The text of a manual · part 1 of 6
IS1650 FocusE Area Imaging Bar Code Scanner Installation and User's Guide, pages 1 to 9
Pages 1 to 9 of 52: IS1650 Series Installation and User's Guide; Manual Date Code
The original document is the PDF (6.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic IS1650
Page 1
Metrologic’
We really work for you.™
METROLOGIC INSTRUMENTS, INC.
IS1650 FocusE™ Area Imaging Bar Code Scanner Installation and User’s Guide
Page 2
Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of Metrologic Instruments, Inc. or their respective companies.
Page 3
TABLE OF CONTENTS INTRODUCTION Product Overview ............................................................................................. 1 Key Product Features....................................................................................... 1 Applications and Protocols ............................................................................... 2 Scanner and Accessories................................................................................. 3 Design Specifications ....................................................................................... 6
BASE MODEL CHARACTERISTICS IS1650 Scanner................................................................................................ 8 Components.................................................................................................. 8 Dimensions ................................................................................................... 9 Caution and Serial Labels ........................................................................... 10
INSTALLATION The PowerLink Cable ..................................................................................... 11 Cable Installation (Interface Specific) ............................................................. 12 RS232 IS1650-14........................................................................................ 12 Keyboard Wedge IS1650-47 ....................................................................... 13 Stand Alone Keyboard IS1650-47 ............................................................... 14 IBM 46xx RS485 IS1650-106...................................................................... 15 Low Speed USB IS1650-38 (Integrated) ..................................................... 16 Full Speed USB IS1650-106 (Integrated).................................................... 16 Flex Stand Installation .................................................................................... 17
SCANNER CONFIGURATION Configuration Modes ...................................................................................... 19 Bar Codes ................................................................................................... 19 MetroSet2.................................................................................................... 19 Serial Configuration..................................................................................... 19 Upgrading the Firmware ................................................................................. 20
SCANNER OPERATION Modes of Operation ........................................................................................ 21 Audible Indicators........................................................................................... 22 ii
Page 4
TABLE OF CONTENTS Visual Indicators ............................................................................................. 23 Failure Modes................................................................................................. 24 Depth of Field by Minimum Bar Code Element Width .................................... 25 IR Activation Range........................................................................................ 26
MAINTENANCE Daily Maintenance.......................................................................................... 27
TROUBLESHOOTING GUIDE Troubleshooting Symptom / Solution Chart .................................................... 28
DEFAULT SETTINGS Communication Parameters ........................................................................... 32
SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections .......................................................................... 36 Cable Connector Configurations .................................................................... 38
PATENTS ...................................................................................................43 LIMITED WARRANTY...................................................................................44 INDEX .......................................................................................................45 CONTACT INFORMATION AND OFFICE LOCATIONS ........................................47 iii
Page 5
INTRODUCTION PRODUCT OVERVIEW The IS1650 is a high performance area imaging bar code scanner that utilizes a high-resolution CMOS imaging sensor for unrivaled image quality. The IS1650 is the choice of 2D imaging scanners that delivers superior performance for presentation and fixed-mount applications. The IS1650 employs Omniplanar, Inc.’s SwiftDecoder™ software, for reliable decoding of all 1D and 2D bar code symbologies. Omnidirectional scanning capabilities and an extended depth of field provides aggressive scanning of all standard 1D, RSS, PDF417, microPDF, Composite, Matrix and Postal Codes symbology types. In addition, the IS1650 scanner supports OCR (A, B, & MICR). The IS1650 provides a built-in object detection sensor (IR) that instantly turns on the scanner when an object is presented within the scanner’s field of view. Whether fixed mount or in stand, the IS1650 delivers aggressive, convenient hands-free scanner. Firmware updates are easily loaded into Flash memory.
KEY PRODUCT FEATURES The IS1650 is equipped with a multitude of standard features including: •
Automatic Scanning Operation
•
Supports Multiple Interfaces Including USB and Keyboard Wedge
•
Custom Edit the Bar Code Data
•
OPOS and JPOS System Compatible
•
User Replaceable Cables
•
Sunrise 2005 Compliant
•
RoHS Compliant
•
Supports Customer Software Plug-Ins
1
Page 6
INTRODUCTION APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. VERSION IDENTIFIER
SCANNER
IS1650 -
COMMUNICATION PROTOCOL(S)
14
RS232 (TX, RX, RTS, CTS, DTR)
38
Low Speed USB and RS232 Transmit/Receive
47
Keyboard Wedge, Stand-Alone Keyboard and RS232 Transmit/Receive
106
IBM 46xx RS485, Full Speed USB, and RS232 Transmit/Receive
The IS1650-47 with a built-in PC Keyboard Wedge Interface is designed for Keyboard emulation use only. Many RS232 configurable functions are also available as keyboard wedge functions. The following are the most important selectable options specific to the keyboard wedge. Keyboard Type • •
**AT (includes IBM® PS2 models 50, 55, 60, 80) IBM PS2 (includes models 30, 70, 8556) Keyboard Country Type
• • • • • **
2
*USA Belgian French German Hungarian
• • • • •
Italian Japanese Russian Cyrillic Slovenian Spanish
• • • •
Swiss Swedish/Finnish Turkish United Kingdom
For additional information on the IS1650’s default settings refer to pages 32-35. For information on how to change the default settings, refer to help files in MetroSet2 or the MetroSelect Single-Line Configuration Guide (MLPN 00-02544).
Page 7
INTRODUCTION SCANNER AND ACCESSORIES BASIC KIT Part #
Description
IS1650
Area Imaging Bar Code Scanner
00-02544
MetroSelect® Single-Line Configuration Guide*
00-02281
Area Imaging Supplemental Configuration Guide*
00-02287
IS1650 Series Area Imaging Bar Code Scanner Installation and User’s Guide*
* Also available for download on the Metrologic website - www.metrologic.com
OPTIONAL ACCESSORIES Part #
Description AC to DC Power Transformer Regulated 5.2VDC @ 1 AMP output.
46-00525
120V United States
46-00526
220V-240V Continental European
46-00870
220V-240V United Kingdom
46-00528
220V-240V Australia
46-00529
220V-240V China
Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.
3
Page 8
INTRODUCTION SCANNER AND ACCESSORIES OPTIONAL ACCESSORIES Part #
Description IS1650 Scanner Interface Specific Cables
59-59000-3
RS232 PowerLink Cable with Built in Power Jack, straight, black
54-54002-3
Keyboard Wedge PowerLink Cable with Adapter Cable, straight, black
54-54020-3
Stand Alone Keyboard PowerLink Cable, straight, black
59-59313-N-3
USB Power/Communication Cable, straight, black
MVC-3M106S-IB9
Metrologic Voltage Converter (MVC) Cable* ±12VDC to +5.2VDC, straight, black
* Contact a Metrologic customer service representative for additional information on the MVC cable series and the host connections available.
Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.
4
Page 9
INTRODUCTION SCANNER AND ACCESSORIES OPTIONAL ACCESSORIES Part #
Description
00-02001
IS1650 Series Stand Installation Guide
46-00710
Flex Stand, Kit Flex Stand, Kit Components a. Stand Base ...............................................................................Qty. 1 b. Flexible Shaft............................................................................Qty. 1 c. Flexible Shaft Cover ................................................................Qty. 1 d. Scanner Cradle.........................................................................Qty. 1 e. 1/4" – 20 x 1/2" Flat Head Phillips ...........................................Qty. 2 f. #8 Round Head Wood Screw ....................................................Qty. 2 Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.
5