For the Metrologic IS1650
Page 10
INTRODUCTION DESIGN SPECIFICATIONS IS1650 DESIGN SPECIFICATIONS OPERATIONAL Light Source:
LED 645 nm
Pulse Duration:
1 ms to 8 ms
Maximum Output of an Osram LED: Depth of Scan Field: Field of View: Minimum Bar Width: Infrared Activation:
Decode Capability:
Maximum 85 mA emits 3,120 mlm 0 mm – 254 mm (0" – 10") for 0.330 mm (13 mil) Bar Code at Default Setting 49 mm W x 19 mm H (1.9" W x 0.8"H) at 20 mm (0.8") 264 mm x 106 mm (10.4"W x 4.2" H) at 280 mm (11.0") 0.127 mm (5.0 mil) Long Range: 0 mm – 203 mm (0" – 8") from Window Short Range: 0 mm – 101 mm (0" – 4") from Window Autodiscriminates All Standard 1-D, RSS, PDF417, microPDF, MaxiCode, Data Matrix, QR Code, UCC, EAN Composites, Postals, Aztec, *OCR (A, B, MICR) (Image Transfer) – BMP, TIFF, or JPEG output * Optional Decode Capability
System Interfaces: Print Contrast: Number Characters Read: Beeper Operation: Indicators (LED) Default Settings:
PC Keyboard Wedge, RS232 (FULL & TTL), IBM 46xx RS485, Stand Alone Keyboard, USB (Low/Full Speed) 20% Minimum Reflectance Difference Up to 80 Data Characters on 1D; 1850 Text Characters for PDF417 7 tones or no beep Blue
Unit Powered, Ready to Scan
White
Good Read
Yellow
In Stand
MECHANICAL Height:
62 mm (2.44")
Width:
80 mm (3.15")
Depth:
116 mm (4.57")
Weight:
204 g (7.2 oz.)
Termination:
10 pin modular RJ45
Specifications are subject to change without notice.
6
Page 11
INTRODUCTION DESIGN SPECIFICATIONS (CONT.) IS1650 DESIGN SPECIFICATIONS ELECTRICAL Input Voltage:
5.0VDC ± 0.25V Peak = 2 W (Typical)
Power:
Operating = 1.65 W (Typical) Idle / Standby = 800 mW (Typical) Peak = 400 mA (Typical)
Current:
Operation = 330 mA (Typical) Idle / Standby = 160 mA (Typical)
DC Transformer:
Class 2; 5.2VDC @ 1 AMP
For Regulatory Compliance information, see pages 40- 42 ENVIRONMENTAL Operating = 0°C to 40° (32° to 104°F) Temperature: Storage = -40°C to 60°C (-40°F to 140°F) Humidity: Light Levels: Shock: Contaminants: Ventilation:
0% to 95% Relative Humidity, Non-Condensing Up to 100,000 Lux (9,290 Footcandles) Designed to withstand 1.0 m (3.3 ft.) drops Sealed to resist airborne particulate contaminants None required
Specifications are subject to change without notice.
7
Page 12
BASE MODEL CHARACTERISTICS IS1650 SCANNER Components
Figure 1. Scanner Components
Item Description
8
1
Red Window
LED Aperture
2
Blue LED
See Visual Indicators (on page 23)
3
White LED
See Visual Indicators (on page 23)
4
Yellow LED
See Visual Indicators (on page 23)
5
Trigger
Initiates Bar Code Read
6
Speaker
See Audible Indicators (on page 22)
7
Cable Connection
10-pin RJ45, Female Socket, See Scanner Pinout Connections (on page 36)
8
Cable Release
See The PowerLink Cable (on page 11)
9
M3 Mounting Holes
M3 Mounting Holes for Mounting Scanner
Page 13
BASE MODEL CHARACTERISTICS IS1650 SCANNER Dimensions
Figure 2. Scanner Dimensions
Figure 3. M3 Mounting Hole Dimensions Caution: The depth of each mounting hole is 12 mm (0.5"). For fixed mount, the mounting screws should not be over-tightened or go deeper than 10 mm (0.4") passing the bottom surface of the unit. Going further may cause serious damage to the unit and void the manufacturer warranty.
9
Page 14
BASE MODEL CHARACTERISTICS IS1650 SCANNER Caution and Serial Number Labels Each scanner has a label located on the bottom of the unit, as well as text embedded into the bottom casing. This label provides the unit’s model number, date of manufacture, serial number, CE and caution information. The following figure gives an example of the label/text and their location.
Figure 4. Label Samples and Location
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950-1. To maintain compliance with standard CSA-C22.2 No. 60950-1/UL 60950-1 and norm EN/IEC 60950-1, the power source should meet applicable performance requirements for a limited power source.
10
Page 15
INSTALLATION THE POWERLINK CABLE Connecting Important:
If the PowerLink cable is not fully ‘latched’, the unit can power intermittently.
Figure 5.
Figure 6.
Disconnecting Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disconnected from the PowerLink cable.
Figure 7. Releasing the PowerLink Cable
1.
Locate the small ‘pin-hole’ on the bottom of the unit near the cable.
2.
Bend an ordinary paperclip into the shape shown above.
3.
Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’.
4.
There will be a faint ‘click’. Pull gently on the strain-relief of the PowerLink cable to remove the cable from the unit. 11
Page 16
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) RS232 IS1650-14 1.
Turn off the host device.
2.
Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages.
3.
Connect the 9-pin D-type connector of the communication cable to the proper COM port of the host device.
4.
Plug the power supply into the power jack on the PowerLink cable. Check the AC input requirements of the power supply verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.
5.
Connect the power supply transformer to an appropriate AC power outlet.
6.
The IS1650 will start to initialize. All LEDs (yellow, white, and blue) will light for approximately two seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep three times indicating that the scanner is ready for use.
7.
Turn on the host device.
Figure 8.
Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol.
See SELV Power caution statement located on page 10 of this manual. 12
Page 17
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) Keyboard Wedge IS1650-47 1.
Turn off the host device.
2.
Plug the 10-pin RJ45 male end of the PowerLink cable into 10-pin socket on the IS1650. There will be an audible click when the connector lock engages.
3.
Disconnect the keyboard from the host device.
4.
Connect the “Y” ends of the communication cable to the keyboard and keyboard port on the host device. If necessary, use the male/female adapter cable supplied with the scanner for proper connections.
5.
Plug the external power supply (required) into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.
Figure 9.
6.
Connect the power supply transformer to an appropriate AC power outlet.
7.
The IS1650 will start to initialize. All LEDs (yellow, white, and blue) will light for approximately two seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep three times indicating that the scanner is ready for use.
8.
Turn on the host device. Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol. See SELV Power caution statement located on page 10 of this manual. 13
Page 18
INSTALLATION CABLE INSTALLATION (INTERFACE SPECIFIC) Stand Alone Keyboard IS1650-47 1.
Turn off the host device.
2.
Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the IS1650. There will be an audible click when the connector lock engages.
3.
Plug the other end of the communication cable into the host’s keyboard port.
4.
Plug the external power supply (required) into the power jack on the PowerLink cable. Check the AC input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.
5.
Connect the power supply transformer to an appropriate AC power outlet.
Figure 10.
6.
The IS1650 will start to initialize. All LEDs (yellow, white, and blue) will light for approximately two seconds then start to alternately flash. When the scanner has finished initializing the LEDs will stop flashing and the unit will beep three times indicating that the scanner is ready for use.
7.
Turn on the host device.
Plugging the scanner into a port on the host device does not guarantee that scanned information will be communicated properly to the host device. The scanner is shipped from the factory configured with default settings. Please refer to the MetroSelect Single-Line Configuration Guide (MLPN 00-02544) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the scanner and host system are using the same communication protocol.
See SELV Power caution statement located on page 10 of this manual. 14