The text of a manual · part 3 of 6
IS1650 FocusE Area Imaging Bar Code Scanner Installation and User's Guide, pages 19 to 27
Pages 19 to 27 of 52
The original document is the PDF (6.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic IS1650
Page 19
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) IBM 46xx RS485 IS1650-106 1.
Turn off the host device.
2.
Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages.
3.
Connect the other end of the MVC cable to the host device.
4.
Turn on the host device.
5.
The IS1650 will start to initialize. All LEDs (yellow, white, and blue) will light for approximately two seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep three times indicating that the scanner is ready for use.
Figure 11.
Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol.
See SELV Power caution statement located on page 10 of this manual. 15
Page 20
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) Integrated USB: Low Speed IS1650-38 Full Speed IS1650-106 1.
Turn off the host device.
2.
Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages.
3.
Plug the USB type A end (locking with power or non-locking, depending upon host setup) of the USB cable into the host’s USB port.
4.
Turn on the host device.
5.
The IS1650 will start to initialize. All LEDs (yellow, white, and blue) will light for approximately two seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep three times indicating that the scanner is ready for use.
Figure 12.
As a default, the IS1650-38 leaves the factory with USB Keyboard Emulation Mode enabled. For information on configuring the IS1650-38 for USB Serial Emulation Mode, please refer to the USB section of the MetroSelect Single-Line Configuration Guide (MLPN 00-02544). Plugging the scanner into a port on the host device does not guarantee that scanned information will be communicated properly to the host device. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol.
See SELV Power caution statement located on page 10 of this manual. 16
Page 21
INSTALLATION FLEX STAND INSTALLATION (OPTIONAL) Metrologic provides two #8 wood screws for securing the stand base to the counter top. The following figure provides the pilot hole dimensions for securing the stand base.
Figure 13. Stand Base Hole Pattern (Not to Scale)
17
Page 22
INSTALLATION
FLEX STAND INSTALLATION (OPTIONAL)
Scanner Cradle /
Orient the scanner cradle so that the flexible shaft's flat surface is facing the body of the scanner cradle.
By wh" - 20 x %" Flat Head Phillips 100° Undercut, - - ))
Flexible Shaft Cover, ?>
Flat Surface
Position the flexible shaft so that the flat surface on the end is flush against the tab on the stand base.
~<t - Flexible Shaft
Stand Base
Ys" - 20 x %" Flat Head 9 - a Phillips 100° Undercut
18
Figure 14. Assembling the Stand
Page 23
SCANNER CONFIGURATION CONFIGURATION MODES The IS1650 Series scanner has three modes of configuration. •
Bar Codes The IS1650 can be configured by scanning the bar codes included in the Metrologic Single-Line Configuration Guide (MLPN 00-02544) or the Supplemental Configuration Guide (MLPN 00-02281). These manuals can be downloaded FREE of charge from Metrologic’s website (www.metrologic.com).
•
MetroSet2 This user-friendly Windows-based configuration program allows you to simply ‘point-and-click’ at the desired scanner options. This program can be downloaded FREE of charge from Metrologic’s website (www.metrologic.com) or set-up disks can be ordered by calling 1-800-ID-METRO.
•
Serial Configuration This mode of configuration is ideal for OEM applications. This mode gives the end-user the ability to send a series of commands using the serial port of the host system. The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Single-Line Configuration Guide (MLPN 00-02544).
19
Page 24
SCANNER CONFIGURATION The IS1650 FocusE is part of Metrologic's line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and Metrologic's MetroSet2 software . A personal computer running Windows 95 or greater with an available RS232 serial or USB port is also required to complete the upgrade. PowerLink Cable #54-54014 is required when using RS232 for the upgrade process. This cable can be ordered from Metrologic at 1-800-ID-METRO. Do not use the standard cable supplied with keyboard wedge or RS485 scanner interface kits. If using USB for the upgrade process, the standard USB Type A cable provided with the scanner can be used.
To upgrade the firmware in the IS1650: 1.
Plug the scanner into a serial communication port on the host system.
2.
Start the MetroSet2 software.
3.
Click on the plus sign (+) next to Industrial Scanners to expand the supported scanner list.
4.
Choose the FocusE from the list.
5.
Click on the Configure FocusE Scanner button.
6.
Choose Flash Utility from the options list located on the left side of the screen.
7.
Click on the Open File button in the Flash Utility window.
8.
Locate and open the flash upgrade file supplied by Metrologic.
9.
Select the COM port that the scanner is connected to on the host system.
10. Verify the settings listed in the Flash Utility window. 11. Click on the Flash Scanner button to begin the flash upgrade. 12. A message will appear on the screen when the upgrade is complete.
Metrologic's customer service department can be reached at 1-800-ID-METRO or 1-800-436-3876. MetroSet2 is available for download, at no additional cost, from http://www.metrologic.com/corporate/download.
20
Page 25
SCANNER OPERATION MODES OF OPERATION* Presentation Mode, Fixed-Mount or In-Stand (Default) 1.
The IR detects an object in the IR activation range and the scanner’s light output automatically starts to flash as it attempts to scan the bar code.
2.
The scanner continuously attempts to scan the bar code until either it succeeds or the bar code is removed from the scanner’s field of view.
3.
When scanner successfully reads the bar code it will beep once, the white LED will flash and the decoded data will be transmitted to the host.
Single Trigger Mode, Out-of-Stand * The IS1650 can switch into different modes of operation using the MetroSet2 Software or Area Imaging Supplemental Guide (00-02281).
1.
The IR detects an object in the IR activation range and automatically turns on linear illumination.
2.
Aim the scanner’s line of light over the bar code.
3.
Press the trigger to initiate scanning. The scanner’s light output will start to flash as it attempts to scan the bar code. If the trigger is released the scanner will stop trying to scan.
4.
When scanner successfully reads the bar code it will beep once, the white LED will flash and the decoded data will be transmitted to the host.
Figure 15. Single Trigger Mode, Out-of-Stand
* For additional configurable modes of operation, please refer to the Area Imaging Supplemental Configuration Guide (MLPN 00-02281). 21
Page 26
SCANNER OPERATION AUDIBLE INDICATORS When the IS1650 is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files. One Beep When the scanner successfully reads a bar code, it will beep once and the white LED will turn on indicating data is being transmitted. If the scanner does not beep once and the white light does not turn on, then the bar code has not been successfully read. Short Razzberry Tone This tone is a failure indicator (see Failure Modes on page 24). Long Razzberry Tone This tone is a failure indicator (see Failure Modes on page 24). Three Beeps - At Power Up When IS1650 first receives power, it will start an initialization sequence. All LEDs (yellow, white, and blue) will light for approximately two seconds then start to flash alternately. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep three times indicating that the scanner is ready for use. Three Beeps - Configuration Mode When entering configuration mode, the white LED will flash while the scanner will simultaneously beep three times. The white and blue LEDs will continue to flash while in this mode. Upon exiting configuration mode, the scanner will beep three times, and the LEDs will stop flashing. When configured, three beeps can also indicate a communications timeout during normal scanning mode. When using single-code-configuring, the scanner will beep three times: a normal tone followed by a short pause, a high tone and then a low tone. This indicates that the single configuration bar code has successfully configured the scanner.
22
Page 27
SCANNER OPERATION VISUAL INDICATORS The IS1650 has three LED indicators (yellow, white and blue) located on the top of the scanner. When the scanner is on, the flashing or constant activity of the LEDs indicates the status of the current scan and the scanner. No LEDs are Illuminated The LEDs will not illuminate if the scanner is not receiving power from the host or transformer. The scanner is in stand-by mode. Present a bar code to the scanner and the blue LED will turn on when the IR detects the object.
Figure 16.
Steady Yellow The yellow LED illuminates when the scanner is in the stand. Steady Blue The blue LED illuminates when the scanner is active and linear illumination is on or when the scanner is attempting to decode a bar code. Steady Blue and Single White Flash When the scanner successfully reads a bar code, it will beep once and the white LED will turn on indicating data is transmitting. If the scanner does not beep once and the white light does not turn on, then the bar code has not been read successfully. Steady White When the scanner successfully reads a bar code, it will beep once and the white LED will turn on indicating that data is transmitting. After a successful scan, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s white LED will remain on until the data can be transmitted. Alternating Flashing of Blue and White This indicates the scanner is in configuration mode. A short razzberry tone indicates that an invalid bar code has been scanned while in this mode. Flashing Blue The blue LED will flash if the trigger is pressed while the scanner is in the in-stand presentation mode. The blue LED will stop flashing after a brief period of time. 23