Page 75
Vehicle 12-80VDC Power Connection
65
How To: Connect Vehicle 12-80VDC Connection 1.
The VX5 must be turned off and the power cable must be UNPLUGGED from the VX5.
2.
While observing the fuse requirements specified above, connect the power cable as close as possible to the actual battery terminals of the vehicle. When available, always connect to unswitched terminals in vehicle fuse panel, after providing proper fusing. ATTENTION:
3.
For uninterrupted power, electrical supply connections should not be made at any point after the ignition switch of the vehicle.
Route the power cable the shortest way possible. The cable is rated for a maximum temperature of 105°C (221°F). When routing this cable it should be protected from physical damage and from surfaces that might exceed this temperature. Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate. Note: If the vehicle is equipped with a panel containing Silicon Controller Rectifiers (SCR’s), avoid routing the power cable in close proximity to these devices. Always route the cable so that it does not interfere with safe operation and maintenance of the vehicle.
Use proper electrical and mechanical fastening means for terminating the cable. Properly sized “crimp” type electrical terminals are an accepted method of termination. Please select electrical connectors sized for use with 18AWG (1mm2) conductors. Wiring color codes for LXE supplied DC input power cabling: Vehicle Supply
Wire Color
+12 - 80VDC
(DC +)
White
Return
(DC -)
Black
Vehicle Chassis
GND
Green
Figure 66 Vehicle Connection Wiring Color Codes 4.
Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals, taking care not to over tighten and pinch conductors or penetrate outer cable jacket.
E-EQ-VX5OGWW-F-ARC
VX5 User’s Guide
Page 76
66
Vehicle 12-80VDC Power Connection
How To: Connect VX5 without a UPS Battery Pack
GND
+
-
B A
C Figure 67 Direct Connection (No UPS Battery Pack)
VX5 User’s Guide
A
Vehicle Battery
B
Vehicle Power Connection Cable
C
VX5 Computer
1.
Connect the power cable to the VX5 by aligning the water-tight connector pins to the power connector; push down on the water-tight connector and twist it to fasten securely.
2.
Turn the VX5 on.
E-EQ-VX5OGWW-F-ARC
Page 77
Vehicle 12-80VDC Power Connection
67
How To: Connect VX5 to a Integrated Mount UPS Battery Pack
D
GND
+
-
B C
A
Figure 68 Integrated Mount UPS Battery Pack Connection A
Vehicle Battery
B
Vehicle Power Connection Cable
C
UPS Battery Pack
D
VX5 Computer
1.
Connect the power cable to the UPS battery pack by aligning the water-tight connector pins to the input connector (marked “From Vehicle”); push down on the water-tight connector and twist it to fasten securely.
2.
Connect the output cable (marked “To Computer”) from the UPS battery pack to the VX5 by aligning the water-tight connector to the power connector; push down on the water-tight connector and twist it to fasten securely.
3.
Turn the VX5 on.
E-EQ-VX5OGWW-F-ARC
VX5 User’s Guide
Page 78
68
Vehicle 12-80VDC Power Connection
How To: Connect VX5 to a Remotely Mounted UPS Battery Pack
D
E
GND
+
-
B A
C
Figure 69 Remote Mount UPS Battery Pack Connection A
Vehicle Battery
B
Vehicle Power Connection Cable
C
UPS Battery Pack
D
Extension Cable
E
VX5 Computer
1.
Connect the power cable to the UPS battery pack by aligning the water-tight connector pins to the input connector (marked “From Vehicle”); push down on the water-tight connector and twist it to fasten securely.
2.
Connect the output cable (marked “To Computer”) from the UPS battery pack to the extension cable by aligning the water-tight connector to the input end of the extension cable; push down on the water-tight connector and twist it to fasten securely.
3.
Route the extension cable the shortest way possible. The cable is rated for a maximum temperature of 105°C (221°F). When routing this cable it should be protected from physical damage and from surfaces that might exceed this temperature. Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate. Always route the cable so that it does not interfere with safe operation and
VX5 User’s Guide
E-EQ-VX5OGWW-F-ARC
Page 79
Vehicle 12-80VDC Power Connection
69 maintenance of the vehicle. Note: If the vehicle is equipped with a panel containing Silicon Controller Rectifiers (SCR’s), avoid routing the power cable in close proximity to these devices. 4.
Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals, taking care not to over tighten and pinch conductors or penetrate outer cable jacket.
5.
Connect the output end of the extension cable to the VX5 by aligning the water-tight connector to the power connector; push down on the water-tight connector and twist it to fasten securely.
6.
Turn the VX5 on.
E-EQ-VX5OGWW-F-ARC
VX5 User’s Guide
Page 80
70
Power Adapter Cable
Power Adapter Cable LXE offers an adapter cable (part no. 9000A077CBLPWRADPTR) to adapt certain VX1, VX2 or VX4 DC power supplies to the VX5. Please read and follow all cautions below to determine if your present power supply can be used with the VX5.
1. VX5 Connector 2. VX1/2/4 Power Supply Connector 1
2
Figure 70 Power Adapter Cable, VX1/2/4 to VX5
!
This document assumes the VX1/2/4 DC power cable, if applicable, is already properly connected to your vehicle. If this is not the case, please refer to the “VX1 User’s Guide”, “VX2 User’s Guide” or “VX4 User’s Guide” for direct vehicle connection details.
Caution:
For use only with VX1/2/4 DC power cables with yellow colored cable containing 18AWG wires.
Caution:
!
Do not use this cable with VX1/2/4 DC power cables with gray colored cable containing 22AWG wires. These power cables must be replaced with a VX5/6/7 power cable.
Caution:
! Caution:
! Note:
When a DC power cable that is eight feet or longer is in a 12V application, there may be an excessive voltage drop over the longer cable. If this occurs, a new power cable is required. Do not use this adapter with AC power supplies originally designed for the 1380, 1390, VX1, VX2 or VX4. These power supplies do not have sufficient power for the VX5.
For more information on the 12-80V DC direct, UPS battery pack and extension cable connections please refer to the appropriate section earlier in this manual.
How To Connect Power Adapter Cable
VX5 User’s Guide
1.
The VX5 must be turned off and the power cable must be UNPLUGGED from the VX5.
2.
Attach the smaller end of the Power Adapter Cable to the VX1/2/4 power cable by aligning the water-tight connector pins to the power cable connector. Push down on the water-tight connector and twist it to fasten securely.
3.
Connect the larger end of the Power Cable directly to the computer or to a UPS battery pack, as desired. Please refer to the appropriate section earlier in this manual for UPS battery pack connection details.
E-EQ-VX5OGWW-F-ARC
Page 81
Fuse Replacement for the VX5
71
Fuse Replacement for the VX5 The VX5 uses a 100V, 10A time delay (slow blow), high current interrupting rating fuse that is externally accessible and user replaceable. Should it need replacement, replace with same size, rating and type of fuse – Littlefuse 0234010 or Optifuse MSC-10A (5x20mm).
C
UL US
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
®
CAUTION: For continues protection against risk of fire, replace only with same type and rating of fuse.
This Class A digital apparatus complies with Canadian ICE-003. Cet appareil numérique de la Classe A est confirme là norme NMB-003 du Canada
ATTENTION: Pour ne pas compromette la preotection contre les risques d'incendie, remplacer par un fusible de mêmes types de mêmes caractéristques nominales.
PRODUCT OF U.S.A. U.S. PATENT 5862393
1. Fuse AUDIO INPUT: 12-80VDC 6A 72W
ETHERNET / USB
2. Twist in this direction to remove
T10A, 125V
3. Twist in this direction to insert
1
2
3
Figure 71 Fuse Replacement 1.
Turn the VX5 off and disconnect the power cable from the VX5. Caution:
Fuse has voltage on it even when power is off. Always disconnect input power before changing fuse.
! 2.
While holding the VX5 over a level surface, push the fuse cover in and twist it one quarter turn counterclockwise. A flat head screwdriver may be used to twist the fuse cover.
3.
Remove the fuse.
4.
Discard the fuse and place a new fuse in the holder.
5.
Push the fuse in and twist it clockwise one quarter turn.
6.
Reconnect the power cable to the VX5.
E-EQ-VX5OGWW-F-ARC
VX5 User’s Guide
Page 82
72
Strain Relief Cable Clamps
Strain Relief Cable Clamps Equipment Required: Phillips screwdriver (not supplied by LXE) There are four strain relief cable clamps secured to the bottom of the VX5. Use the strain relief clamps to secure audio, power, and I/O cables attached to the VX5.
IP66
!
LISTED I.T.E.
REFER TO MANUAL
N107
C
UL US ®
E-130794
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
This Class A digital apparatus complies with Canadian ICE-003. Cet appareil num érique de la Classe A est confirme là norme NMB-003 du Canada
PRODUCT OF U.S.A. U.S. PATENT 5862393
CAUTION: For continues protection against risk of fire, replace only with same type and rating of fuse. ATTENTION: Pour ne pas compromette la preotection contre les risques d'incendie, remplacer par un fusible de mêmes types de mêmes caractéristques nominales.
AUDIO INPUT: 12-80VDC 6A 72W
COM1 / SCANNER
COM2/3
KEYBOARD / MOUSE
ETHERNET / USB
T10A, 125V
Figure 72 Strain Relief Cable Clamps 1.
Remove the strain relief clamp from the bottom of the VX5 by turning the screw counterclockwise. Put the screw aside in a safe location.
2.
Slide the strain relief clamp over the cable.
Figure 73 Slide Clamp Over Cable 3.
Using a Phillips screwdriver and the screw that was removed, refasten the clamp holding the cable to the VX5. Do not stretch the cable. Leave enough slack in the cable to allow it to be connected and disconnected easily when needed.
4.
Continue in this manner until all cables are secured to the VX5.
VX5 User’s Guide
E-EQ-VX5OGWW-F-ARC