trigger Aiming in Trigger and Continuous Modes
*
Aiming in Presentation Mode
*
Long-Range In-Stand
*
Short-Range In-Stand Long-Range Out-of-Stand
*
Short-Range Out-of-Stand UPC/EAN
*
Code 128
*
Code 93
*
Codabar
*
Interleaved 2 of 5 (ITF)
*
MOD 10 check on ITF Code 11 Code 39
*
Full ASCII Code 39 PDF Data Matrix QR Code
32
*
RS232
IBM 46XX RS485
KBW & KEYBOARD
USB