Page 37

DEFAULT SETTINGS PARAMETER

DEFAULT

RS232

IBM 46XX RS485

KBW &

USB

KEYBOARD

Maxicode Aztec Postals Mod 43 Check on Code 39 MSI-Plessy 10/10 Check Digit MSI-Plessy Mod 10 Check Digit

*

Paraf Support ITF ITF Symbol Lengths

Variable

Symbol Length Lock

None

Beeper tone

Normal

Beep/transmit sequence

Before transmit

Communication timeout

None

Razzberry tone on timeout Three beeps on timeout Same symbol rescan timeout: 1000 msecs

*

Same symbol rescan timeout configurable in 50 msec steps (maximum of 6.35 sec.) No Same symbol timeout Infinite Same symbol timeout Inter-character delay configurable in 1 msec steps (maximum of 255 msecs)

1 msecs 10 msecs in KBW

Number of scan buffers (maximum)

8

Transmit UPC-A check digit

*

Transmit UPC-E check digit Expand UPC-E Convert UPC-A to EAN-13

33

Page 38

DEFAULT SETTINGS PARAMETER

DEFAULT

Transmit lead zero on UPC-E Transmit UPC-A number system

*

Transmit UPC-A Manufacturer ID#

*

Transmit UPC-A Item ID#

*

Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check digit on Code 39 Transmit Mod 10/ITF Transmit MSI-Plessy Parity

No

Baud Rate

9600

8 Data Bits

*

7 Data Bits Stop Bits

1

Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Carriage Return

*

Line Feed-Disabled by default in KBW

*

Tab Prefix Tab Suffix “DE” Disable Command Enable Command DTR Handshaking support RTS/CTS Handshaking Character RTS/CTS Message RTS/CTS

34

*

RS232

IBM 46XX RS485

KBW & KEYBOARD

USB

Page 39

DEFAULT SETTINGS PARAMETER

DEFAULT

RS232

IBM 46XX RS485

KBW &

USB

KEYBOARD

XON/XOFF Handshaking ACK/NAK Two Digit Supplements Five Digit Supplements Bookland 977 (2 digit) Supplemental Requirement Supplements are not Required

*

Two Digit Redundancy

*

Five digit Redundancy Coupon Code 128 † Configurable Code Lengths

7 avail

† Code Selects with configurable Code Length Locks

3 avail

Configurable Prefix characters

10 avail

Suffix characters

10 avail

Prefixes for Individual Code types Editing Function/Control Key Support

*

Omnidirectional Scanning

*

Linear Only Scanning Linear 1D / Omni 2D

† These options are mutually exclusive. One cannot be used in conjunction with the other.

35

Page 40

SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS

The IS1650 scanner interfaces terminate to a 10-pin, RJ45 Female Socket. The serial number label indicates the interface enabled when the scanner is shipped from the factory.

IS1650-14 RS232 Pin 1 2 3 4 5 6 7 8 9 10

Function Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input DTR Input Reserved Reserved +5VDC Shield Ground

IS1650-47, Keyboard Wedge & Stand-Alone Keyboard

Figure 19.

36

Pin 1 2 3 4 5 6 7 8 9 10

Function Ground RS232 Transmit Output RS232 Receive Input PC Data PC Clock KB Clock PC +5V KB Data +5VDC Shield Ground

Page 41

SCANNER AND CABLE TERMINATIONS SCANNER PINOUT CONNECTIONS

IS1650-38 Low Speed USB Pin 1 2 3 4 5 6 7 8 9 10

Function Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input USB D+ V USB USB D+5VDC Shield Ground

IS1650-106 IBM 46xx RS485 / Full Speed USB Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 IBM A+ 5 IBM B6 USB D+ 7 V USB 8 USB D9 +5VDC 10 Shield Ground

Figure 20.

37

Page 42

SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS (HOST END) “Standard” PowerLink Cable 59-59000-3, Straight Pin

Function

1

Shield Ground

2

RS232 Transmit Output

3

RS232 Receive Input

4

DTR Input/Light Pen Source

5

Power/Signal Ground

6

Reserved

7

CTS Input

8

RTS Output

9

+5VDC

9

5

6

1

9-Pin D-Type Connector

Stand Alone PowerLink Keyboard Cable 54-54020-3, Straight Pin

Function

1 2

PC Data NC

3 4 5 6

Power Ground +5VDC PC Power to KB PC Clock NC

1

2 4

3 6 5

6-Pin Male Mini-DIN Connector

USB Power/Communication Cable 59-59313-N-3, Straight

Pin

Function

1

PC +5V/V_USB

2

D-

3

D+

4

Ground

Shield Shield

38

USB Non-Locking

Page 43

SCANNER AND CABLE TERMINATIONS CABLE CONNECTOR CONFIGURATIONS (HOST END) Keyboard Wedge Cable 54-54002-3, Straight Pin 1 2 3 4 5 Pin 1 2 3 4 5 6

Function Keyboard Clock Keyboard Data No Connect Power Ground +5 VDC Function PC Data No Connect Power Ground +5 VDC PC Clock No Connect

4

2

5

1

3

5-Pin DIN, Female

1

2 4

3 6 5

6-Pin DIN, Male

Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC. Keyboard Wedge Adapter Cable Pin 1 2 3 4 5 Pin 1 2 3 4 5 6

Function PC Clock PC Data No Connect Power Ground +5 VDC Function Keyboard Data No Connect Power Ground +5 VDC Keyboard Clock No Connect

5

2

4

3

1

5-Pin DIN, Male

1

2

3

4 5 6

6-pin Mini DIN, Female

39

Page 44

REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1

LED Class 1 LED Product: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2

Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Under no circumstances should the customer attempt to service the LED scanner. Never attempt to look at the LED beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous radiation exposure. The use of optical instruments with the LED equipment will increase eye hazard.

Atención La modificación de los procedimientos, o la utilización de controles o ajustes distintos de los especificados aquí, pueden provocar una exposición de luz brillante peligrosa. Bajo ninguna circunstancia el usuario deberá realizar el mantenimiento del LED (Diodo Emisor de Luz) del lector. Ni intentar mirar al haz del LED incluso cuando este no esté operativo. Tampoco deberá abrir el lector para examinar el aparato. El hacerlo puede conllevar una exposición peligrosa a la luz del LED. El uso de instrumentos ópticos con el equipo LED puede incrementar el riesgo para la vista.

Attention L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou la LED. Ne regardez jamais directement le rayon LED, même si vous croyez que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez à un risque d’irradiation. L'emploi d'appareils optiques avec cet équipement à LED augmente le risque d'endommagement de la vision.

Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Licht emittierender Dioden strahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Licht emittierender Dioden-Scanner selbst zu warten. Sehen Sie niemals in den Licht emittierender Diodenstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät hineinzusehen. Wenn Sie dies tun, können Sie sich einer gefährlichen Licht emittierender Diodenstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung.

Attenzione L'utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale può provocare delle rischiose esposizioni radiattive. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner LED (o diodo emettitore di luce). Non guardate mai il raggio LED (d. emettitore di luce), anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l'apparecchio. Facendolo potete esporVi ad una radiazione rischiosa. L'uso di apparecchi ottici, equipaggiati con raggi LED (d. emettitori di luce), aumenta il rischio di danni alla vista.

40

Page 45

REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022

Immunity CISPR 24, EN 55024 Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Class A Devices The following is applicable when the scanner cable is greater in length than 3 meters (9.8 feet) when fully extended: Les instructions ci-dessous s’appliquent aux cables de scanner dépassant 3 métres (9.8 pieds) de long en extension maximale: Folgendes trifft zu, wenn das Scannerkabel länger als 3 Meter ist: This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense. Any unauthorized changes or modifications to this equipment could void the user’s authority to operate this device. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Notice This Class A digital apparatus complies with Canadian ICES-003.

Remarque Cet appareil numérique de classe A est conforme à la norme canadienne NMB-003.

European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Funkstöreigenschaften nach EN55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen. In diesem Fall kann vom Betreiber verlangt werden, angemessene Massnahmen durchzuführen.

Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure. Attention Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la cause d’interférences radio. Dans ce cas l’utiliseteur peut être amené à predre les mesures adéquates.

41